CE Declaration of Conformity: The VIPER 400 electronic appliance by FAAC S.p.A. complies with safety directives 73/23/EEC, 93/68/EEC, 89/336/EEC, 92/31/CEE, and 93/68/EEC, declared by Managing Director A. Bassi on January 1, 2000.
Description: The VIPER 400 is an access control system managing up to 400 cards or radio codes, supporting two external readers, and featuring programmable controls for gateways and electric strikes.
Technical Specifications: It includes memory for 400 cards, connections for two readers, inputs for door status and opening, relay outputs for door control, and an alarm output. It operates on a 12v24 Vac/dc power supply and measures 113 x 90 mm.
Electrical Connections: Use shielded cables for reader connections, keeping them separate from 230V power cables, with a maximum distance of 100m.
Connection Descriptions: Terminal boards J1 and J2 connect to card readers, J3 to door status sensors and opening push-buttons, J4 and J5 are relay outputs for gateways, J6 for alarm signaling, J7 for power supply, and J8 for an external memory card.
Operating Modes: The device operates in standard, secret code setting, and programming modes, each serving different operational needs.
Programming Mode: Accessed via the PROG key, it allows configuration of card management, operational settings, time settings, output activation, and card archive import/export.
Card Management: Cards can be stored, deleted, or modified through specific sub-menus, supporting a self-learning process for card storage.
Operational Settings: Users can configure gateway management, reader types, electric strike control, and door status input logic.
Overview: The document provides instructions for configuring and managing the Viper access control system, focusing on relay outputs, reader types, electric strike management, and time settings.
1. Relay Outputs and Double Gateway Management: Relay outputs are activated for a set time upon pressing the door opening push-button, with reader A controlling entry and reader B controlling exit in double gateway management.
2. Magnetic Reader Types: Supports swipe readers and 60% insertion readers, with settings adjustable based on reader type.
3. Electric Strike Management: Monitors door status and deactivates the OUT-A relay output based on door sensor feedback to prevent unauthorized access.
4. Door Status Input: Supports NO and NC contact settings for door status sensors to prevent alarms during power-up.
5. Reader Configuration: Configurable for magnetic stripe or active card readers, with radio function activation for double gateway management.
6. Time Settings: Activation times for outputs can be adjusted from 0 to 255 seconds, with card ignore times set to prevent duplicate readings.
7. Output Activation: Outputs can be manually activated for testing or configuration, with remaining activation time displayed.
8. Card Archive Import/Export: Card and radio code data can be exported or imported for backup or updates, excluding configuration data.
9. Total Reset: Restores default settings and deletes the card archive through a specific key sequence during power-up.
10. Software Version: Displayed briefly at power-up.
11. Typical Installations: Includes double vehicle passageways and pedestrian gateways, both manual and automated.
See more

Catalog excerpts

VIPER 400-1

VIPER 400 These instructions apply to the following model: VIPER 400 electronic appliance LAY-OUT OF VIPER CARD DIS CE DECLARATION OF CONFORMITY Manufacturer: FAAC S.p.A. Address: Via Benini, 1 - 40069 Zola Predosa BOLOGNA - ITALIA - Declares that: The Viper 400 electronic appliance conforms to the essential safety requirements of the following directives: 73/23/EEC and subsequent amendment 93/68/EEC. 89/336/EEC and subsequent amendment 92/31/CEE and 93/68/EEC Additional information: These products underwent tests in a typical, uniform configuration (all products manufactured by FAAC S.p.A.). The Managing Director A. Bassi TABLE 1 VIPER CARD COMPONENTS Introduction: meanings of the following terms as used in these instructions: gateway->the transit area door -> the structure located at the gateway (door, barrier, gate,…) whether automated or not card -> magnetic card or transponder supplied with a code, which is read by an appropriate reader, or a radiocontrol code which is controlled just like a card by means of the connected radio receiver and radio interface. Viper is used for simple control of access, combined with one or more card readers. The card is able to control: • 1 single gateway at entry/exit • 2 separate gateways (one at entry and the other at exit) Only cards and radio codes input in the archive at programming are recognised. TECHNICAL SPECIFICATIONS POWER •Memory capable of recognising a maximum of 400 cards or radio codes •Facility for connecting directly two external readers •Settable control of 1 gateway / 2 gateways •Settable control of electric strike •Settable control of remote control codes •3 displays with 7-segment LEDs for viewing card number and for programming •5 micro-pushbuttons for programming •Inputs: 2 for external readers (Reader A – Reader B) 1 for “door status” microswitch (NO/NC) 1 for door opening push-button (NO) •Outputs: 2 with relay (door-opening Reader A – door-opening Reader B) 1 open-collector (alarm siren) •Power supply: 12Ö24 Vac/dc •Dimensions: 113 x 90 mm •Optional external memory card for archive import/export •Optional external mixer card for connecting two readers to the same Viper input •Optional external radio interface card for managing remote control codes Fuse F1 5x20 400mA/250V delayed LED display Programming micro-pushbuttons A-Reader terminal board (IN-A) B-Reader terminal board (IN-B) Inputs terminal board (INPUT) A-relay output terminal board (OUT-A) B-relay output terminal board (OUT-B) Alarm output terminal board for open collector (ALARM) Power supply terminal board 12V 24Vac/dc (POWER) Connector for external memory card (EXT MEM) To avoid induced noise, separate the card connection cables from any 230V~ power cables and use separate sheaths. To connect the readers (max distance 100m), use a 5x0.5 shielded cable, connecting the shield to the power negative (

