Technical Specifications Overview:
  • Thickness and Dimensional Tolerances: The thickness of the element should not deviate more than 0.50 mm from the nominal value. Maximum thickness variation is 0.50 mm. Width and length deviations are limited to 0.10 mm and 0.20 mm respectively. For lengths ≤ 1500 mm, the deviation should not exceed 0.5 mm.
  • Surface and Structural Characteristics: The contrast between exposed and unexposed zones should be grade ≥4 on the gray scale. The small ball diameter must withstand ≥ 15N, and the large ball diameter should be ≥ 1000 mm. Static indentation resistance is ≥ 1.25 N/mm².
  • Durability and Resistance: Surface soundness is classified as AC5 (≥ 6000 cycles). The flooring is suitable for heavy commercial (Class 33) and heavy domestic use (Class 23). It should resist staining with a force ≥ 1 kN/ml and show no visible damage from mechanical assembly or furniture legs.
  • Environmental and Safety Standards: Reaction to fire is classified as BFl s1. Formaldehyde emissions are E1 (< 3.5 mg/m² h). Antistatic charge is < 2 KV. PCP content is < 5 ppm. Emissions are classified as A+ for indoor air quality.
  • Additional Requirements: Suitable for underfloor heating with specific underlay. Moisture content at dispatch should be between 4-10%. Appearance should be free of visible defects from a distance of 1 meter.
  • Certifications: The product holds a PEFC environmental certificate (PEFC-14/35-00210) and exceeds normative values for emissions, conforming to California Section 01350 standards.
See more

Catalog excerpts

AC5 laminate flooring technical specifications-1

AC5 laminate flooring technical specifications Collections: SYNCRO, COSMOPOLITAN, TEMPO. GENERAL CHARACTERISTICS CHARACTERISTICS REQUIREMENT ∆taverage ≤ 0,50 mm to nominal value max. - tmín. ≤ 0,50 mm Length of the surface layer, l: Widht of the surface layer, w: ∆waverage ≤ 0,10 mm to nominal value w max. - wmín. ≤ 0,20 mm Straightness of the surf layer, s: Flatness of the element, f: - Width - Length Maximum individual values: W,concave≤ 0,15 % fW,convex ≤ 0,20 % f f l,concave ≤ 0,5 % l,convex ≤ 1 % Openings between elements, o: Gaps Height difference between elements, h: Dimensional variations after changes in relative humidity, δl, δw Light fastness Contrast between exposed and unexposed zone: grade ≥4 (gray scale) Static identation No visible changes. Example: <0.05 mm identation using a straight steel cylinder, Ǿ= 11.3 mm Surface soundness Abrasion resistance Impact resistance Small ball diameter >= 15N Large ball diameter >= 1000 mm CLASS 33 HEAVY COMMERCIAL USE CLASS 23 HEAVY DOMESTIC USE Locking strength for mechanically assembled pannels (Opening 0,2 mm) Effect of a castor chair No changes in appearance or damage, as defined in EN425. Using wheel d

 Open the catalog to page 1
AC5 laminate flooring technical specifications-2

ADITIONAL REQUIREMENTS CHARACTERISTICS Humidity at dispatch from the manufacturer The elements shall have a moisture content of 4 -10 % Appearance, surface defects Whitout visible effects 1m of distance CLASSIFICATION IN ACCORDING EMISSIONS - COV CHARACTERISTICS EN 16000 (French decree n° 2011-321 & arrêté of 19/04/2011) ÉMISSIONS DANS L’AIR INTÉRIEUR* Classified A+ *A+ (better) / C (worst) * Information sur le niveau d'émission de substances volatiles dans l'air intérieur, présentant un risque de toxicité par inhalation, sur une échelle de classe allant de A + (très faibles émissions) à C (fortes...