Fire-Rated Glass
41Pages

{{requestButtons}}

Catalog excerpts

Fire-Rated Glass - 1

Fire-Rated Glass Fire-Resistive Pyran® Platinum

Open the catalog to page 1
Fire-Rated Glass - 2

aaaadwai ANTI-REFLECTIVE m INTERIOR SEE WHAT GLASS CAN DO GGI nwsmrilTAI S* entrance systems ^UI^UIVSl IML^S|_w-jigRAILINGS - <iZ ANTIQUE MIRRORgfiSSPECIALTY XTERIOR Z O ARCHITECTURAL 2 8 OVERSIZED Features & Benefits • Manufactured by AGC for 45 minute fire rating with hose stream • Multi-laminated glass with intumescent interlayers • Designated on drawings and in specifications as Pyrobel 45 • Tested for use as door lites and 48” x 96” fixed lites in accordance with ASTM E119, NFPA 80, NFPA 257, NFPA 252, UL 9, UL 10B, and UL 10C • Tested to ANSI Z97.1 and CPSC 16CFR 1201 to meet maximum...

Open the catalog to page 2
Fire-Rated Glass - 3

Product Guidelines LISTINGS Testing completed by Intertek/Warnock-Hersey and UL LABELING All products are labeled bearing the manufacturers name, testing laboratory, rating and safety standards. INSTALLATION All systems require 1/4” x thickness of glass x 3” calcium silicate setting blocks placed at sill quarter points. Each lite of Pyrobel must be inspected prior to installation for damage including review of edge protecting tape. (DO NOT INSTALL GLASS THAT HAS BEEN DAMAGED.) Pyrobel must be glazed with 1/8” x 1/2” closed cell foam glazing tape. Exterior glazing must have PVB side facing...

Open the catalog to page 3
Fire-Rated Glass - 4

aaaadwai ANTI-REFLECTIVE m INTERIOR SEE WHAT GLASS CAN DO GGI nwsmrilTAI S* entrance systems ^UI^UIVSl IML^S|_w-jigRAILINGS -„<iZ ANTIQUE MIRROR* 5SPECIALTY XTERIOR Z U ARCHITECTURAL 2 8 OVERSIZED Features & Benefits • Manufactured by AGC for 60 minute fire rating with hose stream • Multi-laminated glass with intumescent interlayers • Available in butt-glazed assembly* • Designated on drawings and in specifications as Pyrobel 60 • Tested in accordance with ASTM E119, NFPA 80, NFPA 252, NFPA 257, UL 9, UL 10B, UL 10C and UL 263 as a transparent wall assembly using Sti/eLite™ or GGI-KwicKap™...

Open the catalog to page 4
Fire-Rated Glass - 5

Maximum structural load performance (wind load-ASTM E330) of Pyrobel-60-25 is 1119.1 Ibs./sq. ft. LISTINGS Testing completed by Intertek/Warnock-Hersey and UL LABELING All products are labeled bearing the manufacturers name, testing laboratory, rating and safety standards. INSTALLATION All systems require 1/4” x thickness of glass x 3” calcium silicate setting blocks placed at sill quarter points. Each lite of Pyrobel must be inspected prior to installation for damage including review of edge protecting tape. (DO NOT INSTALL GLASS THAT HAS BEEN DAMAGED.) Pyrobel must be glazed with 1/8” x...

Open the catalog to page 5
Fire-Rated Glass - 6

SEE WHAT GLASS CAN DO GGI O^SnirZITAI S i ENTRANCE SYSTEMS m^lll^uiul I ML^g|_w-jig RAILINGS MazPRINTINGzs3oxtiSpicTURE — Onj-j BACK PAINTED OF d Z^FPAMF <iZ ANTIQUE MIRRORS£ SSSPECIALTY U ARCHITECTURAL OVERSIZED Features & Benefits • Manufactured by AGC for 90 minute fire rating with hose stream • Multi-laminated glass with intumescent interlayers • Designated on drawings and in specifications as Pyrobel 90 • Tested in accordance with ASTM E119, NFPA 80, NFPA 252, NFPA 257, UL 9, UL 10B, UL 10C and UL 263 as a transparent wall assembly using GGI-PyroFramesTM or GGI-KwicKapTM and in...

