AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS
36Pages

{{requestButtons}}

Catalog excerpts

AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 1

AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS

Open the catalog to page 1
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 2

BUILDINGS WITH NEED OF HEATING FUNCTION INCREASED AESTHETICS I TECHNICAL DATA Version Height of installation Airflow Acoustic pressure level BMS ELiS DUO ELiSA ELiS B W/E W/E/N W/E/N as standard as standard as standard N - without heating elements W - water heat exchanger E-electric heaters - Speed limit at the floor level - Outlet air velocity I APPLICATION ■ hotels ■ offices ■ shopping centers ■ exhibition centers ■ banks ■ airports 2 ELiS • air curtains arid air curtairi-fari heater units

Open the catalog to page 2
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 3

UNIVERSAL SOLUTIONS INDUSTRIAL BUILDINGS ELiS C ELiS T ELiS G Average acoustic pressure level in the room of average sound absorption, volume of 1500 m3, at a distance of 5 m from the unit The maximum value of the outlet speed of the device ■ shops ■ shopping centers ■ petrol stations ■ shopping centers ■ restaurants ■ train stations ■ industrial halls ■ logistics centers ■ warehouses ELiS • air curtains and air curtain-fan heater units 3

Open the catalog to page 3
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 4

FLOWAIR R&D LAB FLOWAIR - expert and manufacturer of HVAC equipment is a member of the EUROVENT Europe’s Industry Association for Indoor Climate. This organisation brings together the largest companies in the industry, which jointly create new guidelines and recommendations that are eventually presented to the European Commission. The Association is looking for solutions related to energy savings inside buildings and the use of air curtains is one of recommended solutions. The use of air curtains allows for thermal protection of the room. Curtains create an air barrier in the door opening...

Open the catalog to page 4
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 5

The test was carried out in the FLOWAIR R&D lab, in order to measure the effectiveness of the air barrier created by the air curtain relative to the temperature difference. ■ TEST 1 Measurement of air temperature difference between the „cooling” and „heating” chambers upon opening the door - with curtain in Off mode. Chamber 1 simulates external conditions (air temperature is 2°C), and chamber 2 simulates conditions inside the building (air temperature is 20°C). ■ TEST 2 The second measurement is the air curtain effectiveness test - the air temperature difference between the „cooling” and...

Open the catalog to page 5
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 6

Casing Steel, aluminium (1) According to ISO 27327-1 (2) For C-W at inlet/outlet water temperature 90/70oC, inlet air temperature 10oC (3) RAL 9016 I AVAILABLE TYPES OF UNITS:I APPLICATION ■ 3 LENGTHS 1 m, 1,5 m or 2 m ELiS C air curtains are dedicated for public buildings like markets, sports halls, stores, restaurants, etc. ELiS C air curtains are designed for horizontal and vertical installation directly above door openings, where height does not exceed 3 m. 2 VERSIONS W - water heat exchanger E - electric heaters I TECHNICAL DATA Air curtains ELiS C ELiS C-W- ELiS C-E- ELiS C-W- ELiS...

Open the catalog to page 6
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 7

INSTALLATION INSTALLATION PLATE ELiS C air curtains are equipped with installation plate which allows horizontal installation above the door. PINS ELiS C air curtains can be mounted using installation pins. BRACKET MPK Possibility of vertical installation of ELiS C air curtains using brackets. For CAD drawings, Revit files and documentation for all available versions of ELiS visit www.flowair.com connection interior thread ELiS • air curtains and air curtain-fan heater units

Open the catalog to page 7
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 8

CONNECTION DIAGRAM TS CONTROLLER TS TS – 3-step fan speed controller with thermostat DCet – magnetic door sensor with relay box DCm – mechanical door sensor SRQ – valve with actuator ELiS C is compatible with T-box controller power supply ELiS C – EASY INSTALLATION

Open the catalog to page 8
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 9

V - air flow PT - heating capacity Tp1 - inlet air temperature Tp2 - outlet air temperature Tw1 - inlet water temperature Tw2 - outlet water temperature Qw - water flow in the heat exchanger Apw - water pressure drop in the heat exchanger HEAT POWER CALCULATOR l_ Select a device for different parameters, scan QR code ELiS • air curtains and air curtain-fan heater units 9

Open the catalog to page 9
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 10

Casing Steel, EPP, plastic, aluminium (1) According to ISO 27327-1 (2) For T-W at inlet/outlet water temperature 90/70oC, inlet air temperature 10oC (3) RAL 9007 I AVAILABLE TYPES OF UNITS: I APPLICATION 3 LENGTHS 1 m, 1,5 m or 2 m Modern shape and small size makes it suitable to install the units both in representative and industrial buildings. ELiS T air curtains are designed for both horizontal mounting - directly above the door openings - and vertical mounting on the side parts of the door opening. 3 VERSIONS W - water heat exchanger (1- or 2-rows) N - without heating elements...

Open the catalog to page 10
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 11

INSTALLATION CONSOLE Optional installation console enables easy and quick installation of the air curtain on the wall in two ways. PINS ELiS T air curtains can be mounted using installation pins. BRACKET MPK Possibility of vertical installation of ELiS T air curtains using brackets. CAD drawings and documentation for all available versions of ELiS visit www.flowair.com 377 428 the dimension refers to a curtain with an ELiS T-W exchanger ELiS • air curtains and air curtain-fan heater units

Open the catalog to page 11
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 12

CONNECTION DIAGRAMS TS CONTROLLER T-box CONTROLLER DRV ELiS LIYCY-P 2x2x0,5 mm2 A and B braided wire pair max. 50 m power supply TS – 3-step fan speed controller with thermostat DCet – magnetic door sensor with relay box DCm – mechanical door sensor SRQ – valve with actuator power supply ELEMENTS: T-box – intelligent controller with touch screen DRV ELiS – external control module DCe – magnetic door sensor DCm – mechanical door sensor SRQ – valve with actuator ELiS T – UNIVERSAL INSTALLATION OPTION 12

Open the catalog to page 12
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS - 13

V - air flow PT - heating capacity Tp1 - inlet air temperature Tp2 - outlet air temperature Tw1 - inlet water temperature Tw2 - outlet water temperature Qw - water flow in the heat exchanger Apw - water pressure drop in the heat exchanger 0S&0 HEAT POWER CALCULATOR Select a device for different parameters, scan QR code. ELiS • air curtains and air curtain-fan heater units 13

Open the catalog to page 13