Catalog excerpts
Air chillers and heat pumps MPE Outdoor monobloc unit MPE 4 - 76 kW Efficiency under all operating conditions Rotary compressor Scroll compressor Cooling only Cooling / Heating Monobloc unit Axial fans PLUS Completely configurable range Dual-compressor version that guarantees high efficiency at partial loads Production of chilled water up to an air temperature of 51 °C Built-in hydronic unit Access to the tax incentives provided for energy retrofitting MPE water chillers and heat pumps are designed for outdoor installation in both residential and industrial applications. The range uses R410A refrigerant, which assures high levels of performance with relatively low energy consumption and features 25 models in the chiller and heat pump version, with cooling capacities ranging from 4 to 76 kW and heating capacities from 5 to 85 kW. The finned block heat exchangers have been optimised for R410A and use 8 mm copper pipes, which permit a better heat exchange and quiet operation of the fans. Their generous sizing guarantees the production of chilled water even with outdoor air temperatures as high as 51°C. In the MPET models, with a double compressor on the same cooling circuit, the working temperature range is extended further and efficiency at partial loads increases. In demanding working conditions the microprocessor controller activates the capacity control mode, doubling the condensing surface available to the single compressor. The self-adaptive logic allows the setpoint to be adjusted automatically according to the outdoor temperature in order to reduce consumption and broaden the working temperature range. The unit can also function in systems with a low water content, even without the use of a water buffer tank, thanks to the automatic adjustment which limits the number of compressor starts and thus extends the life of the compressors themselves. The exclusive Smart Defrost System (optional feature available with the advanced controller) can correctly identify an impairment of performance in the outdoor exchanger due to the formation of ice and minimise the process time in relation to normal operation of the unit. MPE heat pumps and water chillers are designed for heating or cooling the water to be used in air-conditioning systems for residential or commercial use.
Open the catalog to page 1MAIN COMPONENTS Structure Painted galvanised sheet steel structure (RAL9002) for an attractive look and effective resistance to corrosive agents. Fastening devices are made of non-oxidizable carbon steel that has undergone surface-passivating treatments. Customised hydraulic kit The structure can accommodate hydronic kits with pump, expansion tank, and buffer tank. High head pump made entirely of stainless steel, already configured for use with mixtures of water and ethylene glycol up to 35% and provided with internal thermal protection. Fan drive assembly Electric fan with external rotor...
Open the catalog to page 2Air chillers and heat pumps MPE Rated technical data MPE-C (1) Water temperature 12/7 °C, outdoor air temperature 35 °C (UNI EN 14511:2011) (2) Sound power level measured according to UNI EN ISO 9614 (E) EUROVENT certified data
Open the catalog to page 3Rated technical data Air chillers and heat pumps - MPE (1) Water temperature 12/7 °C, outdoor air temperature 35 °C (UNI EN 14511:2011) (2) Sound power level measured according to UNI EN ISO 9614 (E) EUROVENT certified data
Open the catalog to page 4Air chillers and heat pumps MPE Rated technical data MPE-H (1) Water temperature 12/7 °C, outdoor air temperature 35 °C (UNI EN 14511:2011) (3) Sound power level measured according to UNI EN ISO 9614 (2) Water temperature 40/45 °C, outdoor air temperature 7 °C D.B. / 6 °C W.B. (UNI EN 14511:2011) (E) EUROVENT certified data
Open the catalog to page 5Rated technical data (1) Water temperature 12/7 °C, outdoor air temperature 35 °C (UNI EN 14511:2011) (3) Sound power level measured according to UNI EN ISO 9614 (2) Water temperature 40/45 °C, outdoor air temperature 7 °C D.B. / 6 °C W.B. (UNI EN 14511:2011) (E) EUROVENT certified data Air chillers and heat pumps - MPE VM66000387-C
Open the catalog to page 6Air chillers and heat pumps MPE Dimensional drawings li taco a os area ro d libe clear coli osta o da ar area r libe cle Water outlet 1" female Safety valve discharge outlet provided with rubber ring holder Water supply ½" male (optional tap) Water drainage ½" female Electric control board Water inlet 1" female Fastening points for vibration dampers (accessory)
Open the catalog to page 7Dimensional drawings 1 ENTRATA ACQUA 1" FEMMINA 2 USCITA ACQUA 1" FEMMINA 3 SCARICO VALVOLA DI SICUREZZA CON PORTAGOMMA 4 ALIMENTAZIONE ACQUA 1/2" MASCHIO (RUBINETTO OPTIONAL) EMMINA 5 SCARICO ACQUA 1/2" FEMMINA MMINA 6 ALIMENTAZIONE ELETTRICA Ø28 SICUREZZA CON PORTAGOMMA 7 QUADRO ELETTRICO UA 1/2" MASCHIO (RUBINETTO OPTIONAL) 8 ANTIVIBRANTI oli stac da o r area ro libe clea oli stac da o r area ro libe clea Air chillers and heat pumps - MPE Water inlet 1" female Water outlet 1" female Safety valve discharge outlet provided with rubber ring holder Water supply ½" male (optional tap) Water...
