COMBI 185 BP
1 / 6Pages

Catalog excerpts

COMBI 185 BP - 1

Combi 185 BP • Supplies fresh air and domestic hot water for the entire family • Contributes to the heating of the home through the supply air • Automatic summer bypass Combi 185 BP is a complete unit that consists of a ventilation and a tank segment containing a high-performance counterflow heat exchanger with a heat recovery factor of up to 95%, a hot-water tank with a capacity of 185 litres and a built-in heating coil designed for connection to a solar collector or central heating, a combination heat pump for simultaneous heating of supply air and domestic hot water, as well as energy-efficient supply air and extract air fans with backwards-curved blades and EC motors. The standard unit includes an G4 supply air and a G4 extract air filter and a complete OPT312 control unit with a stylishly designed control panel. Combi 185 BP is used as a ventilation heat pump in dwellings that require a high heat recovery factor and low energy consumption, while using the recovered energy from the exhaust air for heating the home's supply air and domestic hot water. Energy is first recovered by the counterflow heat exchanger, upon which residual energy is recovered by the heat pump. Combi 185 BP can produce a max. air volume of approx. 320 m3/h at 100 Pa. The unit can be used for homes with an area of up to approx. 300 m2 with an air change of 0.30 l/s per m2 of heated floor area assuming there are no requirements for max. power consumption. Types • Combi 185 BP S: Small compressor • Combi 185 BP LS: Large compressor For the Optima 301/312, a control panel called Optima Design can be purchased. Optima Design is a stylish white control panel that provides access to the most important functions via a simple user interface with push buttons. Please note that displays are sold separately.

Open the catalog to page 1
COMBI 185 BP - 2

11. Cold water inlet 3/4” RG 22. Counterflow heat exchanger Electrical connection 13. Connection to heating coil 3/4” RG Condensation tray 14. Connection to heating coil 3/4” RG 1 kW electric heating element Condenser coil 10. High-pressure pressure switch

Open the catalog to page 2
COMBI 185 BP - 3

Technical data COMBI 185 BP Electrical connection Without electric heating coil With electric heating coil (max. 1.2 kW) Fans with directly coupled motor Motor R3G 190 EC motor with integrated electronics Insulation class Protection class Motor data (max. per motor) Power input (max. per motor) Power consumption (max. per motor) Speed control Heating pump's working range Compressor Min. air volume 0.50A Each of the fans can be set steplessly to all 3 speeds individually. -15°/+35°C NE 6170Z / NE 6210Z 100 m3/h / 150 m3/h (S/LS) Average output Average input power Overall dimensions: (h x l x...

Open the catalog to page 3
COMBI 185 BP - 4

Functional diagram Sensors T1: Supply air T2D: Room display T2S: Extract air T3: Fresh Air T4: Discharge air T5: Before cooling coil T6: Cooling coil T7: Tank, top T8: Tank, bottom T9: Solar collector Evaporator (cooling coil) Counter current heat exchanger T1 Condenser (heating coil) Control panel MA6 (equalisation valve) MA5 (equalisation valve) Solenoid valves MA2: Roomheating MA3: Domestic hotwater heating MA4: Defrost evaporator MA5: purge valve (roomheating) MA6: purge valve (DHW) High-pressure pressure switch Drier filter Solar collector Condenser externally on tank Heating coil Vv...

Open the catalog to page 4
COMBI 185 BP - 5

Capacity Capacity lines are based on the average of supply air and discharge air volumes in a unit. The curves indicate the average external pressure available at a given air volume. SFP-curves are reduced by 10 Pa using PET exchanger and 15 Pa using F7 filter at the fresh air intake. SFP factors COMBI 185 BP – measured pursuant to EN13141-7 (G4/G4:ALU) Pa Temperature efficiency "Dry" temperature efficiency pursuant to EN 308 and in the event of identical air flow on the fresh air and discharge air side. The icing of the heat exchanger at low outdoor temperatures has not been taken into...

Open the catalog to page 5
COMBI 185 BP - 6

Acoustic data 1. Measured at 40% of max. speed, with compressor in operation Measuring point 2. M easured at 70% of max. speed, with compressor in operation 3. M easured at 100% of max. speed, with compressor in operation Automatic control unit Control panel Combi 185 is shipped with a complete Optima 312 automatic control unit. Optima 312 is set to factory setting, which means that the installation is ready to run without setting up the operating menue. The factory setting is only a basic setting which should be changed to the individual operational needs and requirements of each...

Open the catalog to page 6

All Genvex catalogs and technical brochures

  1. ECO 400 2022

    6 Pages

  2. ECO 375

    6 Pages

  3. ECO 360 R

    6 Pages

  4. ECO 275

    6 Pages

  5. ECO 190 XL

    6 Pages

  6. GES Energy M

    3 Pages

  7. GE Energy 2

    3 Pages

  8. GE Energy 3

    3 Pages

  9. GE Premium 3

    4 Pages

  10. Vanvex R

    3 Pages

  11. Vanvex RS

    3 Pages

  12. GS-4

    3 Pages

  13. GE Premium 2

    4 Pages

  14. GE Energy 1

    3 Pages

  15. GES Energy S

    3 Pages

Archived catalogs

  1. ECO 400 2019

    20 Pages