Catalog excerpts
Smoke Master SMPA Compact pressurisation system
Open the catalog to page 1TECHNICAL DATA Flakt Woods FILO EN 2009.07 2 All rights reserved
Open the catalog to page 2TECHNICAL DATA Fläkt Woods
Open the catalog to page 3TECHNICAL DATA 3 SMPZ-2 SMOKE MASTER SMPA is an all-inclusive total solution for exit route pressurisation. The system has been designed and the components constructed to meet the EN 12101-6 requirements. The system has been subjected to a variety of tests at Fläkt Woods’ own laboratories. SMPA has been designed for pressurisation of exit routes of different types, such as the stairwells of residential buildings, underground exit routes, and the exit routes from car parks. The SMPA-1 fan unit is available with three sizes which makes it suitable for use over a wide range of air volumes. Due...
Open the catalog to page 4TECHNICAL DATA Design and operation General Dimensioning and quick guide The product development of the SMPA pressurisation system has accounted for the EN-12101-6, (RIL 232-2007) requirements and different pressurisation classes. In practice, projects need to pay special attention to choosing the correct pressurisation class, because different pressurisation classes will result in very different pressurisation air flows. There are many things that affect the choice of pressurisation class, such as the size of the building and the instructions for exit. The pressurisation class should...
Open the catalog to page 5TECHNICAL DATA Technical specification Dimensions Fan unit: The outer and inner casings are made of galvanized steel sheet and the shroud has 100 mm mineral wool insulation. The smoke hatches are made of galvanized steel sheet and insulated with mineral wool. Fläkt Woods
Open the catalog to page 6TECHNICAL DATA Electric and control equipment General: SMPA electric connection data Every SMOKE MASTER SMPA system comes with the necessary electric and control equipment. The SMPA basic package includes the following electric and control equipment: • control unit SMPZ-2 • control panel SMPZ-3 • differential pressure transmitter SMIZ-4 • safety switches Control unit SMPZ-2 • junction box • frequency converter • automatic control system Wiring diagram and electric connections SMPA CONTROL UNIT Supply cable FREQUENCY CONVERTER PRESSURE ”RUN” SIGNAL TRANSMITTER dPT 01 CONTROL PANEL 2,2 kohm...
Open the catalog to page 7TECHNICAL DATA Electric and control equipment Control panel SMPZ-3 • for controlling pressurisation • with indicator lights PRESSURISATION STANDBY Differential pressure transmitter SMIZ-4 • for controlling the fan • to be installed in the stairwell Smoke detector FDRC-2-SMIA (Optional extra) Fläkt Woods
Open the catalog to page 8TECHNICAL DATA Apartment air release path General Pressurisation without apartment air release path For proper operation of the pressurisation system, there must be an automatically opening air release path in the smoke detector is activated, allowing gases to escape outside. The air release path shall be located near the apartment entrance to prevent interior doors, etc. from restricting the gas flow. The air release path can be a window, a smoke extraction damper, or other appropriate solution. A key design principle to consider is that the minimum free area of the air release path shall...
Open the catalog to page 9TECHNICAL DATA Installation These instructions are also supplied with every SMPA system. For more information, please contact your local Fläkt Woods dealer. Fläkt Woods
Open the catalog to page 10TECHNICAL DATA Installation and Product code Product code Optional extras: Pressurisation and smoke exhaust system SMPA-aaa Smoke detector Size (cm) 040, 050, 063 The basic package includes: Fan unit Control unit Control panel Differential pressure transmitter Component codes (when ordering individual components): Fan unit Size (cm) 040, 050, 063 Control unit Size (cm) 040, 050, 063 Control panel Differential pressure transmitter Fläkt Woods
Open the catalog to page 11We Bring Air to Life Fläkt Woods is a global leader in air management. We specialise in the design and manufacture of a wide rande of air climate and air movement solutions. And our collective experience is unrivalled. Our constant aim is to provide systems that precisely deliver required functions and performance, as well as maximise energy efficiency. Solutions for all your air climate and air movement needs Fläkt Woods is providing solutions for ventilation and air climate for buildings as well as fan solutions for industry and infrastructure. Air Handling Units (AHUs) Modular, compact...
Open the catalog to page 12All FLAKT WOODS catalogs and technical brochures
-
SK1 TRANSFER AIR DEVICE
1 Pages
-
KGFC EXHAUST AIR VALVE
1 Pages
-
PWKA SQUARE SWIRL DIFFUSER
1 Pages
-
ERMA MEASURING DEVICE
1 Pages
-
HT SMHA HATCH
1 Pages
-
AP BIO Air Purification Unit
2 Pages
-
AP BIO Air Purifier
1 Pages
-
AP BIO
2 Pages
-
AIR PURIFIER AP BIO
12 Pages
-
ROOF UNITS HIGH TEMPERATURE (HT)
32 Pages
-
UV-C
2 Pages
-
ILOX 59Plus CREATING SPACE
4 Pages
-
AIR HANDLING UNIT ILOX 59PLUS
12 Pages
-
ILOX 59PLUS
2 Pages
-
Aerofoil Axial Flow Fans
20 Pages
-
Heat recovery unit RDAS
6 Pages
-
THE ErP DIRECTIVE
5 Pages
-
Product Range-Fans
11 Pages
-
JM Plate - Plate Axial Fans
8 Pages
-
JM Aerofoil - Cased Axial Fans
58 Pages
-
Jetfoil - Tunnel Fans
16 Pages
-
stef_stof_technical_brochure
24 Pages
-
Catalogue Roof Fan STOF
76 Pages
-
Shutter Roof
2 Pages
-
Vertical Roof
2 Pages
-
Technical Catalogue
28 Pages
-
Centriflow Plus PM
2 Pages
-
Centrimaster GT-1
5 Pages
-
Air curtain
12 Pages
-
Veloduct
66 Pages
-
Heat recovery unit RDKG
4 Pages
-
Plate diffuser KHLA
6 Pages
-
Ventilation solutions
7 Pages
-
Axial Fans
128 Pages
-
Box Fans
8 Pages
-
Air Curtains Range
46 Pages
-
Exhaust air diffuser EYMA-2
6 Pages
-
Snow screen LSJ
3 Pages
-
ClimaFläkt
93 Pages
-
Econet Compact
8 Pages
-
Box Section Express 2012
9 Pages
-
iQ Star Stella
12 Pages
-
Combi Cooler
8 Pages
-
EXPRESS CATALOGUE 2012
47 Pages
-
ATD Unit Heater - AEROTEMPER®
56 Pages
-
OPTIMIX
4 Pages