double-skin supply unit regulated heating coil Novatys® regulated double-skin supply unit with integrated and regulated + autoregulated heating coil • Product entierly wired : ready to use (Novatys® regulated). • Optimum control of heating level by electronic heating level (Novatys® regulated). • Low sound level and reinforced thermal insulation 30 mm. • Careful finish : double-skin casing. • Regulated heating coil included. • Range composed of 6 sizes. • Circular connection Novatys 7/7 to 12/12. • Rectangular connection Novatys from model 15/15 to 18/18. • Motorization 1 speed and 2 speeds. • Novatys version with autoregulated hot water coil with filter • Regulation by motorized 3 way valves. • Novatys version with autoregulated hot water coil with filter draw, power from 4,5 Kw to 72 kW. • Regulation by a multi-step thermostat integrated to unit. • Filtration module G4-F7 (option). • Fresh air supply in tertiary premises. - Supply intake in line. - One piece unit with electric or hot water coil. - Structure in aluminium profile, angles in reinforced polypropylene. - Insulation in expanded polystyrene. - Detachable panels, painted grey RAL 7001 - Unit fitted with M8 crimped in aluminium profile structure. - Only floor installation. Coil not interchangeable on worksite. Connection of high filtration module by fastenings. Forward centrifugal, double inlet, assembled on silent bloc and connected to the supply panel. - Motor Type B3 with aluminium feet service SI. - 1 speed : 4 poles three-phase 230 V / 400 V - 50 Hz - IP 54 - Class F-PTO. - 2 speeds : 4/8 poles Dahlander Three 400 V - 50 Hz - IP 54 - Class F-PTO. - Transmission pulley-belt, driving pulley variable when stopped. - Transmission assembled to the left, standard. ' Novatys® regulated - The Novatys is delivered with an integrated and regulated heating battery. - Power contactor, 1 or 2 speeds. • Regulation electric version : - Regulation by a multi-step thermostat integrated to the unit. regulator with 3+ J steps with sensor to position in Alimentation Three+Neutral - Regulation by 3 way valves, motorized. ® Motorized three way valves Alimentation Three+Neutral • By unit on palette with protection film. • The supply unit with integrated and auto-regulated heating coil (electric version or hot water version), will have a profile structure in aluminium with insulated double skin panels 30 mm of expanded polystyrene, a centrifugal double inlet forward fan and a motor with feet with a pulley-belt • Type Novatys, France Air brand. Guide created by France Air 2010. All rights reserved
Open the catalog to page 1technical description > Dimensions, reservation and weight • Electric version Only autoregulated version Guide created by France Air 2010 - All rights reserved.
Open the catalog to page 2selection graphs Rotation speed range of the transmission : In green : sound pressure level at 4 m. The selection graphs of Novatys integrate Rotation speed range of the transmission : In green : sound pressure level at 4 m. Rotation speed range of the transmission : In green : sound pressure level at 4 m. Guide created by France Air 2010. All rights reserved.
Open the catalog to page 3selection graphs Rotation speed range of the transmission : In green : sounf pressure level at 4 m. The selection graphs of Novatys integrate Rotation speed range transmission : In green : sound pressure level at 4 m. Rotation speed range of the transmission : In green : sound pressure level at 4 m. Guide created by France Air 2010 - All rights reserved.
Open the catalog to page 4selection charts pressure drop on water kPa • Correction coefficients PDC water KPa • Correction coefficients for calorific power • Opposite chart: correction coefficients to apply to power shown in the chart according to the different air inlet temperatures and the water supply (air 15 °C - water 90/70 °C). Guide created by France Air 2010. All rights reserved.
Open the catalog to page 5consumption graphs of fans Guide created by France Air 2010 - All rights reserved. WWW.f raflCe-air.COm
Open the catalog to page 6consumption graphs of fans Guide created by France Air 2010. All rights reserved.
Open the catalog to page 7• Circular flange from 7/7 to 12/12. > Circular flexible sleeve • For suction panel from 7/7 to 12/12. • Assembly on to suction panels or directly • Rectangular flange from 15/15 to 18/18. • For a connection of the duct on to the Novatys (without sleeve). > Circular flexible sleeve • Screw onto a rear panel of Novatys (can not be fixed to the suction panel). > Filtration casing G4+F7 compact > Filtration casing G4+F7 pocket • Free suction/extraction. > 1 ways mixing casing > 3 ways mixing casing > Switch - electric versions on/off coil - Speed selection IV- general on/off + on/off coil > Switch...