1. Catalogs
  2. Expansion Electronic
  3. NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)

NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)

NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)
1 / 14 PagesView full catalog

NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)

Product catalog summary
Introduction
The document discusses new technologies for improving Indoor Air Quality (IAQ) through the use of UC (Universal Cleaner) systems. These systems are designed to efficiently remove pollutants and odors, regenerate ionic equilibrium, and transform work and leisure environments into areas of well-being.
Specifications
The UC systems are capable of reducing bacterial levels by 88% and PM10 particles by 98.95%. They operate at a maximum noise level of 61 dB and comply with the VDI 6022 standard, achieving a 90% pollutant reduction within the first 10 minutes.
Advantages of UC Installation
  • High level of well-being and optimal indoor air hygiene
  • Negligible noise level
  • Easy and quick installation
  • Low power consumption and energy efficiency
  • Easy maintenance and excellent reliability
  • Increased personnel concentration and productivity
Functionality
The UC systems improve IAQ by filtering micro particles (PM10), reducing airborne microorganisms, minimizing odors, controlling CO2 levels, and restoring the natural balance of ions.
Reasons for Installation
  • Efficient filtration of micro particles and fumes
  • Improvement of indoor air quality even when outdoor air is polluted
  • Reduction of indoor background smells
  • Prevention of airborne transmission of diseases
  • Ensuring hygiene
Configurations and Performance
The document lists various UC models (UC12, UC13, UC122, UC123, etc.) with different volumetric coverage and IAQ levels. Each model is evaluated based on its performance with and without smokers present, with ratings ranging from insufficient to excellent.
Technical Data
Each model's performance is detailed in terms of air quantity (recycling and external), noise levels, pollutant efficiency (EN 779), and antibacterial efficiency. The emission of negative ions and odor elimination capabilities are also specified.
Conclusion
The UC systems offer a comprehensive solution for enhancing indoor air quality, providing significant health and productivity benefits while maintaining energy efficiency and ease of use.
See more

Catalog excerpts

NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)-1

§IAQf NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q) > For the removal of pollutants and smells with elevated efficiency > To regenerate the ionic equilibrium > To turn sites of work and leisure into a real oasis of well-being www.expansion-electronic.com BKPRNSION ELECTROniC

 Open the catalog to page 1
NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)-2

What are the advantages by installing the UC ? > high level of well-being > optimal indoor air hygiene > negligible noise level (dBA) > easy and quick installation > very low power consumption > consistent energetic advantages (less heating and cooling) > easy maintenance > excellent reliability > increased personnel concentration and productivity In what way does the UC produce IAQ ? > through optimal filtering of micro particles (PM10) and air suspended fumes > through efficient reduction of air suspended micro organisms (bacteria, yeast, mould) > through significant reduction of smells > through...

 Open the catalog to page 2
NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)-3

Why install the UC ? > to efficiently and rapidly filter out micro particles and fumes ranglng 0,1 -10 ym (PM10) > to breathe clean air also when the outside air is polluted > to dramatically improve the degree of wetl-being normally prsent in indoor areas > to reduce the typical indoor background smells 151 > to stop the aeriat transmission of contagious diseases (colds, flue etc) > to guarantee the hygine IAQ: > 24 configurations available > can be fitted in any modular ceiling System of 600 x 600 > capacity 1460 m3/h * 290 m3/h externat air > IAQ/price ratio = excellent *- scientific air quality...

 Open the catalog to page 3
NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)-4

9 85 ■■s'vAv.expansion-eiec:roniC.coTi EVtPtlHSlQH ELECIRODIC

 Open the catalog to page 4
NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)-5

www.expansion-electronic.com BKPRNSION ELECTROniC

 Open the catalog to page 5
NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)-6

O v O O O 0 0 0 o O w o 0 0 0 o o o 0 0 0 0 0 0 o o o 0 0 0 o O KJ o o o 0 0 0 o o o 0 0 0 0 0 0 o o o 0 0 0 o o o OOu 0 0 0 o o o 0 0 0 o n O O O O o 0 0 0 o ^ 0 0 0 o o o 0 0 0 o o o 0 0 0 Mi "> _ p a = * <% » a> o Õ4' = Eco C Q. o LU Dכ _l _l LU Q < _l LU > LU _l o < LL O O0.2 Oq t=.±> Q"D ...0 ^ZSOOQX ._CO(T3 O>CD I I I I I I I I I I I I o co w  Օ w Օ Օ Օ w Օ CD CN Օ « Օ Օ o co o CN o o co o co CD CN Q Z LU O LU _I O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 COCOCNCNt-t-t-t-LOLOCNCNOOOOCOCO E E 3 O > X ro E O O O O 0 0 0 o o o o o o o 0 0 0 o o o 0 0 0 o o o 0 0 0 o o o 0 0 0 o o o 0 0...

 Open the catalog to page 6
NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)-7

MODULAR AIR CLEANERS SERIES UC Mod: UC12 (only cleaning) with remote control Model UC12 1° Speed 3° Speed Air quantity (recycling) Air quantity (introduced from external) Noise level 660 m3/h no 44 dB 98,95% 92,00% 88,00% yes yes 98,95% 92,00% 55,00% no no 97,40% 91,00% 30,00% no no 1040 m3/h no 54 dB 97,80% 87,25% 82,00% yes yes 97,80% 87,25% 50,00% no no 96,60% 86,50% 25,00% no no 1261 m3/ no 58,5 dB 97,20% 85,00% 78,50% yes yes 97,20% 85,00% 45,00% no no 95,80% 83,50% 20,00% no no Nature System Efficiency (EN779) Efficiency (EN779) Efficiency Emission of ngative ions Odor limination AFC Efficiency...

