FAN HEATERS LEO

Product catalog summary
General Characteristics
LEO fan heaters are designed for indoor use in both large industrial spaces and smaller areas like workshops. They feature a 3-speed fan for easy operation and can be integrated with Building Management Systems (BMS) using various controllers. The casing is made from expanded polypropylene (EPP), known for its durability and resistance to dirt.
Construction
Available in different casing options such as standard EPP, stainless steel (INOX), or powder-painted metal (RAL), LEO fan heaters can be equipped with a mixing chamber to function as a heating and ventilation unit.
Technical Data
LEO fan heaters come in models S, L, and XL, offering heating capacities from 0.7 kW to 121 kW and airflows from 1000 m³/h to 5800 m³/h. They operate on a 230V/50Hz power supply with a maximum operating pressure of 1.6 MPa.
Installation and Mounting
These heaters can be mounted on walls or ceilings with adjustable angles. Recommended installation distances vary by model to ensure optimal air distribution. Accessories like confusors and outlet grilles enhance air distribution, especially in rooms with low ceilings.
Control Systems
LEO heaters offer manual or automatic control options, including local regulation and BMS integration. The T-box touch screen controller can manage up to 31 units, providing intelligent solutions and energy savings.
Accessories
Accessories such as confusors and 4-side outlet grilles are available to optimize air distribution and performance in various installation scenarios.
Specifications
The document details specifications for LEO fan heaters with KM mixing chambers, including dimensions, air flow, heat power, power supply, and more. It also covers acoustic levels, heating water temperature, operating pressure, and connection size.
Installation Recommendations
Installation guidelines include recommended distances and methods using brackets or pins, with specified maximum and minimum heights for different models.
Control Systems
Various control systems are described, including TS, HMI, and T-box controllers, offering features like fan speed regulation, operating modes, antifreeze protection, and BMS integration.
Connection Diagrams
Diagrams for connecting LEO fan heaters to control systems and BMS are provided, outlining wiring requirements and the maximum number of units per controller.
Heating Capacities
Tables for calculating heating capacities based on parameters like air flow, temperatures, water flow rate, and pressure drop are included, along with a heat output calculator.
Control Elements
Technical data for control elements such as thermostats and valves are provided, detailing protection degree, power supply, and temperature ranges.
Integration with FLOWAIR SYSTEM
The FLOWAIR SYSTEM allows integration of various devices with a single T-box controller for efficient management of heating and ventilation systems.
Overview
The document provides detailed technical specifications and testing results for LEO fan heaters, focusing on heating capacities and air flow rates.
Quality Label
A quality label is introduced to standardize technical parameters, ensuring reliable and comparable data for consumers.
Testing Procedures
Testing procedures for efficiency, heating power, and acoustic pressure levels are outlined, conducted in accredited labs to ensure compliance with international standards.
Recommendations
The document emphasizes the importance of standardizing technical parameters across the industry for easier product comparison and selection by consumers.
See more

Catalog excerpts

FAN HEATERS LEO-3

Heating capacity [kW] Air flow [m3/h] Weight [kg] Casing Colour (1) EPP is an expanded polypropylene, which is good thermal insulator, is resistant to dirt and has high ability of vibration damping. This features allowed to use it as a material for casing of the unit and lowered its total weight. (2) similar to RAL 9007 I APPLICATION LEO fan heaters are designed to operate indoors. They are used to heating rooms with a big cubic measure like industrial buildings, warehouses, departments stores, production halls, sports halls (gyms), sacral buildings etc. They can also be used in smaller rooms...

 Open the catalog to page 3
FAN HEATERS LEO-4

CONSTRUCTION BMS Connection of devices to the BMS system (Building Management System) is possible via a T-box or HMI controller or via the DRV control module. 3-SPEED FAN LEO fan heaters are equipped with 3 speed fans. It’s the simplest and most effective way to control the fan heater’s operation. EPP CASING Mechanical strength, resistance to dirt, low weight and aesthetic look. By applying expanded polypropylene for casing construction, LEO fan heaters create a new quality in heating and ventilation. MIXING CHAMBER LEO fan heaters with LEO KM mixing chamber form heating and ventilation unit....

 Open the catalog to page 4
FAN HEATERS LEO-5

COMPARE LEO SOLUTIONS When you need a simple solution! linia Basic Intelligent solutions compatible with FLOWAIR SYSTEM • the cheapest offer on the market (as a kit) • easy connection • 3-speed manual efficiency control • intelligent solutions and energy savings • control up to 31 devices compatible with the FLOWAIR SYSTEM • BMS control • local regulation • 3-speed automatic efficiency control • easy connection SET Fan heater LEO • 3 speed fan • light and durable EPP casing • wide range of heating power 0,7-121 kW Fan heater LEO • 3 speed fan • light and durable EPP casing • wide range of heating...

