JM Plate - Plate Axial Fans
8Pages

{{requestButtons}}

Catalog excerpts

JM Plate - Plate Axial Fans - 1

Axial Fans Catalogue (50Hz) JM Plate - Plate Axial Fans Features • 315 - 630 mm diameter • Volume up to 14,688 m /h (4.08m /s) • Static pressures up to 175 Pa • Motor protection IP55 • Speed controllable • Supplied fully assembled • Full range of accessories • Inverter speed controllable 3 Temperature Range • -40ºC to 50ºC as standard Product Code Plate Plates Manufactured from mild steel with powder coat finish, fans are supplied as standard with motor side guard. Motors All motors are totally enclosed airstream rated class F insulation. Constructed from aluminium as standard with special ‘T’ slot fixings. Suitable for horizontal through to vertical shaft operation. Supplied IP55 with removable drain plugs. These motors are suitable for inverter speed control down to 20% of full speed. 63 - denotes the Fan impeller diameter in centimetres JMP - denotes Plate Fan Type 20 - denotes impeller hub diameter in centimetres 4 - denotes a nominal 4 Pole speed 6 - denotes the number of blades 24 - denotes the Pitch Angle for the required duty Impellers A unique high efficiency aerofoil section blade. The Fläkt Woods impellers are all high pressure die cast to offer thin aerofoil sections for low generation of noise. Every cast aluminium component is X-ray examined using Real Time Radiography inspection prior to assembly. The maximum pitch angles shown allow for speed control by frequency inverter. Lourve Shuttes Imepller side Guard Controls Transformer Controls Inverter Controls Electronic Fläkt Woods Limited (UK) Specifications are subject of alteration without further notice

Open the catalog to page 1
JM Plate - Plate Axial Fans - 2

Axial Fans Catalogue (50Hz) Product Performance and Electrical Data Performance Chart - JM Plate 220-240v/50Hz/1f 220-240v/50Hz/1 Performance Chart - JM Plate Performance Table - JM Plate 220-240v/50Hz/1f Product Code Sound pressure levels quoted are at the inlet, and are average dBA at 3m distance over a sphere at the mid point at the highest angle given, under free field conditions. These are presented for comparative purposes only. Fläkt Woods Specifications are subject of alteration without further notice

Open the catalog to page 2
JM Plate - Plate Axial Fans - 3

Axial Fans Catalogue [50Hz] Product Performance and Electrical Data oEo Product, Electrical and ErP Table - JM Plate Sound pressure levels quoted are at the inlet, and are average dBA at 3m distance over a sphere at the mid point at the highest angle given, under free field conditions. These are presented for comparative purposes only. Specifications are subject of alteration without further notice

Open the catalog to page 3
JM Plate - Plate Axial Fans - 4

Axial Fans Catalogue (50Hz) Product Performance and Electrical Data Performance Chart - JM Plate 380-420v/50Hz/3φ JM Platemounted Performance Chart - JM Plate 3 Phase 380-420v/50Hz/3f 300 Volume Flow Performance Table - JM Plate 380-420v/50Hz/3f m3/h at Pa (Static) Product Code Sound pressure levels quoted are at the inlet, and are average dBA at 3m distance over a sphere at the mid point at the highest angle given, under free field conditions. These are presented for comparative purposes only. Fläkt Woods Specifications are subject of alteration without further notice

Open the catalog to page 4
JM Plate - Plate Axial Fans - 5

Axial Fans Catalogue (50Hz) Product Performance and Electrical Data Product, Electrical and ErP Table - JM Plate 380-420v/50Hz/3f Speed Controller Full Load Current (A) Product Code Product Number Speed rev/min Product Code Product Number Inlet Sound Levels Efficiency Rating Electronic Transformer Sound pressure levels quoted are at the inlet, and are average dBA at 3m distance over a sphere at the mid point at the highest angle given, under free field conditions. These are presented for comparative purposes only. Fläkt Woods Specifications are subject of alteration without further notice

Open the catalog to page 5
JM Plate - Plate Axial Fans - 6

Axial Fans Catalogue (50Hz) Aluminium frames, plastic shutters. Shutters must be separated from the fan mounting plane by the following minimum distances: Up to 500 mm Ø – 150 mm 560 to 710 mm Ø – 200 mm 800, 1000 mm Ø – 275 mm Note; that under some combinations of fan speed and wind the shutters vanes may become unstable. This is more likely to occur at reduced fan speed. Motor Range All dimensions in mm Fläkt Woods Limited (UK) Specifications are subject of alteration without further notice

Open the catalog to page 6
JM Plate - Plate Axial Fans - 7

Axial Fans Catalogue [50Hz] Wiring Diagrams - JM Plate REMOVE DOTTED LINK EACH DIAGRAM RESETTABLE DEVICE [IF APPLICABLE REMOVE LINK A AND CONNECT LIVE WIRE 'UZ' FROM THE SPEED CONTROLLER TO FAN CONNECTED TO SUPPLY (FULL SPEED) FAN CONNECTED TO SPEED CONTROLLER (VARIABLE SPEED) CIRCUITS WHEN FITTED: THERMAL PROTECTION THREE PHASE SUPPLY COUNTER CLOCKWISE: REVERSE (LI) AND (L2) Specifications are subject of alteration without further notice

Open the catalog to page 7
JM Plate - Plate Axial Fans - 8

Axial Fans Catalogue [50Hz] Wiring Diagrams - JM Plate CIRCUITS WHEN FITTED: THERMAL PROTECTION THREE PHASE SUPPLY COUNTER CLOCKWISE: REVERSE (LI) AND (L2) Specifications are subject of alteration without further notice

Open the catalog to page 8

All FLAKT WOODS catalogs and technical brochures

  1. AP BIO

    2 Pages

  2. UV-C

    2 Pages

  3. ILOX 59PLUS

    2 Pages

  4. Shutter Roof

    2 Pages

  5. Air curtain

    12 Pages

  6. Veloduct

    66 Pages

  7. Axial Fans

    128 Pages

  8. Box Fans

    8 Pages

  9. ClimaFläkt

    93 Pages

  10. iQ Star Stella

    12 Pages

  11. Combi Cooler

    8 Pages

  12. OPTIMIX

    4 Pages