 Open the catalog to page 7
NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)-8

MODULAR AIR CLEANERS SERIES UC min 0,6m / max 4,8m ai eu -CE 03- Mod: UC12s (only cleaning) _|4-----4_ -4J.-----i|_ with remote control Model UC12s 1° Speed 2° Speed peed Air quantity (recycling) Air quantity (introduced from external) Noise level 494 m3/h no 44 dB 99,15% 91,00% 88,00% yes yes 99,15% 91,00% 55,00% no no 97,60% 90,00% 30,00% no no 782 m3/h no 53,5 dB 98,70% 86,00% 82,00% yes yes 98,70% 86,00% 50,00% no no 97,50% 85,25% 25,00% no no 982 m3/h no 58 dB 97,80% 82,00% 78,50% yes yes 97,80% 82,00% 45,00% no no 96,40% 80,50% 20,00% no no Nature System Efficiency (EN779) Efficiency (EN779)...

 Open the catalog to page 8
NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)-9

MODULAR AIR CLEANERS SERIES UC «r Mod: UC13 (cleaning plus introduced external air) - חi\- r -14-----il- -----il- with remote control Model UC13 1° Speed 2°Spe ed 3° S peed Air quantity (recycling) Air quantity (introduced from external) Noise level 660 m3/h 100 m3/h 47 dB 98,95% 92,00% 88,00% yes yes 98,95% 92,00% 55,00% no no 97,40% 91,00% 30,00% no no 1040 m3/h 180 m3/h 57 dB 97,80% 87,25% 82,00% yes yes 97,80% 87,25% 50,00% no no 96,60% 86,50% 25,00% no no 1261 m3/h 270 m3/h 61,5 dB 97,20% 85,00% 78,50% yes yes 97,20% 85,00% 45,00% no no 95,80% 83,50% 20,00% no no Nature System Efficiency...

 Open the catalog to page 9
NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)-10

MODULAR AIR CLEANERS SERIES UC Mod: UC13S (cleaning plus introduced external air) -46------i\- -44-----#- -44------41- with remote control Model UC13s 1° Speed 2° Speed peed Air quantity (recycling) Air quantity (introduced from external) Noise level 500 m3/h 100 m3/h 47 dB 99,15% 92,25% 88,00% yes yes 99,15% 92,25% 55,00% no no 97,60% 91,20% 30,00% no no 780 m3/h 180 m3/h 56,5 dB 98,20% 87,80% 82,00% yes yes 98,20% 87,80% 50,00% no no 96,90% 86,80% 25,00% no no 1000 m3/h 270 m3/h 61 dB Nature System Efficiency (EN779) Efficiency (EN779) Efficiency Emission of ngative ions Odor limination AFC...

 Open the catalog to page 10
NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)-11

MODULAR AIR CLEANERS SERIES UC ETJ �9999999999999999� Mod: UC122 (only cleaning) with remote control Model UC122 1° Speed peed Air quantity (recycling) Air quantity (introduced from external) Noise level 820 m3/h no 44 dB 98,15% 85,00% 88,00% yes yes 98,15% 85,00% 55,00% no no 96,60% 84,00% 30,00% no no 1260 m3/h no 53 dB 97,20% 78,50% 82,00% yes yes 97,20% 78,50% 50,00% no no 96,00% 77,40% 25,00% no no 1450 m3/h no 58 dB 96,75% 75,00% 78,50% yes yes 96,75% 75,00% 45,00% no no 95,30% 73,50% 20,00% no no Nature System Efficiency (EN779) Efficiency (EN779) Efficiency Emission of ngative ions Odor...

 Open the catalog to page 11
NEW TECHNOLOGIES FOR INDOOR AIR HYGIENE AND QUALITY (I.A.Q)-12

MODULAR AIR CLEANERS SERIES UC Mod: UC122S (only cleaning) ( -44------11- -14-----#- -44------41- r with remote control 1° Speed 3° Speed Air quantity (recycling) Air quantity (introduced from external) Noise level 698 m3/h no 44 dB 98,85% 87,00% 88,00% yes yes 98,85% 87,00% 55,00% no no 97,30% 86,00% 30,00% no no 1078 m3/h no 53 dB 97,52% 81,00% 82,00% yes yes 97,52% 81,00% 50,00% no no 96,30% 95,50% 25,00% no no 1289 m3/h no 58 dB 97,20% 78,50% 78,50% yes yes 97,20% 78,50% 45,00% no no Nature System Efficiency (EN779) Efficiency (EN779) Efficiency Emission of ngative ions Odor limination AFC...

 Open the catalog to page 12

All Expansion Electronic catalogs and technical brochures

  1. Serie c

    8  Pages

  2. Carbox

    2  Pages

  3. FI SYSTEM

    2  Pages

  4. FX SYSTEM

    2  Pages

  5. UC1200

    12  Pages

  6. IONIZER

    2  Pages

  7. ECOLIGHT

    8  Pages

  8. FEM - FEL

    2  Pages

  9. UC 800

    2  Pages

  10. PROLIFE

    2  Pages

  11. REOCLEAN

    2  Pages

  12. UC SERIES

    8  Pages

  13. ISO 16890

    12  Pages

  14. FE

    8  Pages

  15. FEL

    4  Pages

  16. UC 400-600

    2  Pages

  17. UCO SERIES

    2  Pages

  18. UC Series

    14  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.