Catalog excerpts
Fläkt Woods Experience at your Service Fläkt Woods is one of the worldwide leaders in the air movement. Our expertise and skills in the design and manufacture of high technological equipment enable us to offer high level integrated solutions. Within Fläkt Woods issues such as energy efficiency as well as respect and protection of the Environment are of a great importance for us and the experience we gained has no comparison. Our expertise and our reputation have been built up on a century of innovation and engineering development, thus leaving a remarkable footmark from which arises the...
Open the catalog to page 2Shops, stores, shopping centres, hotel halls as well as industrial buildings are the typical examples where the continuous opening of the doors causes an exchange between the inside and outside air, thus originating sudden temperature changes. Consequently it is evident the need to keep the two environments separated without renouncing however to a clear entrance inviting to pop in. Fläkt Woods Air Curtains are the ideal solution for this: in winter warmth is retained inside and so is for the air conditioning in summer while rejecting dust, smoke, insects and bad smell from the outside. Air...
Open the catalog to page 3Electrical heating Water heating Without heating FEATURES: - Visible or recessed installation - Available in different colours - Version for cooling water available Heating output: AC-Linea Heights up to 5 metres APPLICATIONS Suitable for all commercial applications Heating output: AC-Comfort Heights up to 5 metres FEATURES: - Maintenance free - Elegant front panel with integrated slots - Available in different colours APPLICATIONS Suitable for all commercial applications where high performances and good design is required Heating output: AC-Comfort Flat Heights up to 3.5 metres 4 FEATURES:...
Open the catalog to page 4Horizontal installation Vertical installation Recessed installation FEATURES: - Oval design - Many options available - Available in different colours Heating output: AC-Elite Oval Heights up to 3,5 metres APPLICATIONS Suitable for all commercial applications where high performances and a stylish solutions is needed FEATURES: - Rounded design - Many options available - Available in different colours Heating output: AC-Elite Round Heights up to 5 metres APPLICATIONS Suitable for all commercial applications where high performances and a stylish solutions is needed FEATURES: - Wing spread...
Open the catalog to page 5Water heating Electrical heating Without heating Horizontal installation Vertical installation Recessed installation Heating output: AC-Industrial Heights up to 6 metres FEATURES: - No need of dust filter - Special painting for high resistance - Frost protection available as option APPLICATIONS Suitable for big opening like factories, hangars, big warehouses and similar FEATURES: - Visible or recessed installation - Two different supply throw - High energy savings - Available in different colours - Version for cooling water available Heating output: from 10.5 to 70.7 kW Soft industrial...
Open the catalog to page 6Distance from the supply Air velocities at different heights* ACAC-Elite AC-Elite Oval Comfort Round Flat AC-Elite Alas ACACAxiplus Doublejet 6m * Speed values are referred to models suitable to be installed at maximum height
Open the catalog to page 7Air Curtains AC-LINEA RANGE Three types: water heating, electrical heating and air only version (ambient) Airflow up to 16,900 m3/h Mounting heights of up to 5 metres Plug & Play versions with pre-wired control panel AC-Linea air curtains are available for horizontal mounting above openings. Mounting heights range from 2.5 to 5 metres. The air curtain is suitable for all commercial applications: shops, ofces, shopping centres and hotels. AC-Linea range includes ve types of air curtains (S - M - G - B - BB) available in lengths of 1, 1.5, 2, 2.5 and 3 metres (the last length is available as...
Open the catalog to page 8Technical specications - “Ambient” version Model Electrical supply Volt/Hz/ph Technical specications - Electric heating version Model Electrical supply Volt/Hz/ph * Free field sound pressure level measured at 3 metres at max. and minimum speed. Air curtains with electric heater are equipped with a 3-level overheating security system.
Open the catalog to page 9Technical specications - Water heating version (LPHW 90/70°C and 80/60°C) LPHW 90/70°C Heat. ΔP ΔT capac. kPa °C kW 14.3 9.5 18-52 LPHW 80/60°C Heat. ΔP ΔT capac. kPa °C kW 11.9 7.1 18-47 Electrical supply Volt/Hz/ph Technical specications - Water heating version for low temperature climates (LPHW 90/70°C and 80/60°C) LPHW 90/70°C Heat. ΔP ΔT capac. kPa °C kW 19.9 27.0 18-63 LPHW 80/60°C Heat. ΔP ΔT capac. kPa °C kW 16.5 19.7 18-56 Electrical supply Volt/Hz/ph * Free field sound pressure level measured at 3 metres at max. and minimum speed.
