GEBERIT SUPERTUBE THE SPACE GAINING SYSTEM
Open the catalog to page 1MORE SPACE AFFORDED BY OPTIMISED HYDRAULICS • More living and floor space • Simple planning and installation • Smaller, consistent pipe diameter • No additional ventilation pipes • Horizontal pipelines wi thout slope* The ingenious, flow-optimised Geberit SuperTube technology creates a continuous column of air in the discharge pipe, meaning a parallel ventilation pipe installation is no longer required. The pipelines with smaller dimensions, which cope entirely without ventilation pipes, require significantly smaller pipe ducts. What’s more, the horizontal pipelines can be laid to a length of...
Open the catalog to page 2SOPHISTICATED HYDRAULICS EVERYTHING AN EFFICIENT DRAINAGE SYSTEM NEEDS GEBERIT SUPERTUBE This technology facilitates a consistent discharge pipe with a single pipe dimension. There is no need for a ventilation pipe and, what’s more, the horizontal pipeline can even be laid to a length of up to 6 metres without a slope. With its maximum discharge capacity of 12 l/s and a consistent pipe diameter of d110, Geberit SuperTube offers a comparable performance to a conventional system with considerable reductions in space and material requirements. TAKING THE GEBERIT HDPE SOVENT FITTING TO THE NEXT LEVEL...
Open the catalog to page 3(l) The outflowing water is set in rotation in the Geberit HDPE Sovent fitting. The annular flow becomes a ayered flow in the Geberit HDPE BottomTurn bend. The layered flow becomes an annular flow once again in the Geberit HDPE BackFlip bend FITTINGS THAT PUT A WHOLE NEW SPIN ON THINGS The Geberit SuperTube technology is based on the perfect interplay between four system components. Three clever fittings coupled with the tried-and-tested Geberit HDPE discharge pipe with its high load-bearing capacity combine to create an innovative hydraulic solution that also brings clear additional benefits....
Open the catalog to page 4HIGH AMBITIONS CALL FOR A STRONG PARTNER Finding cost-effective and reliable drainage systems for high-rise buildings often presents a challenge for building owners, sanitary engineers and plumbers alike. With its consistent research into hydraulics and its own, in-house product development, Geberit is raising the bar not only on a technical level, but also when it comes to service. Partnership and reliability are core values that our customers around the world can expect from us. Whether you are looking for planning support, help with invitations to tender, or building site support, the Geberit...
Open the catalog to page 5GEBERIT HYDRAULIC COMPETENCE SIMULATIONS AND TESTS The Geberit researchers start by using computational fluid dynamics (CFD) to establish potential development variations on a virtual basis in order to filter out optimal solutions for further development within the laboratory environment. The in-house drainage tower, which has been part of the test laboratory for over 50 years, then offers the opportunity to subject the new developments to all relevant hydraulic tests under real-life conditions in a subsequent step. It is only once the prototypes have successfully confirmed the simulation results...
Open the catalog to page 6LOBBY 33, GUADALAJARA, MEXICO INNOVATIVE TECHNOLOGY FOR GREATER ENVIRONMENTAL AWARENESS "Space savings are always a crucial consideration. As far as investors are concerned, maximising the usable selling space is paramount. Cost-effectiveness also has a role to play, although this is not always clear when comparing the material costs of different systems." Aldo Reyes Artexa in Mexico PROJECT OVERVIEW • Project Developer: Numel Constructora Integral • Architect: Carlos Santoscoy • Owner: Promodesa Habitat • Plumber: Servi • Height: 140 m • Floors: 30 • Completion: 2018 THE CHALLENGE The Lobby...
Open the catalog to page 7SECON NILE TOWERS, CAIRO, EGYPT SAVING 1.1M EUR BY SAVING 50% SPACE "Geberit Sovent was chosen because of its performance, technical solution, maintenance and the ways of installation. Moreover its price was moderate considering the necessary modifications in our project." Hossam Abu Zeid, Head of Plumbing & Fire Department of EHAF • Cutting down the number of stacks from 162 to 27 • Original shaft size: 0.36 m2 • Shaft with optimal Sovent planning: 0.18 m2 • Optimal room extraction per bathroom 0.18 m2 • 54 bathrooms per floor: gaining 4.86 m2 • 23 floors: gaining 111,78 m2 PROJECT OVERVIEW...
Open the catalog to page 8Geberit Sales Ltd Geberit House Edgehill Drive Warwick Warwickshire CV34 6NH T01926516800 E [email protected] Literature hotline: 0800 007 5133 www.geberit.co.uk int.en 21164-19/345 © by Geberit International Sales AG
Open the catalog to page 91 Page
1 Page
1 Page
141 Pages
72 Pages
13 Pages
13 Pages
72 Pages
11 Pages
11 Pages
2 Pages
19 Pages
15 Pages
24 Pages
6 Pages
8 Pages
22 Pages
8 Pages
16 Pages
5 Pages
18 Pages
2 Pages
8 Pages
2 Pages
27 Pages
20 Pages
13 Pages
22 Pages