Open the catalog to page 6
Fire-Rated Glass - 7

Maximum structural load performance (wind load-ASTM E330) of Pyrobel-90-37 is 512.4 Ibs/sq. LISTINGS Testing completed by Intertek/Warnock-Hersey and UL LABELING All products are labeled bearing the manufacturers name, testing laboratory, rating and safety standards. INSTALLATION All systems require 1/4” x thickness of glass x 3” calcium silicate setting blocks placed at sill quarter points. Each lite of Pyrobel must be inspected prior to installation for damage including review of edge protecting tape. (DO NOT INSTALL GLASS THAT HAS BEEN DAMAGED.) Pyrobel must be glazed with 1/8” x 1/2”...

Open the catalog to page 7
Fire-Rated Glass - 8

SEE WHAT GLASS CAN DO GGI 010 £ n Ifi IT A I Si ENTRANCE SYSTEMS !^lll^UIV3l IRAILINGS ** • ?T 5 D DIM TIM2 S ^ 5 E h 8 “T:°r'J^E.L?jlLTl2 m E - }” < 12 ANTIQUE MIRROR* SSPECIALTY 01 EXTERIOR Z U ARCHITECTURAL g 5 OVERSIZED Features & Benefits • Manufactured by AGC for 120 minute fire rating with hose stream • Multi-laminated glass with intumescent interlayers • Available in butt-glazed assembly* • Designated on drawings and in specifications as Pyrobel 120 • Tested in accordance with ASTM E119, NFPA 80, NFPA 252, NFPA 257, UL 9, UL 10B, UL 10C and UL 263 as a transparent wall assembly...

Open the catalog to page 8
Fire-Rated Glass - 9

Maximum structural load performance (wind load-ASTM E330) of Pyrobel 120 is 512.4 Ibs/sq. ft. LISTINGS Testing completed by Intertek/Warnock-Hersey and UL LABELING All products are labeled bearing the manufacturers name, testing laboratory, rating and safety standards. INSTALLATION All systems require 1/4” x thickness of glass x 3” calcium silicate setting blocks placed at sill quarter points. Each lite of Pyrobel must be inspected prior to installation for damage including review of edge protecting tape. (DO NOT INSTALL GLASS THAT HAS BEEN DAMAGED.) Pyrobel must be glazed with 1/8” x 1/2”...

Open the catalog to page 9
Fire-Rated Glass - 10

SEE WHAT GLASS CAN DO GGI nwsmrilTAI S* entrance systems ^UI^UIVSl IML^S|_w-jigRAILINGS 0< EXTERIOR Zu ARCHITECTURAL OVERSIZED Narrow profile, roll-formed steel framing manufactured for 45 to 120 minute fire rating applications with hose stream Designated on drawings and in specifications as GGI-PyroFrames™ Tested in accordance with UL 263, ASTM E119, and NFPA 251 as a transparent wall assembly with Pyrobel glazing Available with narrow stile GGI-PyroDoors™ Internal and external surface protection provided by Sendzimir galvanizing for maximum durability in combination with painted...

Open the catalog to page 10
Fire-Rated Glass - 11

System fasteners: -Zinc coated 1.4301 stainless steel according to DIN EN17440. (Equivalent to 304 quality to AISI standards) System gaskets: -Non cellular elastomer compound to DIN EN7863. (Equivalent to BS3734) Performance classifications according to EN13830 : 2003: -Water Intrusion Resistance 1650 Pa / Air Permeability >600 Pa / Sound Insulation up to 47 dB Product Guidelines LISTINGS Testing completed by Intertek/ Warnock-Hersey LABELING All products are labeled bearing the manufacturers name, testing laboratory, rating and safety standards. INSTALLATION GGI-PyroFrames™ have been...

Open the catalog to page 11

All General Glass International catalogs and technical brochures

  1. ENDUROSHIELD

    4 Pages

  2. Shower doors

    3 Pages

  3. Alice

    11 Pages

  4. Kaleidoscope

    5 Pages