Open the catalog to page 1Contents Page General Product Range/ Technical Data Coating / Colour Surface Design Stress analysis, Licence Corrosion Protection Thermal Insulation Quality Assurance Noise Insulation Fire Resistance Lightning Protection Sealed Jointing Quality Assessment and Assurance Longitudinal Jointing Design / End Lap Jointing Design Special Features Fastening Details Panel Fixings Minimum Roof Pitch FischerTHERM DL Foam-free area, longitudinal lap jointing Jointing 24 Assembly Instructions
Open the catalog to page 3FischerTHERM – Efficiency and Quality Fischer Profil GmbH is one of the leading European manufacturers of pre-assembled wall, roof and decking components. Fischer Profil has extensive know-how in manufacturing and construction technique. Qualified advice with a customer orientated service forms an integral part of our company policy. The “FischerTHERM” sandwich panels are also a part of the manufacturing programme. We offer a wide variety of FischerTHERM wall and roof panels: Wall panels: FischerTHERM LL as a standard panel FischerTHERM plus SL and ML with concealed fasteners FischerTHERM TL...
Open the catalog to page 4FischerTHERM TL, with its trapezoidally profiled outer-skin, has a special visual appearance and greater rigidity. FischerTHERM DL elements are available up to a max. length of 26,5 m. FischerTHERM DL roof panels with their broad valley make it easy to walk over them during mounting. An increased longitudinal lap with additional grooves prevents the penetration of surface water. Optically the FischerTHERM plus SL, ML is a particularly elegant wall cladding element due to its concealed fasteners (within the element) and optionally its fine beading and/or micro-lining of the outer skin. With FischerTHERM...
Open the catalog to page 5FischerTHERM – Product Range FischerTHERM1.)* Wall clading elements Roof elements FischerTHERM plus * From 1000 m² also available in 1000 mm construction width. Please enquire about coating/colour. ** Trapezoidally profiled outer skin available in construction width of 800 mm. ) Other combinations of surface designs see brochure FischerTHERM page 7. 1. Panel Type sheet thickness t [mm] outerskin innerskin ta [mm] ti [mm] FischerTHERM LL40 LL60 LL 80 LL100 FischerTHERM plus On request, FischerTHERM roof elements are available with an additional sealing strip in the longitudinal joint. heat transmission...
Open the catalog to page 6Possible combinations of surface designs Note: 1st letter = outside Only Colorcoat HPS 200 Ultra should be used for the outer skin of the EE and EL com-
Open the catalog to page 7FischerTHERM – Coatings and colours Outside Beschichtungen / Farbton White Goosewing Grey Terracotta Hamlet Merlin Grey Heritage Green Anthracite Petra Colorcoat Prisma, 50 µm Red Oxide Grey White Sirius ähnlich Orion ähnlich Light Ivory RAL 1015 1)4) Rubinrot RAL 3003 1) Gention blue RAL 5010 1) Sky blue RAL 5015 Moorland Green RAL 6005 Reseda Green RAL 6011 Chromium oxide green RAL 6020 Anthracite 4) RAL 7016 4) Light Grey RAL 7035 Dust Grey RAL 7037 Copper RAL 8004 Nut brown RAL 8011 1) Reddish brown RAL 8012 4) Grey White RAL 9002 2)4) Grey White RAL 9002 3) White Aluminium RAL 9006 3) Grey...
Open the catalog to page 8Special coatings The planning of a building envelope starts with the selection of a sustainable, state of the art coating system. The two new coating systems, Colorcoat HPS 200 Ultra and Colorcoat Prisma, combine corrosion resistance with the functionality and aesthetics of a building envelope and provide excellent colour fastness. Colorcoat Prisma with a layer thickness of 50 µm has been developed to withstand environmental influences and is distinguished by its low weight, high durability and versatility. This coating excels by virtue of its excellent colour and gloss fastness and optimum corrosion...
Open the catalog to page 9FischerTHERM – high insulation panels Thermal Insulation Thermal insulation is important for the following reasons: it lessens heat loss through the walls and roof it helps maintain the correct air balance for the building`s occupants it protects the building itself against the damaging effects of damp it lessens energy consumption for heating and cooling it keeps production and management costs down. In accordance with the energy saving decree (En EV 2002), since 1st February 2002 new, stiffer insulation requirements - particularly pertaining to walls and roofs - have had to be fulfilled including...
Open the catalog to page 10e.g. FischerTHERM wall-cladding elements are not connected to each other in such a way that they will conduct electricity, but if the metal sub-structure is connected so that it conducts from the connection to the wall panels to the connection to the earthing system without interruption, then this can be used as a conductor. One particular advantage of the registered utility model male/female jointing of FischerTHERM elements is that the nominal width of the joint need no longer necessarily be adhered to. Even in the case of the assembly being not quite exact, a very high degree of joint sealing...
Open the catalog to page 11Rigid polyurethane foam, CFC and HCFC-free. Not harmful to the environment and no damage to the ozone layer. Extra profiling for protection against heavy rainfall. Continuous sealing strip as thermal insulation Large radii of bend for greater security with 25 µm coated material. 2 A new kind of joint sealant with soft elastic sealing strip plus EPDM sealing profile for extremely tight sealing while applying little pressure. Jointing conductivity coefficient a on wall element LL40 was, instead of 8, even with 11 mm wide longitudinal joint < 0.02 m³(h·m·(10PA)n. State of the art is on a value of...
Open the catalog to page 12Fastening Your FischerTHERM Wall Panels self-drilling screw
Open the catalog to page 13FischerTHERM – Panel Fixing Requirements Examples of element fastening for FischerTHERM The examples show possible fastener arrangements but they do not replace a structural analysis of the connections. FischerTHERM LL 40, 60, 80, 100, 2 Self-sealing screws per rail, near the male-female jointing FischerTHERM LL 40, 60, 80, 100, 3 Self-sealing screws per rail FischerTHERM plus SL 60, 80, 100/ML 60 ,80,100 (with load distributors), 1 Self-sealing screw per rail or 2 sealing screws 40 mm below eacht other FischerTHERM plus SL 60, 80, 100/ML 60, 80, 100 (with load distributors), 2 Self-sealing screws...