 Open the catalog to page 1
VIPER 400-2

Data are exported to the external memory in order to have a back-up copy or to copy the archive on another Viper (see programming menu #5). Magnetic or passive card readers equipped with a Magnetic Stripe output can be connected indiscriminately. The terminal boards are designed to accept connection of an optional mixer card (to double the readers that can be connected to the input), a radio interface (to manage radiocontrols) and, subject to appropriate programming, FAAC active readers. 4. OPERATING MODES Viper can function in one of the following operating modes: •Standard operating mode •Secret...

 Open the catalog to page 2
VIPER 400-3

ENGLISH MENU O Column "D" indicates default settings > Procedure for inputting the secret code (if the function was activated): • ''_00‘ is shown; set the 1st secret code number, using ^or^and press OK; • ''_00‘ is shown; set the 2nd secret code number, using ^or^and press OK; • ''_00‘ is shown; set the 3rd secret code number, using ^or^and press OK; If the input code is correct, "_/_" is shown indicating that you have accessed the programming mode, otherwise you return to standard operating mode. > When "_ t_" is shown, Viper is in programming mode and suggests the first of a set of menus. Available...

 Open the catalog to page 3
VIPER 400-4

Ģ Use keys éandê to cycle-scan occupied locations only (hold down one or the other to increase scanning speed). The associated location is shown for each location, through the 7 status of the two A and B LEDs in fig.4 (see function “2_7”). Ģ When you have chosen the location, press the CANC key, and the following sequence is shown cyclically: -A only lighted, B only lighted, A+B off, A+B lighted. Ģ Press the OK key to confirm and go on to the next location or press PROG to confirm and return to menu selection. Press éorê not to confirm and go on to the next location. OPERATIONAL SETTINGS To change...

 Open the catalog to page 4
VIPER 400-5

To change the setting , use and then press OK (to exit without modifying, press the PROG key). Radio function disabled: Viper performs in the standard manner described in "S_1" Radio function activated: This function is effective only for double gateway management and is intended for use with FAAC model SLP self-learning radiocontrol. The specific radio interface connected to an input (either IN-A or IN-B will do) must be used to convert radio codes into Magnetic Stripe outputs (Viper is able to recognise these). In double gateways, a valid card will of course activate the relay output corresponding...

 Open the catalog to page 5
VIPER 400-6

ENGLISH Ģ “__0” steady is shown on the right-hand display. __0 __ Ģ To select the setting use éorê and then press OK. Available associations : 0 “__0” steady = to exit without executing reset (default) “__1” flashing = to execute reset 1 To exit without confirming, press PROG . OUT-B OUTPUT ACTIVATION Ģ Select sub-menu “4_2” and press OK . The OUT-B output is activated for the same time as for a valid card. Ģ The remaining time is shown during activation. To finish activation and exit before the entire time has elapsed, press key PROG or OK ALARM OUTPUT ACTIVATION Ģ Select sub-menu “4_3” and...

 Open the catalog to page 6

Archived catalogs

  1. B614

    4  Pages

  2. TAG - 10

    2  Pages

  3. S800 ENC

    4  Pages

  4. S800H ENC

    4  Pages

  5. 620

    2  Pages

  6. TK20

    6  Pages

  7. S450H

    2  Pages

  8. C720

    2  Pages

  9. A1400 AIR

    8  Pages

  10. 750 operator

    2  Pages

  11. 640

    2  Pages

  12. 746

    2  Pages

  13. S418

    4  Pages

  14. BOLLARDS

    8  Pages

  15. S700 operator

    9  Pages

  16. 740 - 741

    2  Pages

  17. XT 868 (new)

    2  Pages

  18. T- Mode

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.