Open the catalog to page 10Technical specications - Water heating version (LPHW 70/50°C and 70/35°C) LPHW 70/50°C Heat. ΔP ΔT capac. kPa °C kW 9.5 4.8 18-41 LPHW 70/35°C Heat. ΔP ΔT capac. kPa °C kW 6.6 1.2 18-34 Electrical supply Volt/Hz/ph Technical specications - Water heating version for low temperature climates (LPHW 70/50°C and 70/35°C) LPHW 70/50°C Heat. ΔP ΔT capac. kPa °C kW 13.2 13.4 18-48 Electrical supply Volt/Hz/ph LPHW 70/35°C Heat. ΔP ΔT capac. kPa °C kW 9.7 2.8 18-40 * Free field sound pressure level measured at 3 metres at max. and minimum speed.
Open the catalog to page 11Technical specications - Water heating version (LPHW 60/40°C and 45/35°C) LPHW 60/40°C Heat. ΔP ΔT capac. kPa °C kW 7.3 3.1 18-35 LPHW 45/35°C Heat. ΔP ΔT capac. kPa °C kW 5.1 5.5 18-30 Electrical supply Volt/Hz/ph Technical specications - Water heating version for low temperature climates (LPHW 60/40°C and 45/35°C) LPHW 60/40°C Heat. ΔP ΔT capac. kPa °C kW 9.8 8,0 18-40 Electrical supply Volt/Hz/ph LPHW 45/35°C Heat. ΔP ΔT capac. kPa °C kW 6.8 14.9 18-34 * Free field sound pressure level measured at 3 metres at max. and minimum speed.
Open the catalog to page 12All FLAKT WOODS catalogs and technical brochures
-
SK1 TRANSFER AIR DEVICE
1 Pages
-
KGFC EXHAUST AIR VALVE
1 Pages
-
PWKA SQUARE SWIRL DIFFUSER
1 Pages
-
ERMA MEASURING DEVICE
1 Pages
-
HT SMHA HATCH
1 Pages
-
AP BIO Air Purification Unit
2 Pages
-
AP BIO Air Purifier
1 Pages
-
AP BIO
2 Pages
-
AIR PURIFIER AP BIO
12 Pages
-
ROOF UNITS HIGH TEMPERATURE (HT)
32 Pages
-
UV-C
2 Pages
-
ILOX 59Plus CREATING SPACE
4 Pages
-
AIR HANDLING UNIT ILOX 59PLUS
12 Pages
-
ILOX 59PLUS
2 Pages
-
Aerofoil Axial Flow Fans
20 Pages
-
Heat recovery unit RDAS
6 Pages
-
THE ErP DIRECTIVE
5 Pages
-
Product Range-Fans
11 Pages
-
JM Plate - Plate Axial Fans
8 Pages
-
JM Aerofoil - Cased Axial Fans
58 Pages
-
Jetfoil - Tunnel Fans
16 Pages
-
stef_stof_technical_brochure
24 Pages
-
Catalogue Roof Fan STOF
76 Pages
-
Shutter Roof
2 Pages
-
Vertical Roof
2 Pages
-
Technical Catalogue
28 Pages
-
Centriflow Plus PM
2 Pages
-
Centrimaster GT-1
5 Pages
-
Air curtain
12 Pages
-
Veloduct
66 Pages
-
Smoke Master SMPA
12 Pages
-
Heat recovery unit RDKG
4 Pages
-
Plate diffuser KHLA
6 Pages
-
Ventilation solutions
7 Pages
-
Axial Fans
128 Pages
-
Box Fans
8 Pages
-
Exhaust air diffuser EYMA-2
6 Pages
-
Snow screen LSJ
3 Pages
-
ClimaFläkt
93 Pages
-
Econet Compact
8 Pages
-
Box Section Express 2012
9 Pages
-
iQ Star Stella
12 Pages
-
Combi Cooler
8 Pages
-
EXPRESS CATALOGUE 2012
47 Pages
-
ATD Unit Heater - AEROTEMPER®
56 Pages
-
OPTIMIX
4 Pages