Regulation and shut-off damper SPB and SPC
10Pages

{{requestButtons}}

Catalog excerpts

Regulation and shut-off damper SPB and SPC - 1

Regulation and shut-off damper SPB and SPC SPB / SPC -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems.

Open the catalog to page 1
Regulation and shut-off damper SPB and SPC - 2

Regulation and shut-off damper SPB and SPC Area of application Multi leaf dampers are used as regulation, shut-off and mixing dampers in air handling systems and units. Properties • SPB-1 • SPB-3 • SPB-3L • SPB-3LE • SPB-4L • SPB-4LE regulation damper for balancing air flows - leakage class: 1 (CEN) - leakage class of casing: B regulation and shut-off damper to be used where low leakage is required - leakage class: 3 (CEN) - leakage class of casing: C shut-off damper to be used where low leakage and effective thermal insulation are required - leakage class: 3 (CEN) - leakage class of...

Open the catalog to page 2
Regulation and shut-off damper SPB and SPC - 3

Regulation and shut-off damper SPB and SPC TECHNICAL DATA The difference between widths and heights of available damper sizes is 10 mm. If the face surface is larger than 5 m2, the damper is put together of two or more units. Construction and dimensions are agreed on separately. Dimensions Width B Height H B x H Dampers with flange joints are equipped with Ø5 mm screw holes with 200 mm spacing to enable the mounting e.g. to wall surface without a counterflange. base for motor moottorialusta The multi leaf damper is also available with a protective cover for the lever mechanism. The...

Open the catalog to page 3
Regulation and shut-off damper SPB and SPC - 4

Regulation and shut-off damper SPB and SPC Motor torque TECHNICAL DATA Max. allowable pressure difference 3000 The torque used depends e.g. on the type, width and length of the multi leaf damper, the total length of the sealing surfaces and the mounting method. The motor torque required for the shut-off function of SPB-3 and SPB-4 and the recommended motor type are shown in the tables below. 10 Nm ACTUATOR 20 Nm ACTUATOR 30 Nm ACTUATOR Fläkt Woods Specifications are subject of alteration without further notice

Open the catalog to page 4
Regulation and shut-off damper SPB and SPC - 5

Regulation and shut-off damper SPB and SPC Sound power level LW Face surface area of damper (m2) The sound power levels of the duct for every octave band are obtained by adding the corrections Koct of octave bands and KA of the face surface (see tables above) to the total sound pressure level Lp10A, dB(A), according to the following formula: Medium frequency of octave band (Hz) 63 Sound power level LW in duct when damper closed Correction Koct is the average in the area of application of SPB. Face surface velocity v (m/s) Medium frequency of octave band (Hz) 63 TECHNICAL DATA Face surface...

Open the catalog to page 5
Regulation and shut-off damper SPB and SPC - 6

Regulation and shut-off damper SPB and SPC TECHNICAL DATA SPC-3 • leakage class: 3 (CEN) • leakage class of casing: C • no thermal insulation SPC-3L • leakage class: 3 (CEN) • leakage class of casing: C • blades thermally insulated with mineral wool • heat transmission Um = 4,5 W/m2K Due to its moderate need for space and its excellent mixing performance, SPC is very well suited e.g. for the mixing damper of an air hamdling unit. SPC-3LE • leakage class: 3 (CEN) • leakage class of casing: C • blades and casing thermally insulated with mineral wool (outer dimensions B+120, H+60) • heat...

Open the catalog to page 6
Regulation and shut-off damper SPB and SPC - 7

Regulation and shut-off damper SPB and SPC Product code TECHNICAL DATA Sound power level LW Medium frequency of octave band (Hz) Face surface area of damper (m2) Nominal size AAA = nominal width mm BBB = nominal height mm Joint 0 = slip joint 1 = flange joint 2 = circular joint (D1) 3 = circular joint on both sides (D2) Material 0 = galvanized steel 1 = acid-proof steel Equipment 1 = protective cover for gear unit + base for motor Operation 0 = without accessories 1 = manual regulator 2 = regulator with extension, length 1500 mm 3 = damper motor installed (the motor must be ordered on a...

Open the catalog to page 7
Regulation and shut-off damper SPB and SPC - 8

Regulation and shut-off damper SPB and SPC TECHNICAL DATA Face surface velocity v (m/s) Face surface velocity v (m/s) Definitions air volume souns pressure level with 4 dB room attenuation (10 m2sab) sound power level by octave bands correction total pressure drop static pressure drop average velocity (m/s) correction of face area heat transmission Face surface velocity v (m/s) Fläkt Woods Specifications are subject of alteration without further notice

Open the catalog to page 8
Regulation and shut-off damper SPB and SPC - 9

Regulation and shut-off damper SPB and SPC TECHNICAL DATA Flakt Woods Specifications are subject of alteration without further notice.

Open the catalog to page 9
Regulation and shut-off damper SPB and SPC - 10

We Bring Air to Life Fläkt Woods is a global leader in air management. We specialise in the design and manufacture of a wide rande of air climate and air movement solutions. And our collective experience is unrivalled. Our constant aim is to provide systems that precisely deliver required functions and performance, as well as maximise energy efficiency. Solutions for all your air climate and air movement needs Fläkt Woods is providing solutions for ventilation and air climate for buildings as well as fan solutions for industry and infrastructure. Air Handling Units (AHUs) Modular, compact...

Open the catalog to page 10

All FLAKT WOODS catalogs and technical brochures

  1. AP BIO

    2 Pages

  2. UV-C

    2 Pages

  3. ILOX 59PLUS

    2 Pages

  4. Shutter Roof

    2 Pages

  5. Air curtain

    12 Pages

  6. Veloduct

    66 Pages

  7. Axial Fans

    128 Pages

  8. Box Fans

    8 Pages

  9. ClimaFläkt

    93 Pages

  10. iQ Star Stella

    12 Pages

  11. Combi Cooler

    8 Pages

  12. OPTIMIX

    4 Pages