AL 400
4Pages

{{requestButtons}}

Catalog excerpts

AL 400 - 1

AL400120 Table ventilation Stainless steel Width 120 cm Air extraction/recirculation with remote fan unit AR 400/401/403/413 Motorless Telescopic table ventilation for combination with all Gaggenau cooktops, completely retractable when not in use Dimmable LED light for illumination of the whole cooktop Precision crafting of 3 mm stainless steel For surface installation with a visible edge or for flush installation Can be combined perfectly with other Vario appliances of the 400 series Color Variants AL400120 Stainless steel Width 120 cm Installation Accessories AA010410 Air exhaust grille recirculation mode AA409430 Furniture support 116 cm for AT 400 131 ZB020090 Ventilation grille stainless steel Product Variants AL400190 Table ventilation Stainless steel Width 90 cm Air extraction/recirculation with remote fan unit AR 400/401/403/413 Motorless Output Maximum air output in combination with remote fan units s. table remote fan units on page xxx. Sound power level depends on the built-in situation. Features 3 electronically controlled output levels. Intensive mode. Interval ventilation. Run-on function. Grease filter saturation indicator. Cartridge-type filter, dishwasher-safe. LED light. Spare covers for closing air outlets. No duct connection piece included. Planning notes For operation with 4 Vario 200 series cooktops, 3 Vario 400 Series cooktops or a cooktop configuration of up to 120 cm wide. Max. output of induction and glass ceramic cooktops 12 kW. In combination with the cooktop CI 490, installation in 60 cm deep worktops is possible. Operation of Vario cooking appliances only possible without appliance cover. Installation is possible in worktops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the cut edges must be observed. Concerning other materials please consult the worktop manufacturer. If the remote fan unit is installed within the bottom cabinet and if combined with VK or VF ensure accessibility to the outlets. The remaining surface of the worktop (min. 50 mm) between the cut-outs must be reinforced with a support. It is recommended to use furniture support AA 409 400/430. Ovens that do not exceed the maximum allowed cabinet temperature can be combined with the table ventilation if built-in situation permits. Recommendation for stainless steel parts to match hood that have to be welded and polished: brushed grain 280. Surfaces: Stainless steel 1.4301, ground and brushed IIIC. For air recirculation: The exhaust outlet in the plinth should be as large as possible to minimise draughts. The location of the exhaust outlet in the plinth is consumer-defined. Minimum cross-section 720 cm2. To avoid smoke when frying/grilling refer to the manuals of VR/VP. For air extraction: Characteristics Product name/family Color chimney Typology Traditional Approval certificates CE, VDE Length of electrical supply cord (cm) 170 Required niche size for installation (HxWxD) 540mm x 1140mm x 122mm Height of the chimney (mm) Height of product, without chimney (mm) 540 Minimum distance above an electric hob Minimum distance above a gas hob Net weight (kg) 40.0 Type of control Electronic Number of speed settings 3 Maximum output air extraction (m3/h) 0 Boost position output recirculating (m3/h) Maximum output recirculating air (m3/ h) Boost position air extraction (m3/h) Number of lights (Stck) 4 Noise level (dB(A) re 1 pW) Diameter of air outlet (mm) Grease filter material Washable synthetic Consumption and connection features Connection Rating (W) Current (A) 10 Voltage (V) 230 Frequency (Hz) 50 Plug type CH plug w/ earthing, Gardy plug w/ earthing, GB plug, special connection Installation type Half-integrated created on 2015-03-10 Page 1 For maximum duct lengths use Gaggenau flat rectangular ducts AD 8… or Naber-System Compair flow. Other flat ducts are not permitted! Duct connection front or backwards: 2 ducts DN 150 cylindrical or flat rectangular duct. Downwards 2 ducts DN 150 flat rectangular duct (installation accessory). When installing a ventilation hood with air extraction mode and a chimneyvented fireplace, the hood's power supply line needs a suitable safety switch. Connection Connecting cable 1.7 m with plug.

Open the catalog to page 1
AL 400 - 2

Table ventilation Stainless steel Air extraction/recirculation with remote Depth measurements - base unit without back panel - recirculation for maximum power with 2x NW 150 Circulated air: AL 400 with AR 413 in the base unit Depth measurements - base unit without back panel - exhaust air mode for maximum power with 2x NW 150 Exhaust air: AL 400 with AR 400 in the base unit pipe on left or right

Open the catalog to page 2
AL 400 - 3

AL400120 Table ventilation Stainless steel Width 120 cm Air extraction/recirculation with remote fan unit AR 400/401/403/413 Motorless created on 2015-03-10 Page 3

Open the catalog to page 3
AL 400 - 4

Table ventilation Stainless steel Air extraction/recirculation with remote Longitudinal section fill with silicone

Open the catalog to page 4

All GAGGENAU catalogs and technical brochures

  1. CX482101

    2 Pages

  2. AW442120

    2 Pages

  3. CE291101

    1 Pages

  4. VG491111F

    3 Pages

  5. AI442100

    2 Pages

  6. The EB 333

    4 Pages

  7. The range 2023

    184 Pages

  8. EB333111

    2 Pages

  9. AL400121

    3 Pages

  10. BMP224100

    2 Pages

  11. BMP224110

    2 Pages

  12. CM450101

    1 Pages

  13. CM450111

    1 Pages

  14. CMP250111

    1 Pages

  15. The range 2019

    114 Pages

  16. RC492304

    2 Pages

  17. RB472304

    2 Pages

  18. WT260101

    2 Pages

  19. WM260163

    2 Pages

  20. WS462100

    2 Pages

  21. CMP250101

    2 Pages

  22. WM 260

    2 Pages

  23. VI 491

    2 Pages

  24. Edition 2013

    364 Pages

Archived catalogs

  1. CM450111

    2 Pages

  2. CM450101

    2 Pages