Technique Exterior
Open the catalog to page 1In this brochure we will give you all the technical information around the Max Exterior panel, which is made for outdoor applications. Max Exterior is not only a facade panel for the rear ventilated facade. The properties of the panel qualify it for all other outdoor-applications - like balconies or railing-fillers, outdoor-furniture, sunblinds, porches etc. also. But there are many other ideas to use Max Exterior. If you have any questions, which are not answered in this brochure, please get in contact with our sales represantatives or the technical support department. We are pleased to help...
Open the catalog to page 2General Information Sandwich Elements Balcony Floor Panels Roof Claddings Window shutters More Application Possibilities for Max Exterior The diagrams in this technical information are schematical representations. FUNDERMAX exterior Technique
Open the catalog to page 3Max Exterior panels are duromer high-pressure laminates (HPL) in accordance with EN 438-6 Type EDF that are produced in lamination presses under great pressure and high temperature. Double-hardened acrylic PUR resins provide extremely effective weather protection that is particularly suitable for longlasting balconies and façade claddings. Scratch resistant_________ _________Extremely weather resistant _________Optimal light-fastness _________Impact resistant Solvent resistant_________ Properties*: __Weather resistant to EN ISO 4892-2 __lightfast acc. to EN ISO 4892-3 __Double hardened __Scratch...
Open the catalog to page 4Max Exterior F-Quality As a standard, Max Exterior panels come printed on both sides. The core is flame-retardant and the surface is lightfast. Thanks to the double-hardened resin, it is also extremely weather resistant. (Fire Test EN 13501-1, B-s2,d0) Max Exterior Alu-Compact 42 F-Quality The design meets F-Quality standards and is additionally provided on both sides with aluminium bands under the print layer. This ensures that even perforated panels are extremely stable. (Fire Test EN 13501-1, B-s2,d0) Sandwich-Elements The Max Exterior panels in F-Quality also come polished on just one side...
Open the catalog to page 5General information Max Exterior F-Quality Acrylic PUR-resin (weather protection) Max Exterior is a high-quality construction product which is used especially for long-lasting balcony and facade claddings. Max Exterior panels are duromer high-pressure laminates (HPL) in accordance with EN 438-6 Type EDF with extremely effective weather protection. This weather protection consists of double-hardened acrylic polyurethane resins. They are produced in lamination presses under great pressure and at high temperatures. Max Exterior panels are, of course, labeled with the CE-Mark necessary for their...
Open the catalog to page 6Physical data Test method Standard value Actual value Artificial weathering UV-light resistance Test method Standard value Actual value Apparent density Flexural strength Tensile strength Coefficient of thermal expansion Thermal conductivity Water vapour diffusion resistance Light-fastness and weather resistance (surface NT) Fire behaviour Europe EMPA Dübendorf Facade permit Germany ETB guidelines for building components which safeguard against falls, June 1985. Balcony railings. Passed (depending on building regulation and railing construction 6, 8 or 10 mm panel thickness) Avis technique France...
Open the catalog to page 7General information Max Exterior Alucompact42 F-Quality Acrylic PUR-resin (weather protection) Max Exterior Alucompact panels are duromer highpressure laminates (HPL) according to EN 438, with extremely effective weather protection. This weather protection consists of double-hardened acrylic polyurethane resins. They have 0,42 mm thick aluminium layers on both sides under the decor layers. Plain-decor or printed-decor Aluminium band These aluminium layers provide an extremely high breaking strength and stiffen the panels to an extraordinary degree. This makes it possible, on the one hand, to...
Open the catalog to page 8Physical data Alucompact Properties Test method Standard value Actual value Lichtechtheit und Witterungsbeständigkeit (Oberfläche NT) Artificial weathering UV-light resistance Test method Standard value Actual value Apparent density Flexural strength Impact resistance (Dynstat) Water vapour diffusion resistance Fire behavior Europe Passed (depending on building regulation and railing construction 6 mm panel thickness) Permits ETB-guidelines for building components which safeguard against falls, June 1985. Balcony railings. All the respective current certificates and approvals are available in...
Open the catalog to page 9FUNDERMAX exterior Technique
Open the catalog to page 10Content Façades Qualifications Function and advantages of back ventilated façades Material characteristics Visible screwed fastening Visible revited fastening Secret mechanical fastening (with undercut anchor) Secret glued fastening System ME 01 System ME 02 System ME 03 (lap siding) Design possibilities Qualifications A Max Exterior panels in thicknesses of 6–10 mm are EUROCLASS B–s2, d0 in accordance with EN 13501–1. CH Fire Classifications 5 (200°C). 3 for 6–13 mm Max Exterior Type CGF–VKF Permit. No. 9683 Max Exterior panels in thicknesses of 6–10 mm are B1 in accordance with DIN 4102 and...
Open the catalog to page 11Function and advantages of a nonbearing, rear-ventilated facade Insulation The non-bearing, rear-ventilated facade (VHF) system can be designed for different energy requirements with an individually calculated insulation. Insulation material of any desired thickness can be used. This means insulation values can easily be achieved that are typical of low-energy houses and comply with the current energy savings regulations. Based on the energy needs, the insulation maximizes the heat retention of the building. High summer temperatures in the interior of the building are regulated. By reducing the...
Open the catalog to page 12Diffusion permeable Heat insulating Material Characteristics Max Exterior shrinks when it loses moisture! Max Exterior expands when it absorbs moisture! When working and constructing with the panels, thought must be given to this possible dimensional change. For Max Exterior it is basically half as much lengthways as widthways (see properties on page 7 and 9; lengthways is relative to the nominal panel format!) Element length = a Element width = b a or b (in mm) 500 FUNDERMAX exterior Technique
Open the catalog to page 1312 Pages
1 Page
4 Pages
20 Pages
12 Pages
48 Pages
48 Pages
1 Page
4 Pages
48 Pages
12 Pages
32 Pages
28 Pages
2 Pages
24 Pages
8 Pages
34 Pages
87 Pages
4 Pages
8 Pages
8 Pages
8 Pages
2 Pages
68 Pages
4 Pages
28 Pages
84 Pages
28 Pages
4 Pages
80 Pages
64 Pages
42 Pages
28 Pages
92 Pages
100 Pages
28 Pages
96 Pages
36 Pages
80 Pages