Overview: FP McCann is a leading UK manufacturer of precast concrete solutions, offering a wide range of products including drainage and water management systems, tunnel and shaft solutions, and more. Their modern manufacturing plants are strategically located across the UK and Ireland, ensuring high-quality production and efficient delivery.
Box Culverts: FP McCann's box culverts are designed and manufactured to meet current design specifications and standards. They are available in various sizes, with spans from 1000mm to 5400mm and heights from 500mm to 3600mm. A bespoke CAD design service is available for non-standard sizes and features.
Benefits: Box culverts offer ease of installation, structural strength, long life performance, and minimal maintenance. They can be customized with features like dry weather flow channels, mammal ledges, and dual cell configurations.
Applications: Box culverts are used in various civil engineering projects, including attenuation and storage tanks, watercourse diversion, road crossings, pedestrian and vehicle subways, and more.
Installation Guidelines: Installation and jointing details are available in the Box Culvert Association's "Guide to Site Practice." Design criteria should include internal span, height, number of runs, fill depth, usage, and surface loading conditions.
Technical Specifications: The document provides detailed internal dimensions and discharge rates for different culvert sizes, calculated using the Colebrooke White formula under specific conditions.
Contact Information: For sales and technical inquiries, contact FP McCann at 01335 361269 or visit their website at fpmccann.co.uk/box-culverts.
See more

Catalog excerpts

Box Culvert-1

Precast Concrete Solutions. drainage & water management box culverts brochure

 Open the catalog to page 1
Box Culvert-2

FP McCann is the UK’s market leader in the manufacture, supply and delivery of precast concrete solutions. Our comprehensive precast concrete business extends to include: Drainage & Water Management Tunnel and Shaft Solutions Rail Power & Infrastructure Solutions Walling Solutions Fencing Solutions Agricultural Solutions Flooring Solutions Bespoke specialist precast product service Modern manufacturing plants at Alnwick (Northumberland), Cadeby (Warwickshire), Ellistown (Leicestershire), Grantham (Lincolnshire), Knockloughrim (Northern Ireland), Littleport (Cambridgeshire), Lydney (Gloucestershire),...

 Open the catalog to page 2
Box Culvert-3

benefits of box culverts Designed and manufactured in accordance with all current design specifications and relevant standards, FP McCann box culverts are available in span sizes from 1000mm to 5400mm and internal heights from 500mm to 3600mm dependant on the final mould configuration adopted. A bespoke CAD design service is also available where non-standard unit sizes can be accommodated along with any other internal features requested by the client. FP McCann’s experienced engineers and detailing team together with a modern production facility at Telford, Shropshire, have the flexibility to...

 Open the catalog to page 3
Box Culvert-4

Typical Culvert Units are available in internal span sizes from 1000mm to 5400mm and internal heights from 500mm to 3600mm, with unit lengths to a maximum of 2000mm dependant on final mould configuration (please refer to internal dimensions chart). Half round (or equivalent) channels can be cast into the floor of the units at any position with a choice of equivalent half round diameters. Combined with either a channel or cast as a “vee” benching improves self cleansing flow rates

 Open the catalog to page 4
Box Culvert-5

Sales & technical enquiries 01335 361269 fpmccann.co.uk/box-culverts Mammal Ledges Cast in mammal ledges allow access through the culvert to wildlife without the requirement for extra site provisions Dual Cell Used to facilitate separate water passage through the structure. Bespoke units accommodating a variety of features can be manufactured to the customers design requirements - a few examples can be seen on the right. Access opening Side pipe entry Integral or bolt on end wall

 Open the catalog to page 5
Box Culvert-6

Installation Guidelines For installation and jointing details, refer to the Box Culvert Association’s “Guide to Site Practice” which can be downloaded from the BCA’s website, www.boxculvert.org.uk Internal Dimensions (Based on flat invert culvert units) Key: Flow area m2 / Discharge rate m3/sec Design Criteria Design loading criteria is generally specified by the scheme engineer and ideally should include as a minimum the information below: Exposure conditions should be specified and where available, design codes provided. Further design requirements may include for inlet/outlet points, access...

 Open the catalog to page 6
Box Culvert-7

Sales & technical enquiries 01335 361269 fpmccann.co.uk/box-culverts Please note These figures are a guide only and will be dependant on the mould configuration used in manufacture. Discharge rates are calculated using Colebrooke White formula for a fully wetted perimeter under uniform flow conditions and assuming a flat invert culvert unit. The assumed laying gradient (s) is 1:1000 with a roughness co-efficient (k) of 0.3. Where different values maybe required please contact the office number above to discuss your specific requirements. Width mm (internal span) 2400

 Open the catalog to page 7
Box Culvert-8

Weston Underwood Office: Bullhurst Lane, Weston Underwood, Derbyshire, DE6 4PH. Tel: 01335 361269 Fax: 01335 361410

 Open the catalog to page 8