Catalog excerpts
Air conditioning fan heaters with ON/OFF motor AREO 8 - 101 kW Hygrothermal comfort in the industrial and commercial sectors In line with recent regulatory developments regarding energy efficiency, Galletti is updating its offering of fan heaters for heating and cooling systems to be used in industrial and commercial environments of any volume. The new AREO, which was designed to meet the stringent requirements of the ERP Directive, retains unchanged the distinctive aspects of the original design, that is, extreme reliability and sturdiness. AREO’s cover, which is made of pre-painted steel sheet, possesses an original design with a rounded shape that enhances its aesthetic form. The AREO range consists of 18 models that, limited to the only heating version, can be either wall mounted (horizontal air flow) or ceiling mounted (vertical air flow). The cooling version is equipped with a new system in order to collect condensation and further insulation inside the cover. The units are available in 6 sizes with 2-, 3- or 4-row heat exchangers ensuring an efficient performance with hot water supplied by a boiler or heat pump (4-row models). Vertical installation Horizontal installation (not for AERO C) Cooling (only for AERO C) PLUS » Low sound levels » Wide operating range (up to 60 °C intake air) » Axial fan with blades with an aerodynamic profile (HyBlade® technology) » Electric motor, class F, approved for continuous operation » Wide operating range (up to 60 °C intake air) AVAILABLE VERSIONS Single-phase and three-phase power supply. AREO P Fan heaters for hot water Fan heaters for hot wa- Fan heaters for steam heating, with side water ter heating, with vertical heating, with vertical waconnections. water connections, for ter connections. replacement of indoor units installed in existing systems. Fan heaters for hot water heating, equipped with air-curtain diffuser, ceiling mounted. Single phase power supplied fan heaters suitable either for heating or cooling mode, equipped with asynchronus electric motor and side water connections, wall
Open the catalog to page 1AGallettiMAIN COMPONENTS Fan drive assembly The motor and fan are a single integrated unit optimized to achieve maximum aeraulic efficiency. In fact, conformity to ERP2017 is guaranteed, even for the versions with single-phase power supply. Electric motor Tropicalized motor directly coupled to an external rotor, standard, with the following features: • equipped with internal thermal protection • windings in class F • protection rating IP54 • maintenance-free ball bearings Axial fan With blades with an optimized aerodynamic profile (HyBlade® technology), statically balanced, inserted in a...
Open the catalog to page 2(1) Water temperature 85°C / 75°C, air temperature 15°C - 100% of the max speed (2) Sound power measured according to standards ISO 3741 - 100% of the max speed
Open the catalog to page 3(1) Water temperature 85°C / 75°C, air temperature 15°C - 100% of the max speed (2) Sound power measured according to standards ISO 3741 - 100% of the max speed
Open the catalog to page 4(1) Water temperature 85°C / 75°C, air temperature 15°C - 100% of the max speed (2) Sound power measured according to standards ISO 3741 - 100% of the max speed (3) Measured at 100% ofthe max speed
Open the catalog to page 5RATED TECHNICAL DATA AREO C - COOLING MODE AREO C Fan heaters - AREO AREO C (1) Water temperature 85°C / 75°C, air temperature 15°C - max speed avaible in cooling mode (2) Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity) - max speed avaible in cooling mode (3) Sound power measured according to standards ISO 3741 - max speed available in cooling mode (4) Measured at max speed available in cooling mode All data reported in the table above refer to maximum allowed ventilation speed in order to avoid the drag of the condensation drops generated...
Open the catalog to page 6(1) Water temperature 85°C / 75°C, air temperature 15°C - 100% of the max speed (2) Sound power measured according to standards ISO 3741 - 100% of the max speed
Open the catalog to page 7Fan heaters - AREO LEGEND 1 Water inlet connection female gas 2 Water outlet connection female gas
Open the catalog to page 8LEGEND 1 Water inlet connection male gas 2 Water outlet connection male gas
Open the catalog to page 9Fan heaters - AREO LEGEND 1 Water inlet connection male gas 2 Water outlet connection male gas
Open the catalog to page 10All Galletti catalogs and technical brochures
-
EFFETTO
4 Pages
-
PLE
6 Pages
-
LCX
16 Pages
-
VLS
19 Pages
-
PLI
6 Pages
-
MPIDC
6 Pages
-
UTN 3 - 23 kW
6 Pages
-
FLAT S 1 - 3 kW
4 Pages
-
Fan Coil ART-U
10 Pages
-
WRE
12 Pages
-
Fan coil FM
4 Pages
-
VLE
10 Pages
-
ACQVARIA
6 Pages
-
FLAT Li
4 Pages
-
FLAT L
4 Pages
-
ESTRO
14 Pages
-
DUCTIMAXi
6 Pages
-
DUCTIMAX
6 Pages
-
DST
2 Pages
-
ART-U 1
6 Pages
-
AREO i
4 Pages
-
AREO
6 Pages
-
V-IPER 50 - 380 kW
12 Pages
-
Air chillers and heat pumps MPE
12 Pages
-
Air destratifiers DST
2 Pages
-
Static convector KAIMAN
2 Pages
-
galetti company profile
15 Pages
-
EVO
2 Pages
-
RYT
4 Pages
-
IWC
6 Pages
-
IWCi
4 Pages
-
ESTRO i
12 Pages