Product Overview: The GENEBRE 3917 is a digital thermostat designed for both heating and cooling applications. It is programmable for 7 days and is suitable for surface mounting. The device is CE and Rohs approved, ensuring compliance with European safety and environmental standards.
Technical Specifications: The thermostat operates on two AAA batteries and features a relay contact of 250 VAC (0.25A). It has a set point range of 5ºC to 35ºC with 0.5ºC increments, and functions effectively in ambient temperatures from 0ºC to 50ºC with a relative humidity of 85%. The device includes a white backlight and an NTC 10K sensor, with an accuracy of ±1ºC and an IP30 protection class. The housing is made from ABC+PC materials.
Display Features: The display indicates the weekday, clock, child lock status, heating and cooling modes, manual and program modes, away mode, and open window mode. It also shows the current program period.
Child Lock and Mode Selection: The child lock feature prevents accidental changes by locking the buttons when the backlight is off. Users can switch between heating and cooling modes, as well as manual and program modes, using the SET and PRG buttons.
Clock and Weekday Setting: Users can set the clock and weekday by holding the SET button for 5 seconds and adjusting the settings using the + and - buttons.
7-Day Programmable Setting: The thermostat allows for detailed scheduling, including setting the weekday, period, start time, and temperature. An example schedule is provided for weekdays and weekends.
Open Window Detect Function (OWD): This feature automatically stops heating when a sudden temperature drop is detected, typically due to an open window or door. The system resumes normal operation after 30 minutes unless interrupted by a button press.
Parameter Settings: Users can adjust various parameters such as temperature calibration, set point limits, frost protection temperature, dead zone, display temperature, child lock, and OWD settings. A factory reset option is also available.
Installation and Wiring: The document includes a wiring diagram and installation dimensions for proper setup.
Disposal Instructions: At the end of its life, the thermostat should not be disposed of as urban waste. It must be taken to a specialized waste collection center to prevent environmental and health risks and to facilitate material recycling.
See more

Catalog excerpts

3917-1

GENEBRE S.A. · Avda. Joan Carles I, 46-48 · EDIFICIO GENEBRE Tel. +34 93 298 80 00/01 · Fax +34 93 298 80 06 08908 L’HOSPITALET DE LLOBREGAT Barcelona (Spain) e-mail: [email protected] internet: http://www.genebre.es Art.: 3917 Termostato digital frio-calor / Heat-Cool Digital Thermostat 1. 2. 3. 4. Características Termostato de frio / calor Programable para 7 días Montaje en superficies Homologación CE, Rohs Datos técnicos Alimentación: 2 baterías AAA Contacto de relé: 250 VAC (0.25A) Rango de ajuste: 5ºC – 35ºC (incremento 0.5 ºC) Temperatura ambiente: 0ºC ~ 50ºC Humedad relativa: 85% Retroiluminación: Blanca Sensor: NTC 10K Precisión: ± 1ºC Grado de protección: IP30 Carcasa: ABC+PC Features Heat / cool thermostat 7 days programmable Surface mounting CE, Rohs approved Technical Data Power supply: 2*AAA battery Relay contact: 250 VAC (0,25A) Set Point Range: 5ºC – 35ºC (0.5 ºC increase) Ambient: 0ºC ~ 50ºC Relative Humidity: 85% Backlight: White Sensor: NTC 10K Accuracy: ± 1ºC Protection Class: IP30 Housing: ABC+PC

 Open the catalog to page 1
3917-2

GENEBRE S.A. · Avda. Joan Carles I, 46-48 · EDIFICIO GENEBRE Tel. +34 93 298 80 00/01 · Fax +34 93 298 80 06 08908 L’HOSPITALET DE LLOBREGAT Barcelona (Spain) e-mail: [email protected] internet: http://www.genebre.es Indicación Dia de la semana Reloj Bloqueo infantil Calefacción encendida Modo manual Modo de programación Modo ausente Modo calefacción Modo frio Frio ON Modo de ventana abierta Periodo de programación actual Bloqueo infantil Con el bloqueo infantil ENCENDIDO (consulta el menú 11 de ajuste de parámetros), los botones se bloquean al apagarse la luz de fondo. Mantenga presionado el...

