Types: The GE Energy 1 unit is available in both right-hand and left-hand versions, with an optional bypass that increases the unit's width by 70 mm. Without a bypass, it is delivered in a right-hand version but can be mirror-reversed.
Description: GE Energy 1 is a heat recovery ventilation unit featuring a counter flow heat exchanger with up to 95% heat recovery efficiency. It includes energy-saving fans with backward curved blades and EC motors, F7 supply air filter, G4 extract air filter, and Optima 250 control with a user-friendly panel. Options include modulating automatic bypass, water duct reheater, electric duct reheater, and preheater.
Suitability: Suitable for dwellings requiring high heat recovery and low energy consumption, delivering up to 300 m3/h air volume at 100 Pa external pressure. It can be installed outside the climate screen in dry environments down to -10°C.
Dimensions: The unit measures 580 x 1000 x 380 mm, with a bypass width of 450 mm. It requires a minimum 300 mm distance above for electrical connections.
Technical Data: The unit operates on 1 x 230 V + N + PE, 10 A, 50 Hz. It features EC motors with integrated electronics, IP 44 protection class, and a maximum motor speed of 3320 rpm. The cabinet is made of double-plated galvanized steel with 30 mm insulation.
Sound Data: Sound levels are measured at various frequencies and airflow percentages, with average sound levels provided for different measurement points.
Control Panel: Functions include setting fan speed, extended operation timer, after-heat control, main menu access, filter alarm reset, device information, and temperature setting.
Capacity and Power Consumption: Capacity lines are based on average supply and extract air volume. Power consumption is detailed for different airflow percentages, with heat recovery rates provided for specific conditions.
See more

Catalog excerpts

GE Energy 1-1

Description GE Energy 1 is a heat recovery ventilation unit equipped with a counter flow heat exchanger with a heat recovery rate up to 95%. The ventilation unit has energy saving supply air and extract air fans with backward curved fan blades and EC motors. The unit is delivered with F7 supply air filter and G4 extract air filter and a complete Optima 250 control with a nicely designed user panel. The unit can be demand controlled with the OPT250: • With the humidity control With the week program GE Energy 1 can be delivered with the following options: - Modulating automatic bypass Water duct reheater incl. motor valve Electric duct reheater with variable power levels Electric duct preheater with variable power levels *) *) Recommended by Genvex A/S at outdoor temperatures lower than -5 °C. GE Energy 1 is suitable for dwellings, where a high heat recovery rate and a low energy consumption are requested. GE Energy 1 with bypass can be delivered in a right hand or a left hand version. With a bypass the unit is 70 mm wider as a unit without a bypass GE Energy 1 can deliver an air volume of up to appr. 300 m3/h at an external pressure of 100 Pa. GE Energy 1 without bypass is delivered in a right hand version. The unit can be mirror-reversed by interchanging front and rear panels. Due to a high degree of insulation it can be installed outside the climate screen of the dwelling in dry environments down to -10 °C. Bypass: With bypass the width is 450 mm. GE Energy 1 (right hand) Dimensions in mm Minimum distance above unit for electrical connection 300 mm Fresh air Exhaust air Extract air 1 Supply air Counter flow heat exhanger Supply air fan Extract air fan Fresh air filter 2 Extract air filter Condensation tub Condensation connection Ø15 mm 12 Electrical box (on the top) Subject to technical modifications of GE Energy 1 datasheet

 Open the catalog to page 1
GE Energy 1-2

Technical data Control panel Electrical connection: 1 x 230 V + N + PE, 10 A, 50 Hz Fans: R3G 190 Motor: EC motor with integrated electronics Isolation class: B Protection class, fans: IP 44 Motor speed, max.: 3320 rpm Input power (max. per motor): 71 W Power consumption (max. per motor): 0.50 A Construction Size: (h x l x d) excl. connections 580 x 1000 x 380 mm Cabinet: Double plated galvanized steel plate with 30 mm Isolation Duct connection: Ø160 mm with double rubber ring seal Front: To parts with quick locks for filter service Back plate: Mounted with 6 mm bolts Speed (1) Use this function...

 Open the catalog to page 2
GE Energy 1-3

The capacity lines are based on an average of the supply and extract air volume in a unit. The curves indicate the average external pressure, which is available at a given airflow. Flow m3/h At a max. air volume the available pressure is 20 Pa higher with G4 (25 mm) than the displayed curves Power consumption For both fans and control. Power consumption [W] Effektverbrauch [W] Heat recovery rate Icing of the heat exchanger at low outdoor temperatures has been left out of account. 01. = Temp.: RF: THeat recovery rate [%] [% ] Temperaturwirkungsgrad Heat recovery rate, flow msupply = mextract Subject...

 Open the catalog to page 3

All Genvex catalogs and technical brochures

  1. COMBI 185 BP

    6  Pages

  2. ECO 400 2022

    6  Pages

  3. ECO 375

    6  Pages

  4. ECO 360 R

    6  Pages

  5. ECO 275

    6  Pages

  6. ECO 190 XL

    6  Pages

  7. GES Energy M

    3  Pages

  8. GE Energy 2

    3  Pages

  9. GE Energy 3

    3  Pages

  10. GE Premium 3

    4  Pages

  11. Vanvex R

    3  Pages

  12. Vanvex RS

    3  Pages

  13. GS-4

    3  Pages

  14. GE Premium 2

    4  Pages

  15. GES Energy S

    3  Pages

Archived catalogs

  1. ECO 400 2019

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.