video corpo

11 Series
12Pages

{{requestButtons}}

Catalog excerpts

11 Series - 1

Light dependent relays 12 - 16 A Garden and night lighting Shop displays Lighting for parks Streetlights and car park lighting

Open the catalog to page 1
11 Series - 2

FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.

Open the catalog to page 2
11 Series - 3

Relays for automatic control of lighting according to ambient light level - with separate light sensor 11.31 - 1 NO 16 A output contact • Sensitivity adjustment from 1 to 100 lux • One module, 17.5 mm wide • Low energy consumption • 24 V DC/AC supply version available 11.41 - 1 CO 16 A output contact • European patent "zero hysteresis” for energy saving • Italian patent "Light feedback compensation” principle • Selector with 4 positions: - Standard range (threshold setting 1...80 lx) - High range (threshold setting 30.1000 lx) - continuous light (helpful during installation and initial...

Open the catalog to page 3
11 Series - 4

11 SERIES Light dependent relays 12 -16 A Relays for automatic control of lighting according to ambient light level - with separate light sensor 11.42 - 1 CO + 1 NO 12 A output contacts • Two independent outputs with individual lux setting • Selector with 4 positions: - Standard range (threshold setting 1...80 x) - High range (threshold setting 20.1000 lx) - continuous light (helpful during installation and initial testing and for maintenance purposes) - light off (useful for vacations) • For the first 6 working cycles (in total for channels 1 & 2) the delay time (On and Off) is reduced to...

Open the catalog to page 4
11 Series - 5

Ordering information Example: 11 series light dependent relay with time switch, 1 CO (SPDT) 16 A contact, 230 V AC supply. Series Type- 3 = 17.5 mm wide 4 = 35 mm wide 9 = 35 mm wide, with time switch No. of poles- Technical data Options 0000 = Standard Supply voltage 024 = 12...24 V (11.31 only) 230=230V 230 = 110.230 V (11.31 only) 230 = (110...230)V AC/DC (11.91 only) Supply version 0 = AC (50/60 Hz)/DC (11.31 only) 8 = AC (50/60 Hz) 8 = AC (50/60 Hz)/DC (11.91 only) Codes 11.31.0.024.0000 11.31.8.230.0000 11.41.8.230.0000 11.42.8.230.0000 11.91.8.230.0000 19.91.9.012.4000 (power module...

Open the catalog to page 5
11 Series - 6

11 SERIES Light dependent relays 12 -16 A Wiring diagrams !□ L(gHJ Type 11.41 Type 11.91 i-®-|

Open the catalog to page 6
11 Series - 7

11 SERIES Light dependent relays 12 - 16 A Advantage of the “zero hysteresis” patented circuit: ensures reliable switching without wasting energy TYPE 11.41 “ZERO HYSTERESIS” LIGHT DEPENDENT RELAYS TRADITIONAL LIGHT DEPENDENT RELAYS OFF threshold ON/OFF threshold Switch OFF level = Switch ON level. Patented “zero hyseresis” circuitry ensures reliable switching without wasting energy. “Traditional” light dependent relays incorporate switching hysteresis to prevent malfunctioning or tripping. This results in an unnecessary delay in switching off, and a resulting waste of energy (over period...

Open the catalog to page 7
11 Series - 8

11 SERIES Light dependent relays 12 - 16 A Switch-OFF time Switch-ON time NO Application examples Working as a standard light-dependent relay Working where lighting is not required from 10 PM onwards Working where lighting is not required between 1 AM and 5 AM Additional output - light dependent without time switch intervention All the functions and the values can be set through the front joystick and are displayed on the front LCD. Display mode During normal operation, with AC supply connected, the following is displayed: - he current time t - he current lux level (upper bars) t - he set...

Open the catalog to page 8
11 Series - 9

11 SERIES Light dependent relays 12 Auxiliary output A solid state output at terminals Y1-Y2 is provided (rated 12 V DC, 80 mA/1 W max.): this can be used with the power module 19.91.9.012.4000 connected by the dedicated 011.19 connector. Or, it is possible to connect a suitable relay (for example, 38-48-49-4C-58-59 interface module) provided the coil is within the rating, and the wiring does not exceed 40 cm length. The auxiliary output is driven exclusively by the light sensor of the device, and is consequently independent of the time switch. With the main contact, this permits a flexible...

Open the catalog to page 9
11 Series - 10

11 SERIES Light dependent relays 12 -16 A Outline drawings 11.31 Screw terminal Screw terminal 11.91 + 19.91 power module Screw terminal

Open the catalog to page 10
11 Series - 11

11 SERIES Light dependent relays 12 Accessories Light sensor (supplied with light dependent relay) 011.02 - Ambient temperature range: -40...+70 °C - Cadmium free - Non polarized - Double insulated with respect to light dependent relay supply - Not compatible with old 11.01 and 11.71 light dependent relay (to be used with 011.00 photosensor) Flush-mounted light sensor (protection category: IP66/67) 011.03 - Ambient temperature range: -40...+70 °C - Cadmium free - Non polarized - Double insulated with respect to light dependent relay supply - Not compatible with old 11.01 and 11.71...

Open the catalog to page 11

All FINDER S.p.A catalogs and technical brochures

  1. 185K

    2 Pages

  2. 10 Series

    8 Pages

  3. 1571_YESLY

    4 Pages

  4. 15

    2 Pages

  5. 1372_YESLY

    4 Pages

  6. 1361

    2 Pages

  7. 1T51

    2 Pages

  8. 1T91_BLISS

    4 Pages

  9. 1C81

    2 Pages

  10. 1C61

    2 Pages

  11. 1C71

    2 Pages

  12. 1C91_BLISS

    4 Pages

  13. 1C51

    2 Pages

  14. S78 Series

    22 Pages

  15. 781B

    2 Pages

  16. 7851_61

    2 Pages

  17. 78

    2 Pages

  18. General catalog

    703 Pages

  19. KNX PRODUCTS

    8 Pages

  20. YESLY

    42 Pages