 Open the catalog to page 5
FAN HEATERS LEO-6

| For CAD drawings, Revit files and documentation for all available versions of LEO visit www.flowair.com Step Max. air flow stream [m3/h] Heating capacity [kW](1) Nominal heat power (70/50/16°C, MI-step) [kW] Power supply [V/Hz] Max. current consumption [A] Max. power consumption [W] IP/Insulation class Max. acoustic pressure level [dB(A)](2) Max. acoustic power level [dB(A)](3) Horizontal range [m](4) Vertical range [m](5) Max. heating water temperature [oC] Max. operating pressure [MPa] Connection Max. operating temperature [oC] Weight of unit [kg] Weight of unit filled with water [kg] 1,1...

 Open the catalog to page 6
FAN HEATERS LEO-7

Fan heater LEO L Step Max. air flow stream [m3/h] Heating capacity [kW](1) Nominal heat power (70/50/16°C, MI-step) [kW] Power supply [V/Hz] Max. current consumption [A] Max. power consumption [W] IP/Insulation class Max. acoustic pressure level [dB(A)](2) Max. acoustic power level [dB(A)](3) Horizontal range [m](4) Vertical range [m](5) Max. heating water temperature [oC] Max. operating pressure [MPa] Connection Max. operating temperature [oC] Weight of unit [kg] Weight of unit filled with water [kg] Fan heater LEO XL Step Max. air flow stream [m3/h] Heating capacity [kW](1) Nominal heat power...

 Open the catalog to page 7
FAN HEATERS LEO-8

RANGES HORIZONTAL RANGE OF AIR STREAM – isothermal Horizontal range of isothermal stream at velocity boundary equal to 0,5 m/s. VERTICAL RANGE OF AIR STREAM – non-isothermal Vertical range of non-isothermal stream at velocity boundary equal to 0,5 m/s.

 Open the catalog to page 8
FAN HEATERS LEO-9

the above air flow velocity charts refer to the isothermal stream LEO • Air heating and ventilation

 Open the catalog to page 9
FAN HEATERS LEO-11

INSTALLATION TIPS Steady air circulation should be provided in the entire room. Correctly installed heaters should direct the air to the occupied zone. Heaters installed in the corners should direct the air to the center of the room. Heaters installed on the opposite walls should be overlapped. Air outlet should not be limited. Air inlet should not be limited.

 Open the catalog to page 11
FAN HEATERS LEO-12

ACCESSORIES - CONFUSOR LEO dedicated for LEO L and XL Confusor increases air flow speed. It results in faster air distribution to the lower zones of the room. Material: powder painted metal RAL 9007 Weight: 3,8 kg - confusor LEO L 6,2 kg - confusor LEO XL When device is mounted under the ceiling please note the proper nonisothermal air stream range. ACCESSORIES - 4-SIDE OUTLET GRILLE LEO dedicated for LEO L and XL 4-side outlet grille improves air distribution. It is a perfect solution for low level ceiling rooms, where heaters are installed under the ceiling. Outlet grille decreases nominal...

 Open the catalog to page 12
FAN HEATERS LEO-13

ACCESSORIES - MIXING CHAMBER KM available to all models LEO LEO + KM LEO fan heaters with LEO KM mixing chamber form heating and ventilation unit. It is the easiest way to create the efficient mechanical ventilation without additional systems. For CAD drawings, Revit files and documentation for all available versions of LEO visit www.flowair.com

 Open the catalog to page 13
FAN HEATERS LEO-14

(1) For air blades installed vertically. When mounting under a ceiling, the mounting height should be selected depending on the non-isothermal vertical range. Fan heater with mixing chamber LEO KM Max. air flow stream [m3/h](1) Nominal heat power (70/50/16oC, III step) [kW] Power supply [V/Hz] Max. current consumption [A] Max. power consumption [W] IP/Insulation class Max. acoustic pressure level [dB(A)](2) Max. acoustic power level [dB(A)](3) Horizontal range [m](4) Vertical range [m](5) Max. heating water temperature [°C] Max. operating pressure [MPa] Connection Weight of unit [kg] Weight of...

 Open the catalog to page 14
FAN HEATERS LEO-15

I T-box REGULATION FOR LEO LEO BMS fan heaters are equipped with an external DRV V control module, which together with the T-box controller enables: ■ 3-step automatic or manual fan speed regulation, ■ operating modes: heating, ventilation, ■ fan operation in continuous mode (after reaching set temperature, heating medium is cut off while fan is operating at selected step), or thermostatic mode (after reaching set temperature, heating medium is cut off and fan is turned off), ■ antifreeze - automatic protection against too low temperature in the room, ■ weekly programmer, ■ integration with FLOWAIR...