Next Step in HVAC system efficiency The COMFORT CONTROL
Open the catalog to page 1Potential re Potential result otent ent • Energy efficiency - medium Energy eff • Potential n noise issues • Not adaptive to system layout changes adapt Rickard electronic VAV diffusers Energy Efficiency Meter Air Handling Unit or Fan Coil Unit with AC fans connected to a high pressure duct network that delivers air through an inefficient VAV box with a fixed geometry diffuser. Potential result Ex Example of a simpl variable simple mple geometry VAV system, y VAV Static Regain using Static Regain Duct Design t • Energy efficiency - moderate • Potential noise issues • Not adaptive to system layout...
Open the catalog to page 2Can help achieve capital savings Low Pressure Static Regain Duct Design An AirLink VAV system combines Static Regain ducting, electronic VAV diffusers and Air Handling Units/Fan Coil Units with EC fans, to achieve capital savings in almost all building types. Independent analysis that supports this has been produced based on a range of different building types in Australia. The objective of Static Regain Duct Design is to achieve the same static pressure throughout the duct run. This means the duct design must have an even static pressure from the first diffuser take off. Any duct design method...
Open the catalog to page 3Extensive range makes AirLink suitable for most building sizes MINItherm SLIMtherm Air Design Air Handling Units with Efficient EC fans Air Design Air Handling/Fan Coil Units are engineered and manufactured to the highest standard. They are fitted with highly advanced single or multiple EC plug fans that can deliver the full range of air flows with maximum efficiency. They also include dependable and high quality filters that provide integrated air filtration for most types of applications. Air Flow Range - Up to 19,000 L/s The MODUtherm “Wall of Fans” range of modular Air Handling Units feature...
Open the catalog to page 4How the system can be used in typical applications ns •Retail tenancies •Residential apartments S SLIMtherm Fan Coil Unit •University classrooms SM Series Fan Coil Unit •Retail complexes •Universities •Hospitals MINItherm Air Handling Unit •Commercial offices •Shopping centres M MODUtherm MODUtherm Air Handling Unit •Commercial offices Fantech Pty. Ltd. Victoria: New South Wales: South Australia: Northern Territory: Queensland: Western Australia: A.C.T: New Zealand: South East Asia: ntech adjustable c st e s Fantech adjustable pitch axial fan h fa a www.fantech.com.au For sales enquiries contact:...
Open the catalog to page 52 Pages
6 Pages
4 Pages
2 Pages
3 Pages
4 Pages
3 Pages
3 Pages
3 Pages
2 Pages
40 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages