1. Catalogs
  2. Galletti
  3. V-IPER 50 - 380 kW
video corpo

V-IPER 50 - 380 kW

V-IPER 50 - 380 kW
1 / 12 PagesView full catalog

V-IPER 50 - 380 kW

Product catalog summary
Overview: The document introduces the Galletti V-IPER range of chillers and heat pumps, highlighting their high efficiency and advanced technology for HVAC systems. The range includes 20 air-water models with cooling capacities from 50 to 380 kW, using R410A refrigerant and multiscroll units.
Specifications: The V-IPER range is Eurovent Class A certified for both chiller and heat pump modes. It features trio solutions with three compressors on a circuit for enhanced efficiency at partial loads. The units are configurable for low-noise operation and have advanced control systems for continuous monitoring and connectivity.
Key Features: V-IPER units offer intelligent water flow modulation, an extended operating range, and a modular structure with V configuration condensing coils. They include electronic valves for optimized operation and reduced power consumption. The Hydro Smart Flow system allows for counterflow heat exchange, improving efficiency across seasons.
Components and Accessories: The units come with accessories such as metal filters, hydro smart flow kits, remote controls, and sound insulation options. They feature microchannel condensing coils with epoxy and UV treatment for durability in harsh environments.
Functions: The V-IPER range includes primary pump management, economy mode for low-noise operation, continuous data storage, variable water flow management, and dynamic superheating management, contributing to increased efficiency and reduced operational costs.
Technical Data: Detailed specifications include power supply, cooling and heating capacities, energy efficiency ratios (EER and ESEER), water flow rates, pressure drops, and sound power levels. The units are designed for efficient operation across various climatic conditions.
Specifications:
  • Sound Power Level: 80 to 93 dB(A) depending on the model.
  • Weight: Transport weight from 938 kg to 4329 kg; operating weight from 1288 kg to 5079 kg.
  • Power Supply: 400 V, 3-phase, 50 Hz.
  • Cooling Capacity: 124 kW to 367 kW.
  • Heating Capacity: 126 kW to 379 kW.
  • Efficiency Ratings: EER from 3.10 to 3.20, COP from 3.24 to 3.33, with seasonal efficiency classes A to A++.
  • Water Flow and Pressure: Water flow rates from 21395 l/h to 65672 l/h, pressure drops between 23 kPa and 48 kPa.
Procedures and Standards:
  • Cooling and heating capacities measured under UNI EN 14511:2013 conditions.
  • Sound power levels measured according to UNI EN ISO 9614.
  • EUROVENT certification ensures compliance with European standards.
Dimensional Drawings:
  • Includes diagrams for various models, indicating water drainage, inlet and outlet connections, vibration dampers, and electric control boards.
Key Recommendations:
  • Ensure proper installation of Victaulic connections and vibration dampers to maintain system integrity.
  • Follow specified power supply requirements to avoid operational issues.
See more

Catalog excerpts

V-IPER 50 - 380 kW-1

Outdoor monobloc units A V-IPER 50 - 380 kW 0). R-4iuA A-Class Scroll R-410A Cooling only Cooling / Monobloc Axial fans compressor refrigerant Heating unit ✓ Class A in chiller and heat pump operating mode ✓ High efficiency under part load conditions ✓ Intelligent modulation of the water flow rate ✓ Extended operating range ✓ Possibility to configure low-noise versions ✓ Counterflow solutions in every operating mode V-IPER heat pumps and water chillers are designed for heating or cooling the water to be used in air-conditioning systems for residential, commercial or industrial use. Its high efficiency ensures a considerable reduction in consumption and the ability to operate in various weather conditions. Technology and efficiency in Galletti's new solution Viper is Galletti's new high efficiency range, featuring Galetti's most advanced technology in the R410A multiscroll units used in HVAC. The range consists of 20 air-water models available as chiller and heat pump, with cooling capacities from 50 to 380 kW. The range's main strongpoint is its high efficiency, not only as time efficiency (Class A Eurovent in chiller and heat pump mode) but especially as seasonal efficiency, aiming to permanently reduce annual energy consumption. In order to increase the efficiency at partial loads, much of the range is comprised of trio solutions (3 compressors on a circuit); furthermore, Viper employs components and adjustment logic that make it possible to manage the water-side flow rate modulation. The range allows high configurability from an acoustic point of view, having a wide range of accessories designed to reduce noise emissions. The advanced control, always present in the whole range, allows a continuous monitoring of the operating parameters, advanced adjustment logics, and connectivity. The modular structure with V configuration condensing coils is designed to optimize air-side heat exchange, to ensure structural strength with a reduced footprint, and to maintain maximum accessibility to the basic components. Chillers and heat pumps - V-IPER

 Open the catalog to page 1
V-IPER 50 - 380 kW-2

The models are completely configurable by selecting the version and the options. To the right is shown an example of configuration. To verify the compatibility of the options, use the selection software or the price list. AVAILABLE VERSIONS Cooling only versions Versions with reversible heat pump VPR..CS0A 400V-3N-50Hz power supply + circuit breakers VPR..HS0A 400V-3N-50Hz power supply + circuit breakers VPR..CS1A 230V-3-50Hz power supply + circuit breakers VPR..HS1A 230V-3-50Hz power supply + circuit breakers VPR..CS2A 400V-3-50Hz power supply + transformer + circuit breakers VPR..HS2A 400V-3-50Hz...

