Product catalog summary
Introduction
This manual provides essential information for the installation and maintenance of a Faber fireplace, which must be performed by a qualified professional. Registration is necessary for warranty purposes.
Safety Instructions
Install a protective screen if vulnerable individuals are present. Ensure the appliance is in a well-ventilated area and undergoes annual checks. Do not alter the fireplace settings or construction, and maintain a safe distance from combustible materials.
Installation Requirements
The fireplace should not be installed in chlorine-rich environments and must be built into a non-combustible false chimney. Proper ventilation is crucial, and specified Faber flue materials must be used for discharge and outlet requirements.
Gas and Electrical Connections
Gas connections must adhere to local standards, with a flexible connection for easy service access. An electrical connection requires a 230VAC/50Hz socket near the fireplace.
Preparation and Installation
Carefully remove packaging and ensure no damage to gas supply pipes. Position the fireplace correctly, considering installation requirements, and perform a functional test before constructing the false chimney.
Removing Glass
Instructions are provided for removing and replacing front and side glass panels, with caution to avoid fingerprints.
Placing Decoration Material
Specific instructions are given for placing ionization covers and inspection hatches. Avoid adding extra materials to the combustion chamber to prevent clogging.
Installation and Decoration Instructions
Place supplied pads as per guidelines. For log sets, distribute black mini chips or charcoal on the burner, avoiding double layers. Place logs and distribute black and grey chips around the burner, ensuring ignition and ionization pins remain clear. Spread glow fiber between logs for a decorative effect.
Checking the Installation
Check for gas leaks using a gas leak finder. Measure primary pressure to ensure it matches the rating plate data. Test ignition and burner using remote control and app.
Flame Image and Flue Gas Analysis
Burn the fireplace for 20 minutes at the highest setting to check flame distribution and color. Conduct a flue gas analysis using a CO/CO2 analyzer, ensuring the ratio does not exceed 1:100.
Customer Instruction and Maintenance
Advise annual checks by a qualified installer. Provide instructions on device operation, remote control, and app settings. Emphasize maintenance and cleaning of the glass, avoiding fingerprints. Conduct annual maintenance checks on the combustion chamber, burner, logs, glass, and outlet.
Conversion and Flue Calculation
Conversion to other gas types requires burner replacement by a dealer. Use the Faber Flue App V2 for flue calculations, or refer to the restrictor tables for flue lengths and restrictors.
Restrictor Tables
Tables provide guidelines for start length, vertical height, and horizontal length for different gas types and models. Ensure values fall within the restrictor table limits and adjust if necessary.
See more

Catalog excerpts

Installation manual MatriX-1

Installation manual Matrix 800/400 I,II,III Matrix 1050/400 I,II,III Matrix 1300/400 I,II,III ENG

 Open the catalog to page 1
Installation manual MatriX-2

Installation manual MatriX 800-1050-1300/400 I,II,III *With non-combustible materials and ventilated chimney breast. * With non-combustible materials and ventilated chimney breast *With non-combustible materials and ventilated chimney breast

 Open the catalog to page 2
Installation manual MatriX-3

Installation manual MatriX 800-1050-1300/400 I,II,III

 Open the catalog to page 3
Installation manual MatriX-4

Installation manual MatriX 800-1050-1300/400 I,II,III

 Open the catalog to page 4
Installation manual MatriX-5

Installation manual MatriX 800-1050-1300/400 I,II,III

 Open the catalog to page 5
Installation manual MatriX-6

Installation manual MatriX 800-1050-1300/400 I,II,III

 Open the catalog to page 6
Installation manual MatriX-7

Installation manual MatriX 800-1050-1300/400 I,II,III

 Open the catalog to page 7
Installation manual MatriX-8

Installation manual Matrix 800-1050-1300/4001,II,III 1 Dear user Congratulations on your purchase of a Faber fire! A quality product from which you will experience warmth and atmosphere for many years. We recommend that you read this manual carefully before using the fireplace. If any problem arises despite our strict quality control, you can always contact your dealer or Glen Dimplex Benelux B.V. For any warranty claims, it is essential you first register your fireplace. During this registration, you'll find all information regarding our warranty. > Please note! The details of your fireplace...

 Open the catalog to page 8
Installation manual MatriX-9

Installation manual Matrix 800-1050-1300/4001,II,III 3.1 Appliance • This appliance may not be installed in a chlorine-containing environment. (Pools etc.) • This appliance must be built into an existing or new false chimney. • For transport reasons, for appliances with flexible gas pipes, the control unit (Fig. 1.3) is mounted at the bottom of the crate. Detach and mount it together with the Control box and Remote access door in as low as possible position in the false chimney. (see supplied instruction manual, 40011721). (To prevent damage to cables and pipes during transport, they are bound...

