1. Catalogs
  2. Fantech
  3. TWIN GAMMA ULTRA SERIES

TWIN GAMMA ULTRA SERIES

TWIN GAMMA ULTRA SERIES

TWIN GAMMA ULTRA SERIES

Product catalog summary
Description: The Twin Gamma Ultra Series are mixed-flow roof fans designed for commercial ducted exhaust applications. They feature twin vertical discharge fans providing 100% stand-by capacity and are available in five sizes ranging from 315 to 500mm in diameter. These units are compact, low profile, and equipped with bird-mesh to prevent entry of birds and vermin.
Typical Applications: Suitable for exhausting air from commercial settings such as factories, warehouses, workshops, change rooms, retail outlets, and assembly halls.
Features: The fans are robust and lightweight, with a choice of speeds and a design suitable for vertical exhaust applications. They can be mounted at angles up to 30° and most 3-phase motors are 2-speed star/delta design. Backdraft shutters are optional but recommended to prevent short-circuiting.
Construction: The cowls are made from UV-stabilised plastic, and the impellers are mixed-flow design made from high-performance injection moulded composite material. Steel components have a corrosion-resistant finish, and bird-mesh guards are standard.
Internal Thermal Protection: All motors come with thermal protection as standard.
Testing: Airflow tests are based on ISO5801 and noise tests on ISO13347-3.
Ordering Information: Motors are external rotor, squirrel cage induction type, available in 230V single-phase and 415V three-phase, 50Hz. They are speed-controllable using electronic or auto-transformer controllers.
Suggested Specification: The roof ventilators should be of the Twin Gamma Ultra Series, providing dual fan vertical discharge with 100% stand-by capacity. Impellers should be mixed-flow design, driven by speed-controllable external rotor motors with thermal overload protection.
Ancillary Equipment: Includes speed controllers, backdraft shutters, star/delta switches, and run-on timers.
Technical Data: Detailed specifications include dimensions, nominal speed, maximum operating temperature, power consumption, and sound power levels for various models.
See more

Catalog excerpts

TWIN GAMMA ULTRA SERIES-1

TWIN GAMMA ULTRA SERIES ANCILLARY EQUIPMENT The Twin Gamma Ultra Series of Mixed-Flow roof fans have been designed for use in commercial ducted exhaust applications. Incorporating twin vertical discharge fans, the unit provides 100% stand-by capacity. These compact and low profile units are fitted with bird-mesh to prevent the entry of birds and vermin into the ducting or building. They are available in 5 sizes, extending from 315 to 500mm diameter. Typical Applications Exhaust air from a wide range of commercial applications such as factories, warehouses and workshops, change rooms, bulk goods retail outlets and assembly halls. • Robust, lightweight construction. • Choice of speeds available. • Compact, low profile design. • Designed for vertical exhaust applications. • Backdraft-shutters are an optional extra (See special note). • Can be mounted at angle up to 30°. • Most 3-phase motors are 2-speed star/delta design. Note: Pressure loss across the shutter is now included in the performance curves. Construction Cowls are UV-stabilised plastic. Impellers are Mixed-Flow design and made from high performance injection moulded composite material. Steel components have a corrosion resistant finish. Bird-mesh guards are fitted as standard. Internal Thermal Protection Thermal protection is supplied as standard on all motors Type - external rotor, squirrel cage induction motor Electricity supply - 230V, single and 415V, three-phase, 50Hz Bearings - sealed-for-life, ball Speed-controllable using electronic or auto-transformer controllers All three-phase units are fitted with 2-speed star/delta design motors See page O-2/3 for details on these motors SUGGESTED SPECIFICATION The roof ventilators shall be of the Twin Gamma Ultra Series vertical exhaust type as designed and manufactured by Fantech Pty. Ltd. They shall provide dual fan vertical discharge to provide a 100% stand-by capacity and be of the model numbers shown on the schedule/drawing. Impellers shall be made from high performance injection moulded composite material. They shall be Mixed-Flow design and driven by speed-controllable external rotor motors with integral thermal overload protection. The windband shall be of the vertical exhaust design and formed from plastic. Steel components shall be corrosion protected. All performance data shall be for a complete assembled unit based on ISO5801 for air flow and ISO13347-3 for noise. Testing Air flow tests based on ISO5801 Noise tests based on ISO13347-3 Special Note Backdraft shutters are offered as an optional extra, but are essential to prevent short circuiting and ensuring proper performance of the product. Due to this, the backdraft shutter effect on the products performance is included in the performance curves. This is to ensure accurate selections to allow reliable and predictable on-site performance. There is no longer a need to add losses due to the backdraft shutter as is required with single Gamma models. ROOF MOUNTED FANS TGU – Twin Gamma Ultra D – 3 phase E – 1 phase Fan diameter in cm Fan speed, no. of pol

 Open the catalog to page 1
TWIN GAMMA ULTRA SERIES-2

Model Approx. TGUD.. Dimensions, mm weight TECHNICAL DATA TGUD... Speed Operating AVG. dB(A) TGUE.. 1ph TGUD.. 3ph ROOF MOUNTED FANS D-37B 1 Electrical data in bold type refers to fans fitted with 2-speed star/delta motors as standard Amperages shown are a guide only, refer to our Sales Department for accurate figures at time of order.

 Open the catalog to page 2
TWIN GAMMA ULTRA SERIES-3

TWIN GAMMA ULTRA SERIES 4 pole 3 phase ROOF MOUNTED FANS

 Open the catalog to page 3

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.