 Open the catalog to page 2
V-IPER 50 - 380 kW-3

MAIN COMPONENTS Structure The range is designed modularly, replicating the optimized structure of V configuration condensing coils and fans. Its design ensures stability, sturdiness even during the most critical phases (such as transportation), and maximum accessibility to components in every Viper unit. Electronic valve Supplied as a standard feature, it allows optimization of operation and reduction of power consumption as a result of faster transients. Low noise execution The units can be supplied in a low-noise version, with noise-canceling headsets, acoustical enclosure for the compressors,...

 Open the catalog to page 3
V-IPER 50 - 380 kW-4

V-IPER Chillers and heat pumps FUNCTIONS Variable water flow The advanced controller allows the management of the variable flow on the primary circuit, thus ensuring an increase in cooling cycle efficiency, reduced pumping costs, and an overall increase in seasonal energy efficiency. The plate heat exchanger has an internal configuration especially designed to operate with modulation of flow rate up to 30% of nominal flow. Economy – low-noise operation This feature allows, on the basis of time periods or clean contact, a reduction in the maximum speed of the fans and the compressors that can...

 Open the catalog to page 4
V-IPER 50 - 380 kW-5

Rated technical data of V-IPER C water chillers Chillers and heat pumps - V-IPER V-IPER..CS (1) Water temperature 12/7 °C, outdoor air temperature 35 °C (UNI EN 14511:2013) (3) Sound power level measured according to UNI EN ISO 9614 (E) EUROVENT certified data

 Open the catalog to page 5
V-IPER 50 - 380 kW-6

V-IPER Chillers and heat pumps Rated technical data of V-IPER C water chillers V-IPER..CS (1) Water temperature 12/7 °C, outdoor air temperature 35 °C (UNI EN 14511:2013) (3) Sound power level measured according to UNI EN ISO 9614 (E) EUROVENT certified data

 Open the catalog to page 6
V-IPER 50 - 380 kW-7

AGalletti Rated technical data of V-IPER H heat pumps Chillers and heat pumps - V-IPER GAPCBX171A

 Open the catalog to page 7
V-IPER 50 - 380 kW-8

Rated technical data of V-IPER H heat pumps V-IPER..HS (1) Water temperature 12/7 °C, outdoor air temperature 35 °C (UNI EN 14511:2013) (2) Water temperature 40 / 45°C, outdoor air temperature 7°C B.S. / 6°C B.U. (14511:2013) (3) Sound power level measured according to UNI EN ISO 9614 (E) EUROVENT certified data * Seasonal energy efficiency class for LOW TEMPERATURE room heating under AVERAGE climatic conditions [EUROPEAN REGULATION No 811/2013]

 Open the catalog to page 8
V-IPER 50 - 380 kW-9

1 Water drainage 1/2" female 2 Water inlet Victaulic 2" 3 Water outlet Victaulic 2" Chillers and heat pumps - V-IPER GAPCBX171A

 Open the catalog to page 9
V-IPER 50 - 380 kW-10

V-IPER Chillers and heat pumps Dimensional drawings VPR 72 - 82 - 92 - 112 - 133 LEGEND 1 Water drainage 1/2" female 2 Water inlet Victaulic 2 1/2" 3 Water outlet Victaulic 2 1/2"

 Open the catalog to page 10
V-IPER 50 - 380 kW-11

Dimensional drawings LEGEND 1 Water drainage 1/2"female 2 Water inlet Victaulic 2 1/2" 3 Water outlet Victaulic 2 1/2" Chillers and heat pumps - V-IPER LEGEND 1 Water drainage 1/2" female 2 Water inlet Victaulic 4" 3 Water outlet Victaulic 4" 5 Electric control board 6 Victaulic reduction from 4"to 3" to be mounted on site 7 Water outlet only evaporator version

 Open the catalog to page 11
V-IPER 50 - 380 kW-12

Dimensional drawingsVPR276 - 306 - 336 LEGEND 1 Water drainage 1/2" female 2 Water inlet Victaulic 4" 3 Water outlet Victaulic 4" 5 Electric control board 7 Water outlet only evaporator version LEGEND 1 Water drainage 1/2" female 2 Water inlet Victaulic 4" 3 Water outlet Victaulic 4" 5 Electric control board 7 Water outlet only evaporator version

 Open the catalog to page 12

All Galletti catalogs and technical brochures

  1. EFFETTO

    4  Pages

  2. PLE

    6  Pages

  3. LCX

    16  Pages

  4. VLS

    19  Pages

  5. PLI

    6  Pages

  6. MPIDC

    6  Pages

  7. UTN 3 - 23 kW

    6  Pages

  8. Fan Coil ART-U

    10  Pages

  9. WRE

    12  Pages

  10. Fan coil FM

    4  Pages

  11. VLE

    10  Pages

  12. ACQVARIA

    6  Pages

  13. FLAT Li

    4  Pages

  14. FLAT L

    4  Pages

  15. ESTRO

    14  Pages

  16. DUCTIMAXi

    6  Pages

  17. DUCTIMAX

    6  Pages

  18. DST

    2  Pages

  19. ART-U 1

    6  Pages

  20. AREO i

    4  Pages

  21. AREO 8

    10  Pages

  22. AREO

    6  Pages

  23. EVO

    2  Pages

  24. RYT

    4  Pages

  25. IWC

    6  Pages

  26. IWCi

    4  Pages

  27. ESTRO i

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.