 Open the catalog to page 9
Installation manual MatriX-10

Installation manual Matrix 800-1050-1300/4001,II,III 4.1 Gas connection The gas connection must comply with the applicable local standards. > Please note! • Provide a flexible gas connection with at least 0,5m extra length, so that the control unit can be removed for installation and service! • Calculate the gas pipe so that no pressure drop occurs. We advise using a gas connection directly from the gas meter to the appliance, with a shut-off valve in the proximity of the appliance, which must always be freely accessible. Position the gas connection so that it is easily accessible for service...

 Open the catalog to page 10
Installation manual MatriX-11

Installation manual Matrix 800-1050-1300/4001,II,III Ventilation Correct ventilation prevents damaging overheating of the gas regulator block and its electronics and also limits the temperature of the convection air. Use the supplied Faber ventilation grids or a similar alternative with a minimum free passage of 200cm2 per grid, in the space above the fire, when building the false chimney. Within the false chimney, a horizontal screen plate, made of noncombustible material, must be installed just above the ventilation openings. (see A in fig. 1.0, 1.1 or 1.2) Installation and finishing > Please...

 Open the catalog to page 11
Installation manual MatriX-12

Installation manual Matrix 800-1050-1300/4001,II,III 5.2 Side glass For cleaning only it's not necessary to remove the side glass. Matrix II and III: • Remove the front glass (chapter 5.1) • Remove the glass strip at the top (fig. 3.6 and 3.7). • Place a suction cup and remove the side glass (fig. 3.8). For replacing the glass repeat the steps in reverse order. > Please note! Avoid fingerprints on the glass; these are no longer removable once the fire is used. 6 Placing decoration material > Please note! • Place the supplied ionization cover at the burner (see fig. 4a, b and c). • Place the inspection...

 Open the catalog to page 12
Installation manual MatriX-13

Installation manual Matrix 800-1050-1300/4001,II,III 7.1 Checking the flame image Let the fireplace burn for at least 20 minutes at highest setting and check the flame for: • flame distribution; • colour of the flames. If one or both points are not acceptable then check: • The position of the logs and/or the amount of chips/glass granulates. • The pipe connections for leaks. (in case of blue flames); • That the correct flue restrictor is fitted (see fig. 1.6-F); • The outlet: o Wall terminal has the correct position and side up; o Roof terminal has the correct position. • If the maximum lengths...

 Open the catalog to page 13
Installation manual MatriX-14

Installation manual Matrix 800-1050-1300/4001,II,III 10 Conversion to other gas types This can only be done by replacing the burner. To do so, please contact your dealer. Always provide the type and serial number of the appliance when ordering. 11 Flue calculation A simple way to calculate whether the exhaust configuration is possible in combination with your fireplace, use the "Faber Flue App V2": This is available free of charge and can be downloaded via: Internet: Android and PC (Windows Store, (Windows 10)). App Store: iPhone, iPad and Mac. Google Play: Android smart phones and Android tablets....

 Open the catalog to page 14
Installation manual MatriX-15

Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)

 Open the catalog to page 15
Installation manual MatriX-16

Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)

 Open the catalog to page 16
Installation manual MatriX-17

Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)

 Open the catalog to page 17
Installation manual MatriX-18

Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)

 Open the catalog to page 18
Installation manual MatriX-19

Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)

 Open the catalog to page 19
Installation manual MatriX-20

Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)

 Open the catalog to page 20
Installation manual MatriX-21

Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)

 Open the catalog to page 21
Installation manual MatriX-22

Installation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)

 Open the catalog to page 22
Installation manual MatriX-23

Installation manual Matrix 800-1050-1300/4001,II,III

 Open the catalog to page 23
Installation manual MatriX-24

Installation manual MatriX 800-1050-1300/400 I,II,III 13 Calculation sheet Starter length (STL) First part on top of the appliance Flue length from 0,1m till 0,45m Flue length from 0,5m till 0,90m Flue length from 1m till 1,4m Flue length from 1,5m till 2m Flue length 2m or more Roof terminal Wall terminal Total Vertical Height (TVH) measured height rounded value Total Horizontal Length (THL) Calculation Part Total Length in meters 90° Bend, vertical to horizontal 45° Bend, vertical to horizontal 90° Bend in horizontal direction 45° Bend in horizontal direction flue pipes at an angle in meters...

 Open the catalog to page 24