 Open the catalog to page 2
3917-3

GENEBRE S.A. · Avda. Joan Carles I, 46-48 · EDIFICIO GENEBRE Tel. +34 93 298 80 00/01 · Fax +34 93 298 80 06 08908 L’HOSPITALET DE LLOBREGAT Barcelona (Spain) e-mail: [email protected] internet: http://www.genebre.es Ajuste del reloj y día de la semana Mantén pulsado el botón SET durante 5s, ajusta el reloj (día de la semana en min-hora) pulsando los botones + y - , cada pulsación del botón SET pasa al siguiente ajuste. Menú 01 02 03 04 Clock & Weekday Setting Press and hold SET button for 5s, set the clock (Min-Hour-Weekday) by pressing + and – button, each press of SET button will go to the...

 Open the catalog to page 3
3917-4

GENEBRE S.A. · Avda. Joan Carles I, 46-48 · EDIFICIO GENEBRE Tel. +34 93 298 80 00/01 · Fax +34 93 298 80 06 08908 L’HOSPITALET DE LLOBREGAT Barcelona (Spain) e-mail: [email protected] internet: http://www.genebre.es Ajuste de parámetros En modo apagado, mantén pulsado el botón SET y el botón + durante 6 segundos para entrar en ajuste de parámetros. Cada vez que pulses el botón SET pasaras al ajuste del dia siguiente. Ajusta el valor pulsando el botón + o Menu 01 02 03 05 09 Descripción / Description Calibración de temperatura del sensor interno Temp. calibration for internal sensor Punto de...

 Open the catalog to page 4
3917-5

GENEBRE S.A. · Avda. Joan Carles I, 46-48 · EDIFICIO GENEBRE Tel. +34 93 298 80 00/01 · Fax +34 93 298 80 06 08908 L’HOSPITALET DE LLOBREGAT Barcelona (Spain) e-mail: [email protected] internet: http://www.genebre.es ESQUEMA DE CABLEADO / WIRING DIAGRAM INSTALACION Y DIMENSIONES / INSTALLATION AND DIMENSION

 Open the catalog to page 5
3917-6

GENEBRE S.A. · Avda. Joan Carles I, 46-48 · EDIFICIO GENEBRE Tel. +34 93 298 80 00/01 · Fax +34 93 298 80 06 08908 L’HOSPITALET DE LLOBREGAT Barcelona (Spain) e-mail: [email protected] internet: http://www.genebre.es Información importante para el correcto desecho del producto Al final de su vida útil, el producto no se puede desechar como residuo urbano. Se debe llevar a un punto de recogida de residuos, establecido por la autoridad competente o por proveedores especializados en este servicio. Reciclar un producto eléctrico o electrónico de forma adecuada evita las consecuencias negativas para...

 Open the catalog to page 6

All Genebre catalogs and technical brochures

  1. 1179 04

    5  Pages

  2. 1766 00

    3  Pages

  3. PA1051

    4  Pages

  4. 100206 45

    1  Page

  5. 100208 43

    3  Pages

  6. 100208 45

    1  Page

  7. 68917 45

    2  Pages

  8. 1155 04

    4  Pages

  9. B64113 41

    3  Pages

  10. 1636 41

    4  Pages

  11. 9908 0284

    3  Pages

  12. FRV61207 44

    5  Pages

  13. 8067

    2  Pages

  14. 6085

    3  Pages

  15. 70500

    3  Pages

  16. 3932

    4  Pages

  17. 3316E

    3  Pages

  18. 3780

    3  Pages

  19. 3065

    2  Pages

  20. 3094

    2  Pages

  21. 3860

    2  Pages

  22. INDUSTRIAL LINE

    152  Pages

  23. PUBLIC TAPS

    124  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.