GS-4

GS-4

GS-4

Product catalog summary
Product Description
The GS-4 geothermal heating installation is a frequency-controlled brine to water heat pump. It features a frequency-controlled compressor, circulation pumps for both brine and floor heating, necessary safety equipment, and a 4 kW electrical heating element for additional heating in low temperatures. It includes a heat exchanger for free cooling, suitable for use with floor heating or fan convectors. The system is ready for direct connection to underground hoses and floor heating systems.
Usage
The GS-4 is designed for low-energy houses with a heat loss of up to 25 W/m². It is compatible only with low-temperature floor heating installations that are outdoor temperature compensated, with a maximum flow temperature of 45 °C.
Specifications
  • Electrical Connection: 3x400 V+N+PE, 13 A, 50 Hz
  • Heat Pump Output: 4 kW
  • Total Output: 8 kW
  • Dimensions: 1,007 x 670 mm (h x d)
  • Weight: 117 kg
  • Cooling Agent: R407C, 1,000 g
  • Compressor: Hitachi ASG133, variable 30-80%
  • Geothermal Side: Grundfos Alpha2 15-60-130 circulation pump, min. flow pressure 0.05 bar, max. installation pressure 10 bar
  • Central Heating Side: Grundfos Alpha2 15-60-130 circulation pump, pressure expansion tank 8 L, safety valve max. 2.5 bar
Automatic Control
The system includes an Optima 85 control with outside temperature compensation. Key settings include:
  • P1: Flow speed, set between 20 °C and 45 °C (factory setting 30 °C)
  • P2: Start hysteresis, set between 0 °C and 10 °C (factory setting 4 °C)
  • P3: Outside temperature compensation, set between 0 and 1 (factory setting 1)
  • P4: Flow temperature at -12 °C, set between 20 °C and 45 °C (factory setting 30 °C)
  • P5: Flow temperature at 20 °C, set between 20 °C and 45 °C (factory setting 20 °C)
  • P6: Free cooling activation, set between 0 and 1 (factory setting 0)
See more

Catalog excerpts

GS-4-1

DATA SHEET UK / Version 1.00 / 07.01.2014 GS-4 GEOTHERMAL HEATING INSTALLATION Product description Geothermal heating installation GS-4 is a frequency-controlled brine to water heat pump, which is equipped with a frequencycontrolled compressor with complete control, circulation pumps for both brine as the floor heating element, necessary safety equipment and a 4 kW electrical heating element, which can be connect, provided there is a need for additional heating at very low outside temperatures. It is also equipped with a heat exchanger for free cooling, so during the summer the cold liquid in the underground hoses can be used for cooling the home. This cooling function works fine in connection with floor heating or with fan convectors. The installation is ready for direct connection to underground hoses and the floor heating system. Usage Geothermal heating pump GS-4 is used for heating low-energy houses with a dimensioned heat loss of up to 25 W/m² . The geothermal heating pump can only be used for heating via a low-temperature floor heating installation, which is outdoor temperature compensated. Dimensioned flow temperatures are max. 45 °C. © Genvex A/S • The GS-4 Data Sheet reserves the right to make technical modifications

 Open the catalog to page 1
GS-4-2

Dimension diagram GS-4 Dimensions in mm: 1. Brine return 3/4” RG 2. Heat pump 3. Central heating, flow 3/4” RG 4. Circulation pump, hot 5. Circulation pump, cold 6. Electrical box 7. Safety valve 8. Heating element 9. Expansion tank, 8 L 10. Central heating, return 3/4” RG 11. Environmental pressure switch 12. Belimo motor 13. Terminal strip 14. Brine, flow 3/4” RG 15. Control panel 3/4” RG fill/drain valves have been mounted at all flow and return connections. © Genvex A/S • The GS-4 Data Sheet reserves the right to make technical modifications

 Open the catalog to page 2
GS-4-3

Control panel Electrical connection: Supply voltage: Starting current: Output, heat pump (B0/W35): Output, the heating elements: Total output: Heat pump: Dimensions (h x d): (b, M55): (b, M60): Weight: Installation site: Condensation drain: COP per EN14511, outside air: 7 °C: SCOP per EN14528: Cooling agent: Cooling agent filling: Compressor: Compressor, variable: Low pressure switch, NO/NC: High pressure switch, NO/NC: 1.007 x 670 mm 548 mm 598 mm 117 kg Min. 5o °C / max. 35 °C PA tube Ø15 mm outside 5.0 4.3 R407C 1,000 g Hitachi ASG133 30-80 % 1.5/3.0 bar w/ aut. reset 20/16 bar w/ aut. reset...

 Open the catalog to page 3

All Genvex catalogs and technical brochures

  1. COMBI 185 BP

    6  Pages

  2. ECO 400 2022

    6  Pages

  3. ECO 375

    6  Pages

  4. ECO 360 R

    6  Pages

  5. ECO 275

    6  Pages

  6. ECO 190 XL

    6  Pages

  7. GES Energy M

    3  Pages

  8. GE Energy 2

    3  Pages

  9. GE Energy 3

    3  Pages

  10. GE Premium 3

    4  Pages

  11. Vanvex R

    3  Pages

  12. Vanvex RS

    3  Pages

  13. GE Premium 2

    4  Pages

  14. GE Energy 1

    3  Pages

  15. GES Energy S

    3  Pages

Archived catalogs

  1. ECO 400 2019

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.