intoduction
24Pages

{{requestButtons}}

Catalog excerpts

intoduction - 1

Partitions fermacell The Company 5 Fire 10 Acoustics 11 Impact / Manchester, UK Location 18 Moisture 21 Case Study / Shopping Centre Oreet alisi eros nim ilit ea corperi Environmental eros nim ilit ustrud mincing alisi ea corperi ustrud mining alisi eros Product ea corperi ustruding alisi Use nim ilit eros nim ilit ea corper. COSHH Health & Safety 22 23 26

Open the catalog to page 1
intoduction - 2

FERMACELL SETTING STANDARDS Environmentally Certified Manufactured from recycled Impact Resistant Reduces double layering Eliminates Noggings. 60 mins fire resistance from single layer partitions up to 10 m high. Class '0' certification. Moisture Resistant Suitable for humid areas. May be installed before building envelope complete. Sound Insulating Simple Party Wall Ready to accept paint, wallpaper, tiles. Glued, square edge boards FST (Fine Surface Treatment) eliminates plastering trades. Modern construction needs modern materials. Design innovation combined with increasing pressure from...

Open the catalog to page 2
intoduction - 3

FERMACELI., THE MULTI-PURPOSE BOARD GENERAL PROPERTIES There are a bewildering array of construction systems and techniques to consider when specifying internal finishes. For partitions, this is most apparent when the properties required of the finished wall call for more than one type of building board to be used in the construction. Hotel bathrooms, for example, often require Moisture Resistance with Acoustic Insulation and Fire Protection. Hospitals will add Impact Resistance and flexibility in accepting wall mounted fittings to this. These criteria almost always demand compromise...

Open the catalog to page 3
intoduction - 4

FERMACELL FOR WALLS AND CEILINGS Fermaceli is available in standard sizes as well as custom formats Wallboard thicknesses range from 10 mm to 18 mm. This choice gives both specifier and installer the ability to select the most appropriate product to speed installation and eliminate waste. ONE-MAN BOARD One-man boards are available in 1200 x 800, STANDARD SIZE BOARDS Standard size boards in thicknesses from 10 mm to 18 mm are available. Special sizes to eliminate waste and reduce jointing are available to order. TAPERED EDGE BOARDS Tapered edge boards are available with 2 or 4 sided Tapered...

Open the catalog to page 4
intoduction - 5

FERMACELL FOR WALLS AND CEILINGS FERMACELL BOARD DATA DATA, NOMINAL VALUES Dimensional tolerances at constant humidity - Board dimensions Nominal density, strength Modulus calculations (Permit No. Z-9.1-434) Characteristic strength and stiffness values of Fermaceli Gypsum Fibreboard in N/mm2 for design calculation according Perpendicular to the plane of the board Square edge Boards Specially cut sizes on request CATEGORY 1 RACKING RESISTANCE, STRENGTH AND STIFFNESS VALUES FOR EUROCODE 5 STRUCTURAL DESIGN.

Open the catalog to page 5
intoduction - 6

FERMACELL TRAINING staff are fully qualified to provide detailed technical time of your enquiry. Where special detailing or a non-standard solution is required we shall undertake to have given a preliminary answer within Visits either to your premises or site may be arranged according to your requirements. Please call us for further Fermacell's daily and continued use in thousands of high profile projects worldwide is a testament not only to the product's huge appeal and breadth of application, but also to the service and professionalism of our staff in supporting its users. Call our...

Open the catalog to page 6
intoduction - 7

PERFORMANCE CRITERIA and Wales must meet "fire resistance" performance criteria. The "reaction to fire" regulations deal with the potential contribution to a fire that basic materials may make and carry the award of a Class 0 Materials classification covering ignitability, fire propagation and surface Fermaceli Gypsum Fibreboards carry this Class 0 classification together with Euroclass A2, the second highest performance level under new EU rules of appropriately tested gypsum wallboards. Fermaceli also carries a class 1 surface spread of flame certification, the highest achievable. The...

Open the catalog to page 7
intoduction - 8

word, music and all other Sound is measured by comparing the pressure wave it creates as it travels from its source with the nominal threshold of hearing pressure and then compressing the range using a logarithmic scale. The result is the decibel scale, which starts at 0 dB - the point at which humans begin to hear sound - and progresses to 140 dB, the point at which a single short noise is likely to irreparably damage hearing. The scale enables sound levels picked up by the ear to be easily and meaningfully analysed - even a 3 dB change in sound pressure level is considered significant....

Open the catalog to page 8
intoduction - 9

houses, flats, schools, hotels and hostel types of accommodation. Whether new build or material change of use, all projects have different criteria, to improve the sound insulation and privacy between domestic and residential rooms. There are several ways of approaching compliance, primarily with the design of separating walls and floors that will meet and exceed the requirements in the guidance document. The onus is then on the installer to ensure good on site workmanship and consideration to the prevention of flanking transmission around the installed systems. As Part E sets out a...

Open the catalog to page 9
intoduction - 10

www.fermacell.co.uk THE THEORY OF SOUND INSULATION THE THEORY OF SOUND INSULATION IMPACT SOUND Airborne sound insulation is the ability of material separating two rooms to minimise the passage of airborne sound through either the dividing element or its surrounding structure. The materials are assessed on a sound reduction index by relating the sound power reduction through the material itself. Purpose built laboratories consist of two rooms with an opening between them, into which a test sample is inserted, thus allowing an evaluation of partitioning and other insulation structures....

Open the catalog to page 10
intoduction - 11

SOUND INSULATION IN DWELLINGS www.fermacell.co.uk SOUND INSULATION IN DWELLINGS SEPARATING WALLS, FLOORS AND STAIRS The airborne sound insulation standard for separating walls, floors and stairs in purpose built dwelling houses and flats is 45 dB, expressed as D T + C . This target, with the addition of C . will ensure substantial sound insulation. Floors and stairs should have maximum values of impact The figures for dwellings and flats formed by Walls in purpose built rooms for residential purposes carry a standard for airborne sound insulation of 43 dB D T + C . floors and stairs sound...

Open the catalog to page 11