Open the catalog to page 8Air chillers and heat pumps MPE Dimensional drawings 1 ENTRATA ACQUA 1 1/4" FEMMINA 2 USCITA ACQUA 1 1/4" FEMMINA 3 SCARICO VALVOLA DI SICUREZZA CON PORTAGOMMA 4 ALIMENTAZIONE ACQUA 1/2" MASCHIO (RUBINETTO OPTIONAL) 1 ENTRATA ACQUA 1 1/4" FEMMINA 5 SCARICO ACQUA 1/2" FEMMINA 2 USCITA ACQUA 1 1/4" FEMMINA 6 ALIMENTAZIONE ELETTRICA Ø28 3 SCARICO VALVOLA DI SICUREZZA CON PORTAGOMMA 7 QUADRO ELETTRICO 4 ALIMENTAZIONE ACQUA 1/2" MASCHIO (RUBINETTO OPTIONAL) 8 ANTIVIBRANTI 5 SCARICO ACQUA 1/2" FEMMINA 6 ALIMENTAZIONE ELETTRICA Ø28 7 QUADRO ELETTRICO 8 ANTIVIBRANTI li taco a os area ro d libe...
Open the catalog to page 9Dimensional drawings A CON PORTAGOMMA ASCHIO (RUBINETTO OPTIONAL) 1 ENTRATA ACQUA 1 1/4" FEMMINA 2 USCITA ACQUA 1 1/4" FEMMINA 3 SCARICO VALVOLA DI SICUREZZA CON PORTAGOMMA 4 ALIMENTAZIONE ACQUA 1/2" MASCHIO (RUBINETTO OPTIONAL) 5 SCARICO ACQUA 1/2" FEMMINA 6 ALIMENTAZIONE ELETTRICA Ø37 7 QUADRO ELETTRICO 8 ANTIVIBRANTI Air chillers and heat pumps - MPE Water inlet 1" ¼ female Water outlet 1" ¼ female Safety valve discharge outlet provided with rubber ring holder Water supply ½" male (optional tap) Water drainage ½" female Electric control board Vibration dampers
Open the catalog to page 10All Galletti catalogs and technical brochures
-
EFFETTO
4 Pages
-
PLE
6 Pages
-
LCX
16 Pages
-
VLS
19 Pages
-
PLI
6 Pages
-
MPIDC
6 Pages
-
UTN 3 - 23 kW
6 Pages
-
FLAT S 1 - 3 kW
4 Pages
-
Fan Coil ART-U
10 Pages
-
WRE
12 Pages
-
Fan coil FM
4 Pages
-
VLE
10 Pages
-
ACQVARIA
6 Pages
-
FLAT Li
4 Pages
-
FLAT L
4 Pages
-
ESTRO
14 Pages
-
DUCTIMAXi
6 Pages
-
DUCTIMAX
6 Pages
-
DST
2 Pages
-
ART-U 1
6 Pages
-
AREO i
4 Pages
-
AREO 8
10 Pages
-
AREO
6 Pages
-
V-IPER 50 - 380 kW
12 Pages
-
Air destratifiers DST
2 Pages
-
Static convector KAIMAN
2 Pages
-
galetti company profile
15 Pages
-
EVO
2 Pages
-
RYT
4 Pages
-
IWC
6 Pages
-
IWCi
4 Pages
-
ESTRO i
12 Pages