Catalog excerpts
PA2200C Stylish air curtain for entrances, with remote and integrated control • Recommended installation height 2,2 m* The PA2200C is a compact air curtain, suitable for most small entrances. The air curtain has an integrated control system and can also be remotely controlled which makes it very easy to use. PA2200C creates a temperature dividing air barrier that effectively prevents cold draughts and gives excellent heating comfort inside the door. • Horizontal mounting • Lengths: 1, 1,5 and 2 m 1 Ambient, no heat 3 Electrical heat: 3–16 kW 2 Water heat Design With its timeless design PA2200C is suitable for all entrances. The air curtain has a control panel discretely integrated in the end, which makes cable routing unnecessary. The front can be nished in any colour to perfectly match the environment. Optimized airow with Thermozone technology. Product specications • Remote control and integrated regulation. • 3 fan steps and 2 electrical heating steps. • Units with 3 kW are equipped with 1,5 m cable and plug. • Wall brackets included. • The front is easy to remove, which facilitates installation and allows easy maintenance. • Corrosion proof housing made of hot zinc-plate and powder enamelled steel panels. Colour front: white, RAL 9016, NCS S 0500-N. Colour grille, rear section, ends and brackets: grey, RAL 7046. *) Recommended installation height varies depending on the relevant premises. Measurements according to ISO 27327-1. Average values for products in the series.
Open the catalog to page 1Technical specifications Type Output Airflow*1 Sound Voltage Amperage Length Weight Length Weight Type Output*4 Airflow*1 At*3-4 Water Sound Voltage Amperage Length Weight volume level*2 motor motor *1) Lowest/highest airflow of totally 3 fan steps. *2) Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent absorption area: 200 m2. At lowest/highest airflow. *3) At = temperature rise of passing air at maximum heat output and lowest/highest airflow. *4) Applicable at water temperature 80/60 °C, air temperature, in +18 °C. Protection class for units with electrical...
Open the catalog to page 22 metre units Cu ø15 53 Unit without heating or with water heating 157 71 40 Unit with electrical heating 157
Open the catalog to page 3PA2200C Mounting and connection Mounting The air curtain is installed horizontally with the supply air grille facing downwards as close to the door as possible. Different installation options are available; brackets for wall mounting (included in delivery) and hanging brackets or threaded bars for ceiling mounting. Minimum distance from outlet to floor for electrically heated units is 1800 mm. Connection Unit without heating Connected via the built-in control board with 1,5 m cord and plug. The front is easy to remove, which facilitates installation and allows easy maintenance. Unit with...
Open the catalog to page 4PA2PF ceiling mounting brackets , Mountings for installing the unit in the ceiling using hanging brackets or threaded bars (not included). PA34TR, threaded bars Threaded bars for installing unit on to a ceiling. Length 1 m. Used together with ceiling mounting brackets PA2PF. PAMLK, motor alarm board Used for units that do not have withdrawn thermal contact. For units with SIRe, connect the board to the SIRe automatic for motor alarm indication. For other units the potential free alarm switch for external alarm is used. PA2P hanging brackets , Hanging brackets for installing the unit...
Open the catalog to page 5PA2200C Control options The control system is integrated in the air curtain. The air curtain has a control panel discretely integrated in the gable end and can be controlled by a separate remote control. The air speed is set manually. The heat is controlled automatically. Door switch control PA2DR is available as an accessory for a door switch function. Possibility of using external on/off. ~ 20 °C Fan step 1/2/3 Heating on/off (W) Half/full power (E) On/off VOT, three way control valve and actuator on/off Used to control the water supply to water heated units. DN15/20/25. VOS, valve kit...
Open the catalog to page 6Output charts water *1) Recommended outlet air temperature for good comfort and optimized output. *2) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
Open the catalog to page 7PA2200C Wiring diagrams Internal wiring diagram Unit without heating 0 - 10V HEAT ALARM WATER Blue Brown Black Blue Brown Black INTERNAL SENSOR Left motor Right motor Unit with electrical heating 400V 3N~ Over heat cut-out Blue Brown Black C° INTERNAL SENSOR 0 - 10V HEAT ALARM WATER
Open the catalog to page 8PA2200C Wiring diagrams Internal wiring diagram 400V 3N~ Unit with electrical heating Over heat cut-out Over heat cut-out 0 - 10V HEAT ALARM WATER Blue Brown Black Blue Brown Black INTERNAL SENSOR Left motor Right motor Over heat cut-out Over heat cut-out Blue Brown Black Blue Brown Black M ~ Left motor INTERNAL SENSOR 0 - 10V HEAT ALARM WATER
Open the catalog to page 9PA2200C Wiring diagrams Internal wiring diagram Unit with water heating 0 - 10V HEAT ALARM WATER Blue Brown Black Blue Brown Black Left motor Right motor PAMLK, motor alarm board Motor alarm (pot. free contact) Run Blue Brown Black Blue Brown Black INTERNAL SENSOR 0 - 10V HEAT ALARM WATER
Open the catalog to page 10All FRICO catalogs and technical brochures
-
PAEC 2500
5 Pages
-
PAECS
4 Pages
-
AGI6000
7 Pages
-
Pamir 5000
10 Pages
-
PA2200C
6 Pages
-
Ruwen
7 Pages
-
Scand
6 Pages
-
Sierra
10 Pages
-
Arden 4200
8 Pages
-
Arden 3500
8 Pages
-
Pamir 3500
10 Pages
-
Pamir 2500
8 Pages
-
Infralu
3 Pages
-
PAEC2500/3200
4 Pages
-
AR3500/4200
5 Pages
-
AGS5500/AGR5500
4 Pages
-
UF600
4 Pages
-
AR200 A/E/W
2 Pages
-
PA2500 A/E/W
3 Pages
-
Fläktkonvektor PF
2 Pages
-
Mini radiator FML
2 Pages
-
Thermowarm TWT
2 Pages
-
Bench heater SH
1 Pages
-
Ribbed pipe radiator
2 Pages
-
LAF10 Dehumidifier
4 Pages
-
Thermostats
4 Pages
-
PF
2 Pages
-
K21
2 Pages
-
Elztrip EZF42
2 Pages
-
AC500
2 Pages
-
Portier E/A
8 Pages
-
AD200 A/E
14 Pages
-
ADA
2 Pages
-
AD100 E
4 Pages
Archived catalogs
-
Fan Heaters
8 Pages
-
Radiant Heaters
8 Pages
-
Air Curtains
8 Pages