Installation manual Matrix 800/400 I,II,III Matrix 1050/400 I,II,III Matrix 1300/400 I,II,III ENG
Open the catalog to page 1Installation manual MatriX 800-1050-1300/400 I,II,III *With non-combustible materials and ventilated chimney breast. * With non-combustible materials and ventilated chimney breast *With non-combustible materials and ventilated chimney breast
Open the catalog to page 2Installation manual MatriX 800-1050-1300/400 I,II,III
Open the catalog to page 3Installation manual MatriX 800-1050-1300/400 I,II,III
Open the catalog to page 4Installation manual MatriX 800-1050-1300/400 I,II,III
Open the catalog to page 5Installation manual MatriX 800-1050-1300/400 I,II,III
Open the catalog to page 6Installation manual MatriX 800-1050-1300/400 I,II,III
Open the catalog to page 7Installation manual Matrix 800-1050-1300/4001,II,III 1 Dear user Congratulations on your purchase of a Faber fire! A quality product from which you will experience warmth and atmosphere for many years. We recommend that you read this manual carefully before using the fireplace. If any problem arises despite our strict quality control, you can always contact your dealer or Glen Dimplex Benelux B.V. For any warranty claims, it is essential you first register your fireplace. During this registration, you'll find all information regarding our warranty. > Please note! The details of your...
Open the catalog to page 8Installation manual Matrix 800-1050-1300/4001,II,III 3.1 Appliance • This appliance may not be installed in a chlorine-containing environment. (Pools etc.) • This appliance must be built into an existing or new false chimney. • For transport reasons, for appliances with flexible gas pipes, the control unit (Fig. 1.3) is mounted at the bottom of the crate. Detach and mount it together with the Control box and Remote access door in as low as possible position in the false chimney. (see supplied instruction manual, 40011721). (To prevent damage to cables and pipes during transport, they are...
Open the catalog to page 9Installation manual Matrix 800-1050-1300/4001,II,III 4.1 Gas connection The gas connection must comply with the applicable local standards. > Please note! • Provide a flexible gas connection with at least 0,5m extra length, so that the control unit can be removed for installation and service! • Calculate the gas pipe so that no pressure drop occurs. We advise using a gas connection directly from the gas meter to the appliance, with a shut-off valve in the proximity of the appliance, which must always be freely accessible. Position the gas connection so that it is easily accessible for...
Open the catalog to page 10Installation manual Matrix 800-1050-1300/4001,II,III Ventilation Correct ventilation prevents damaging overheating of the gas regulator block and its electronics and also limits the temperature of the convection air. Use the supplied Faber ventilation grids or a similar alternative with a minimum free passage of 200cm2 per grid, in the space above the fire, when building the false chimney. Within the false chimney, a horizontal screen plate, made of noncombustible material, must be installed just above the ventilation openings. (see A in fig. 1.0, 1.1 or 1.2) Installation and finishing >...
Open the catalog to page 11Installation manual Matrix 800-1050-1300/4001,II,III 5.2 Side glass For cleaning only it's not necessary to remove the side glass. Matrix II and III: • Remove the front glass (chapter 5.1) • Remove the glass strip at the top (fig. 3.6 and 3.7). • Place a suction cup and remove the side glass (fig. 3.8). For replacing the glass repeat the steps in reverse order. > Please note! Avoid fingerprints on the glass; these are no longer removable once the fire is used. 6 Placing decoration material > Please note! • Place the supplied ionization cover at the burner (see fig. 4a, b and c). • Place the...
Open the catalog to page 12Installation manual Matrix 800-1050-1300/4001,II,III 7.1 Checking the flame image Let the fireplace burn for at least 20 minutes at highest setting and check the flame for: • flame distribution; • colour of the flames. If one or both points are not acceptable then check: • The position of the logs and/or the amount of chips/glass granulates. • The pipe connections for leaks. (in case of blue flames); • That the correct flue restrictor is fitted (see fig. 1.6-F); • The outlet: o Wall terminal has the correct position and side up; o Roof terminal has the correct position. • If the maximum...
Open the catalog to page 13Installation manual Matrix 800-1050-1300/4001,II,III 10 Conversion to other gas types This can only be done by replacing the burner. To do so, please contact your dealer. Always provide the type and serial number of the appliance when ordering. 11 Flue calculation A simple way to calculate whether the exhaust configuration is possible in combination with your fireplace, use the "Faber Flue App V2": This is available free of charge and can be downloaded via: Internet: Android and PC (Windows Store, (Windows 10)). App Store: iPhone, iPad and Mac. Google Play: Android smart phones and Android...
Open the catalog to page 14Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
Open the catalog to page 15Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
Open the catalog to page 16Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
Open the catalog to page 17Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
Open the catalog to page 18Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
Open the catalog to page 19Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
Open the catalog to page 20Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
Open the catalog to page 21Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
Open the catalog to page 22Installation manual Matrix 800-1050-1300/4001,II,III
Open the catalog to page 23Installation manual MatriX 800-1050-1300/400 I,II,III 13 Calculation sheet Starter length (STL) First part on top of the appliance Flue length from 0,1m till 0,45m Flue length from 0,5m till 0,90m Flue length from 1m till 1,4m Flue length from 1,5m till 2m Flue length 2m or more Roof terminal Wall terminal Total Vertical Height (TVH) measured height rounded value Total Horizontal Length (THL) Calculation Part Total Length in meters 90° Bend, vertical to horizontal 45° Bend, vertical to horizontal 90° Bend in horizontal direction 45° Bend in horizontal direction flue pipes at an angle in...
Open the catalog to page 24All Faber catalogs and technical brochures
-
e-MatriX Linear 1050-400 III
2 Pages
-
MATRIX 800-500 ST
2 Pages
-
e-MatriX Mood 800-500 RD
2 Pages
-
00-500-II e-MatriX Mood
2 Pages
-
Skive
1 Pages
-
MatriX | 1050/650 III
1 Pages
-
Faber Outdoor 2020-2021
9 Pages
-
Faber Brochure_Electric_21-22
60 Pages
-
Faber Brochure_Gas_21-22
132 Pages
-
Installation manual e-MatriX
20 Pages
-
New collection electric fires
19 Pages
-
Gas fires
51 Pages
-
Special Outdoor collection
8 Pages
-
special wood
8 Pages
-
special outdoor
8 Pages
-
faber collection 2013
86 Pages
Archived catalogs
-
SPECIAL ELECTRIC 2010
2 Pages
-
SPECIAL GAS 2010
4 Pages
-
THE BUZZ 2010
2 Pages
-
Special Electric 2009-2010
36 Pages
-
Special Gas 2009-2010
54 Pages
-
Special Wood 2009
7 Pages