Bollards
24Pages

{{requestButtons}}

Catalog excerpts

Bollards - 2

Passeig Can Feu, número 6 08205 Sabadell Barcelona

Open the catalog to page 2
Bollards - 3

Florencia Dome Champs Elysées

Open the catalog to page 3
Bollards - 5

Barcelona 80 flexible MEASURES Blendtec (Polyurethane) WEIGHT MORE COLORS OF THE RAL CHART AVAILABLE APPLUS technical description Functional description Fire resistance: CLASS E. According to standard UNE-EN-ISO 11925-2: 2002. Certified by APPLUS for use as per bollard in the street. Ability to absorb the impacts of vehicles and fully recover the verticality. Temperature resistance according to UNE-53541 standard: minimum -40º C, maximum +60º C. Impact resistance: Test of 50 impacts, bending the bollard through 90º, simulating a 1.500 kg vehicle impact at 15 Km/h. Fatigue resistance: Test...

Open the catalog to page 5
Bollards - 6

Barcelona 100 flexible MEASURES H 800 ø 100 mm stripes 30 mm H 1075 ø 100 mm stripes 75 mm MATERIAL Blendtec (Polyurethane) WEIGHT MORE COLORS OF THE RAL CHART AVAILABLE APPLUS technical description Functional description Fire resistance: CLASS E. According to standard UNE-EN-ISO 11925-2: 2002. Certified by APPLUS for use as per bollard in the street. Ability to absorb the impacts of vehicles and fully recover the verticality. Temperature resistance according to UNE-53541 standard: minimum -40º C, maximum +60º C. Impact resistance: Test of 50 impacts, bending the bollard through 90º,...

Open the catalog to page 6
Bollards - 7

Barcelona Q flexible MEASURES Blendtec (Polyurethane) WEIGHT MORE COLORS OF THE RAL CHART AVAILABLE APPLUS technical description Functional description Fire resistance: CLASS E. According to standard UNE-EN-ISO 11925-2: 2002. Certified by APPLUS for use as per bollard in the street. Ability to absorb the impacts of vehicles and fully recover the verticality. Temperature resistance according to UNE-53541 standard: minimum -40º C, maximum +60º C. Impact resistance: Test of 50 impacts, bending the bollard through 90º, simulating a 1.500 kg vehicle impact at 15 Km/h. Delivery in plasticised...

Open the catalog to page 7
Bollards - 8

Boule flexible H 800/900/1000/1200 ø 80 mm H 800/900/1200 ø 100 mm MATERIAL Blendtec (Poliuretano) WEIGHT MORE COLORS OF THE RAL CHART AVAILABLE APPLUS technical description Functional description Fire resistance: CLASS E. According to standard UNE-EN-ISO 11925-2: 2002. Certified by APPLUS for use as per bollard in the street. Ability to absorb the impacts of vehicles and fully recover the verticality. Temperature resistance according to UNE-53541 standard: minimum -40º C, maximum +60º C. Impact resistance: Test of 50 impacts, bending the bollard through 90º, simulating a 1.500 kg vehicle...

Open the catalog to page 8
Bollards - 9

Blanes flexible MEASURES Blendtec (Polyurethane) WEIGHT MORE COLORS OF THE RAL CHART AVAILABLE APPLUS technical description Functional description Fire resistance: CLASS E. According to standard UNE-EN-ISO 11925-2: 2002. Certified by APPLUS for use as per bollard in the street. Ability to absorb the impacts of vehicles and fully recover the verticality. Temperature resistance according to UNE-53541 standard: minimum -40º C, maximum +60º C. Impact resistance: Test of 50 impacts, bending the bollard through 90º, simulating a 1.500 kg vehicle impact at 15 Km/h. Delivery in plasticised...

Open the catalog to page 9
Bollards - 10

Florencia Memory form H 900/1000/1200 ø 90 mm no reflective stripes (Optional bands on request, check prices) MATERIAL Blendtec (Poliuretano) WEIGHT MORE COLORS OF THE RAL CHART AVAILABLE APPLUS technical description Functional description Fire resistance: CLASS E. According to standard UNE-EN-ISO 11925-2: 2002. Certified by APPLUS for use as per bollard in the street. Ability to absorb the impacts of vehicles and fully recover the verticality. Temperature resistance according to UNE-53541 standard: minimum -40º C, maximum +60º C. Impact resistance: Test of 50 impacts, bending the bollard...

Open the catalog to page 10
Bollards - 11

Florencia Dome flexible H 900/1000/1200 ø 100 mm no reflective stripes H 900/1200 ø 90 mm no reflective stripes (Optional bands on request, check prices) Blendtec (Polyurethane) APPLUS technical description Functional description Fire resistance: CLASS E. According to standard UNE-EN-ISO 11925-2: 2002. Certified by APPLUS for use as per bollard in the street. Ability to absorb the impacts of vehicles and fully recover the verticality. Temperature resistance according to UNE-53541 standard: minimum -40º C, maximum +60º C. Impact resistance: Test of 50 impacts, bending the bollard through...

Open the catalog to page 11
Bollards - 12

Florencia Q flexible MEASURES H 900 ø 100 mm no reflective stripes (Optional bands on request, check prices) MATERIAL Blendtec (Polyurethane) WEIGHT MORE COLORS OF THE RAL CHART AVAILABLE APPLUS technical description Functional description Fire resistance: CLASS E. According to standard UNE-EN-ISO 11925-2: 2002. Certified by APPLUS for use as per bollard in the street. Ability to absorb the impacts of vehicles and fully recover the verticality. Temperature resistance according to UNE-53541 standard: minimum -40º C, maximum +60º C. Impact resistance: Test of 50 impacts, bending the bollard...

Open the catalog to page 12
Bollards - 13

Champs Elysées flexible MEASURES Blendtec (Polyurethane) WEIGHT MORE COLORS OF THE RAL CHART AVAILABLE APPLUS technical description Functional description Fire resistance: CLASS E. According to standard UNE-EN-ISO 11925-2: 2002. Certified by APPLUS for use as per bollard in the street. Ability to absorb the impacts of vehicles and fully recover the verticality. Temperature resistance according to UNE-53541 standard: minimum -40º C, maximum +60º C. Impact resistance: Test of 50 impacts, bending the bollard through 90º, simulating a 1.500 kg vehicle impact at 15 Km/h. Delivery in plasticised...

Open the catalog to page 13
Bollards - 14

Varsovia flexible MEASURES Blendtec (Polyurethane) WEIGHT MORE COLORS OF THE RAL CHART AVAILABLE APPLUS technical description Functional description Fire resistance: CLASS E. According to standard UNE-EN-ISO 11925-2: 2002. Certified by APPLUS for use as per bollard in the street. Ability to absorb the impacts of vehicles and fully recover the verticality. Temperature resistance according to UNE-53541 standard: minimum -40º C, maximum +60º C. Impact resistance: Test of 50 impacts, bending the bollard through 90º, simulating a 1.500 kg vehicle impact at 15 Km/h. Fatigue resistance: Test of...

Open the catalog to page 14

All FCI URBAN catalogs and technical brochures

  1. Florencia

    1 Pages

  2. Mallorca

    1 Pages

  3. Berna 100

    1 Pages

  4. Formworks

    7 Pages