Catalog excerpts
FischerTHERM plusdach * An enterprise of Tata Steel
Open the catalog to page 1FischerTHERM plusdach – concealed fastening The FischerTHERM plusdach roof, with the Fischer plus-rail The sheet thick-ness of the plus-rail is 0.75 mm, weight 0.69 kg/m. Standard length 5000 mm. 39,6 It is even possible to produce a Fischer1 THERM plusdach roof by subsequently adding the plus-rail and spherical caps. R1 roof elements with the additional aesthetic appeal of the concealed sealing screws. If fastening is performed in the crown, spherical caps are placed on the sealing screws in the purlin area. This is also the case with the longitudinal joint connection, spaced at ≤ 750 mm....
Open the catalog to page 3FischerTHERM plusdach - Easy to install Butt jointed or overlapping However, if the roof has a low eaves height or the eaves can easily be seen due to a large roof pitch, the end flashing of the eaves should be mounted over the prof the eaves should be mounted over the plus-rail for optical reasons. (see detail page 9, top left). Fischer plus rail butt jointed With the aid of spacers, the higher edge profiles overlap the plus-rail, for example, on the ridge. (see detail page 9)improved optical appeal through concealed sealing screws additional safety through two sealing levels Fischer plus...
Open the catalog to page 4The FischerTHERM plusdach roof can be assembled easily and quickly. Sealing screws with spherical caps are attached to the crown of the FischerTHERM roof elements for clip fastening the Fischer plus-rail. In order to facilitate the alignment of the spherical caps, these are first measured up and placed in the gable verge area of the roof surface. A uniform distance of the remaining spherical caps is achieved using a piece of cord. In the longitudinal jointing of the roof elements drilling screws are used spaced at a distance of ≤ 750. If additional sealing screws are used in the purlins...
Open the catalog to page 5FischerTHERM plusdach – the secure fastening Simple procedure for determining the required spherical caps and the number of Fischer plus-rails, whereby all sealing screws are concealed. a) with load (snow load): see brochure Manufacturing Programme / Load Tables FischerTHERM sheet thickness t: outerskin = 0.63 mm, innerskin = 0.55 mm Permitted purlin distances L [m]: Roof plan of purlin position For building heights over 20 m and purlin distances greater than 2 m and/ or 3.50 m, we will provide you with a static calculation. FischerTHERM elements purlin long side Edge area [a/8]**: Fischer...
Open the catalog to page 6Element fastening on FischerTHERM plusdach as per plan, page 6 Building height 0-8 m, purlin distanze ≤ 3.50 m Edge area [a/8]: in the longitudinal jointing area and on each intermediate rib 1 sealing screw incl. 1 spherical cap per purlin support longitudinal joint 100 Normal area: Only in longitudinal jointing area 1 sealing screw incl. 1 spherical cap per purlin support Building height 8-20 m, purlin distanze ≤ 2.00 m Edge area [a/8]: in the longitudinal jointing area and on each intermediate rib 1 sealing screw incl. 1 spherical cap per purlin support Normal area: Only in longitudinal...
Open the catalog to page 7FischerTHERM plusdach – Details The depicted details have been designed in such a way as to fulfil the following requirements as far as possible: few thermal bridges,as airtight as possible, rain-proof, pleasing to the eye, durable, simple to assemble, inexpensive. Fischer plus-rail butt jointed Industrial Guttering 12 6 a) Alternatively: Bend up the valley of the outer skin. One flute closer on each side of the roof is then sufficient. a) Alternatively: Bend up the valley of the outer skin. One flute closer on each side of the roof is then sufficient. 1 FischerTHERM plusdach 2 FischerTHERM...
Open the catalog to page 8Fischer plus-rail overlapping Industrial Guttering (with spacer profile / overlapping) 6 (with spacer profile / overlapping) 19 a) Alternatively: Bend up the valley of the outer skin. One flute closer on each side of the roof is then sufficient. (with spacer profile / overlapping) 22 a) Alternatively: Bend up the valley of the outer skin. One flute closer on each side of the roof is then sufficient. 1 FischerTHERM plusdach 2 Fischer plus-rail 3 Spherical cap 41-32 (aluzinc) 4 Self-sealing screw 6.3 x ... - E 16 5 End flashing, overlapping 6 Blind rivet AI/E - Ø 4,8 x 8,3 7 EPDM spacer...
Open the catalog to page 9FischerTHERM plusdach – Details Skylight connectors Skylight connectors (lengthways to the roof element) (transversally to the roof element) (fastening distance) Axial section a) Alternatively: Bend up the valley of the outer skin. One flute closer on each side of the roof is then sufficient. 1 FischerTHERM plusdach 2 Fischer plus-rail 3 Spherical cap 41-32 (aluzinc) 4 Connecting profile, special flashing 5 Z-profile 6 Drilling screw 5.5 x 25 - E 16 7 Permanently elastic strip sealant, single-sided self-adhesive,illac 20 x 4 8 Self-sealing screw 6.3 x ... - E 16 9 Self-sealing screw 6.3 x...
Open the catalog to page 10Skylight dome connection Skylight dome connection Skylight dome connection (along the element) 1 FischerTHERM plusdach 2 Fischer plus-rail 3 Spherical cap 41-32 (aluzinc) 4 Self-sealing screw 6.3 x ... - E 16 5 Permanently elastic precompressed strip sealant, single-sided self-adhesive, illmod SFI 30 x 6 - 16 6 Permanently elastic strip sealant, single-sided self-adhesive,illac 20 x 4 7 Rail, lengthwise 8 Rail, traverse 9 Skylight dome connector 10 Skylight dome 11 Drilling screw 5.5 x 25 - E 16
Open the catalog to page 11E-Mail: info@scherprol.de · http://www.scherprol.com 06.2012 Data subject to change without notice 12.2010 Data subject to change without notice Diese Informationen sind nach bestem Wissen und Gewissen erstellt worden. Tata Steel – einschließlich ihrer Tochtergesellschaften – übernimmt jedoch keine Haftung für Informationen, die which is foundals be misleading. Reproduction is prohibited. This information has been created in the knowledge and belief that it is accurate. Tata steel and its subsidiaries does not accept responsibility or liability for errors or information sich eventuell to...