Catalog excerpts
Air chillers and heat pumps LCX Outdoor packaged unit LCX 55 - 360 kW LCX: wide range of models and configurability The main feature of the new LCX design is its extremely wide range: the 16 models that comprise it can be built as chiller, free cooling, or heat pump versions, in 2 different acoustic configurations, and cover a range of powers from 55 to 360 kW. The possibility of setting up different cooling circuits in units of the same power means being able to personalise efficiency levels under full or part load conditions. – 1 circuit, 2 compressors. The solution of using two compressors in a single cooling circuit increases efficiency under part load conditions, reaching ESEER/SEER and SCOP values greater than 4. – 2 circuits / 4 compressors, 4 compressors enable the unit to output power in 4 steps and adapt perfectly to the actual thermal load of the system, while reducing starting currents. Complete hydronic kits can be incorporated within the units without modifying their size and you have the option of choosing the water circulation pump. All units, irrespective of type of construction, are equipped with electronic expansion valves to maximise efficiency under part load conditions. Scroll compressor Cooling only Heating/ Cooling Packaged execution Super low noise execution available on request Electronic expansion valve Incorporable hydraulic kit Up to 4 compressors 1 or 2 cooling circuits Remote connectivity with the most common protocols Super low noise execution available on request - LCX heat pumps and water chillers are designed for heating or cooling the water to be used in air-conditioning systems for residential, commercial or industrial use.
Open the catalog to page 1MAIN COMPONENTS Structure Made in galvanised steel sheet with a polyester powder coating for outdoors. The compressor compartment is completely sealed and may be accessed on 3 sides thanks to easy-toremove panels that greatly simplify maintenance and/or inspection. Scroll compressors Heat exchanger Scroll compressors are now the best solution in terms of reliability and limiting the sound power emitted. The compressors are supplied complete with motor protection against overheating, overcurrents and excessive outlet gas temperatures. Made of generously sized aluminum ns and copper piping....
Open the catalog to page 2Air chillers and heat pumps LCX LCX CS WATER CHILLERS RATED TECHNICAL DATA LCX CS Power supply Cooling capacity Total power input EER SEER Water ow Water pressure drop Available pressure head - LP pumps Maximum current absorption Start up current Startup current with soft starter Compressors / circuits Expansion vessel volume Bu er tank volume Sound power level Transport weight unit with pump and tank Operating weight unit with pump and full tank LCX CS Power supply Cooling capacity Total power input EER SEER Water ow Water pressure drop Available pressure head - LP pumps Maximum current...
Open the catalog to page 3LCX CS WATER CHILLERS RATED TECHNICAL DATA LCX CS Power supply Cooling capacity Total power input EER SEER Water ow Water pressure drop Available pressure head - LP pumps Maximum current absorption Start up current Startup current with soft starter Compressors / circuits Expansion vessel volume Bu er tank volume Sound power level Transport weight unit with pump and tank Operating weight unit with pump and full tank Air chillers and heat pumps - LCX (1) Outdoor air temperature 35°C, water temperature 12°C / 7°C (EN14511:2022) (2) η e ciency values for heating and cooling are respectively...
Open the catalog to page 4Air chillers and heat pumps LCX LCX HS HEAT PUMPS RATED TECHNICAL DATA LCX HS Power supply Cooling capacity Total power input EER SEER Water ow Water pressure drop Available pressure head - LP pumps Heating capacity Total power input COP SCOP Heating energy e ciency class Water ow Water pressure drop Available pressure head - LP pumps Maximum current absorption Start up current Startup current with soft starter Compressors / circuits Expansion vessel volume Bu er tank volume Sound power level Transport weight unit with pump and tank Operating weight unit with pump and full tank LCX HS Power...
Open the catalog to page 5(1) Outdoor air temperature 35°C, water temperature 12°C / 7°C (EN14511:2022) (2) η e ciency values for heating and cooling are respectively calculated by the following formulas: [η = SCOP / 2,5 - F(1) - F(2)] e [η = SEER / 2,5 - F(1) - F(2)]. For further information, please refer to the technical document “ErP 2009/125/EC DIRECTIVE” in the catalogue introducing pages, or to the EN14825:2022 regulation. (3) Outdoor air temperature dry bulb 7°C / wet bulb 6°C, water temperature 30°C / 35°C (EN14511:2022) (4) Seasonal energy e ciency class for LOW TEMPERATURE room heating under AVERAGE...
Open the catalog to page 6Air chillers and heat pumps LCX LCX CL WATER CHILLERS RATED TECHNICAL DATA LCX CL Power supply Cooling capacity Total power input EER SEER Water ow Water pressure drop Available pressure head - LP pumps Maximum current absorption Start up current Startup current with soft starter Compressors / circuits Expansion vessel volume Bu er tank volume Sound power level Transport weight unit with pump and tank Operating weight unit with pump and full tank LCX CL Power supply Cooling capacity Total power input EER SEER Water ow Water pressure drop Available pressure head - LP pumps Maximum current...
Open the catalog to page 7LCX CL WATER CHILLERS RATED TECHNICAL DATA LCX CL Power supply Cooling capacity Total power input EER SEER Water ow Water pressure drop Available pressure head - LP pumps Maximum current absorption Start up current Startup current with soft starter Compressors / circuits Expansion vessel volume Bu er tank volume Sound power level Transport weight unit with pump and tank Operating weight unit with pump and full tank Air chillers and heat pumps - LCX (1) Outdoor air temperature 35°C, water temperature 12°C / 7°C (EN14511:2022) (2) η e ciency values for heating and cooling are respectively...
Open the catalog to page 8Air chillers and heat pumps LCX LCX HS HEAT PUMPS RATED TECHNICAL DATA LCX HL Power supply Cooling capacity Total power input EER SEER Water ow Water pressure drop Available pressure head - LP pumps Heating capacity Total power input COP SCOP Heating energy e ciency class Water ow Water pressure drop Available pressure head - LP pumps Maximum current absorption Start up current Startup current with soft starter Compressors / circuits Expansion vessel volume Bu er tank volume Sound power level Transport weight unit with pump and tank Operating weight unit with pump and full tank LCX HL Power...
Open the catalog to page 9All Galletti catalogs and technical brochures
-
EFFETTO
4 Pages
-
PLE
6 Pages
-
VLS
19 Pages
-
PLI
6 Pages
-
MPIDC
6 Pages
-
UTN 3 - 23 kW
6 Pages
-
FLAT S 1 - 3 kW
4 Pages
-
Fan Coil ART-U
10 Pages
-
WRE
12 Pages
-
Fan coil FM
4 Pages
-
VLE
10 Pages
-
ACQVARIA
6 Pages
-
FLAT Li
4 Pages
-
FLAT L
4 Pages
-
ESTRO
14 Pages
-
DUCTIMAXi
6 Pages
-
DUCTIMAX
6 Pages
-
DST
2 Pages
-
ART-U 1
6 Pages
-
AREO i
4 Pages
-
AREO 8
10 Pages
-
AREO
6 Pages
-
V-IPER 50 - 380 kW
12 Pages
-
Air chillers and heat pumps MPE
12 Pages
-
Air destratifiers DST
2 Pages
-
Static convector KAIMAN
2 Pages
-
galetti company profile
15 Pages
-
EVO
2 Pages
-
RYT
4 Pages
-
IWC
6 Pages
-
IWCi
4 Pages
-
ESTRO i
12 Pages