Overview: The document describes the 13 Series electronic step/monostable relays, specifically types 13.61.0.024.0000 and 13.61.8.230.0000, designed for centralized control of power ON and OFF functions in residential settings.
Specifications:
  • Type 13.61.0.024.0000: Supports centralized power ON and OFF (Set/Reset).
  • Type 13.61.8.230.0000: Supports centralized power OFF (Reset).
  • Dimensions: 17.5 mm wide, 35 mm (EN 60715) mounting.
  • Electrical Rating: 1 Pole 16 A 250 V AC.
  • Nominal Voltage: 12...24 V AC/DC or 110…230 V AC (50/60Hz).
Features:
  • Multifunctionality: Includes step relay, timing step relay (20 seconds to 30 minutes), monostable relay, and light ON mode.
  • Centralized control: Allows switching OFF all lights or power circuits from a single point, typically located at the entrance or bedroom.
  • Safety: Requires a 3-second button press to prevent accidental activation.
Operation:
  • The relay can be set to one of four functions using a rotary switch.
  • Step Relay (RI): Changes state with each impulse, alternating between open and closed.
  • Timing Step Relay (IT): Closes on initial impulse, starts timing for a preset duration, and opens after the time delay. Can be interrupted with another impulse.
Applications: Ideal for centralized switching ON and OFF in residential environments, enhancing convenience and energy management.
Disclaimer: Finder reserves the right to alter characteristics without notice and assumes no liability for damages resulting from incorrect use or application of its products.
See more

Catalog excerpts

1361-1

REPORT SWITCH TO THE FUTURE Electronic step/monostable relay with centralised control of ON and OFF Type 13.61.0.024.0000 Electronic step/monostable relay with centralised OFF control Type 13.61.8.230.0000 Approvals (according to type) C€ ERE Where there is a need for centralised system switch-OFF via a single button typically placed at the entrance of the house, the new 13.61 is the simplest solution to install and connect. • Multifunction: - Step relay - Timing Step relay (20 seconds to 30 minutes) - Monostable Relay - Light ON Mode • Type 13.61.0.024.0000 - Function for centralised power ON and OFF (Set/Reset) Type 13.61.8.230.0000 - Function for centralised power OFF (Reset) • 17.5 mm wide, 35 mm (EN 60715) mounting • 1 Pole 16 A 250 V AC • Nominal voltage 12...24 V AC/DC or 110...230 V AC (50/60Hz)

 Open the catalog to page 1
1361-2

TYPE 13.61 Electronic step relay Operation The 13.61 can be set via the rotary switch to one of 4 functions: Step relay, Timed step relay, Monostable relay and Light permanently ON. With either “step relay” function, the 13.61 output relay can be switched OFF (reset) from a centralised single command, enabling all lights or power circuits that are ON, to be turned OFF from one or more central point(s) - which are typically installed next to the front door of the house or in the bedroom. To switch OFF, just press the button for 3 seconds - this time is to avoid inadvertently pressing a button...

 Open the catalog to page 2

All FINDER S.p.A catalogs and technical brochures

  1. 1T SERIES

    12  Pages

  2. 1C91_BLISS

    4  Pages

  3. 185K

    2  Pages

  4. 11 Series

    12  Pages

  5. 10 Series

    8  Pages

  6. 1571_YESLY

    4  Pages

  7. 15

    2  Pages

  8. 1372_YESLY

    4  Pages

  9. 1T51

    2  Pages

  10. 1T91_BLISS

    4  Pages

  11. 1C81

    2  Pages

  12. 1C61

    2  Pages

  13. 1C71

    2  Pages

  14. 1C51

    2  Pages

  15. S78 Series

    22  Pages

  16. 781B

    2  Pages

  17. 7851_61

    2  Pages

  18. 78

    2  Pages

  19. General catalog

    703  Pages

  20. KNX PRODUCTS

    8  Pages

  21. YESLY

    42  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.