12M
2Pages

{{requestButtons}}

Catalog excerpts

12M - 1

# EUROSTER e12M Designed for control of heating zone with a 3 or 4-way valve Controlled device Supply voltage Maximum load of the outputs Maximum power consumption of the receiver Temperature measurement range Temperature control range Temperature control accuracy Temperature reading accuracy Hysteresis range Visual signalization Operating temperature Storage temperature Ingress protection rating Color Installation method Controller weight (without packaging) Standards, approvals, certificates Warranty period Dimensions (W/H/D) mm Content of the controller set ■ control of 3-point actuator of a mixing valve ■ control of CH zone pump ■ weather-based setting of heating zone preset temperature ■ hourly schedule of heating zone operation ■ cooperation with room thermostat ■ automatic switching on and off of the heating according to the outdoor temperature ■ function of temporary switching on of zone with a preset temperature (floor preheating, fast heating up of rooms) ■ zone overheating protection, frost protection ■ alarm indication ■ option of manual switching on of the outputs ■ Anti-Stop function - protection of pumps against seizure ■ legible, graphical, backlit LCD ■ set of temperature sensors included 3-point actuator of mixing valve, CH pump 230 V 50 Hz 1 A 230 V 50 Hz 3 W 0°C...+100°C +10°C...+90°C rc rc 2°C - 10°C backlit LCD +5°C...+45°C 0°C...+45°C IP40 black wall-mounted 920 g conformity with LVD, EMC, and RoHS 2 years 150/90/52 Euroster 12M controller with temperature sensors, screw anchors User Manual with Warranty Certificate, mounting template, sensor hose clips P.H.P.U. AS, Chumi§tki 4, 63-840 Krobia, Poland / euroster@euroster.

Open the catalog to page 1
12M - 2

Length of cables: 1. Controller power cable: 1.5 m 2. CH pump power cable: 1.5 m 3. Valve actuator power cable: 3 m 4. Connection of a room thermostat: 0.5 m The following diagrams are simplified and do not cover all the elements necessary for the correct operation of the system. MOUNTING TEMPLATE Sample diagram of control system. or o cr 1. Outdoor temperature sensor 2. Room thermostat 3. Heating zone temperature sensor 4. CH zone pump 5. Mixing valve with actuator 6. Feeding temperature sensor www.euroster.pl P.H.P.U. AS, Chumietki 4, 63-840 Krobia, Poland / euroster@euroster.com.pl

Open the catalog to page 2

All EUROSTER catalogs and technical brochures

  1. Q8TXRXM

    2 Pages

  2. T6

    2 Pages

  3. T6RX

    2 Pages

  4. EUNI3

    2 Pages

  5. EWSRX

    2 Pages

  6. 11WB

    2 Pages

  7. CG2

    2 Pages

  8. Q7TXRX

    2 Pages

  9. Q1TXRX

    2 Pages

  10. Euroster CG2

    2 Pages

  11. Euroster 813

    2 Pages

  12. Euroster 506

    2 Pages

  13. Euroster 11Z

    2 Pages

  14. Euroster 11W

    2 Pages

  15. Euroster 11M

    2 Pages

  16. Euroster 11K

    2 Pages

  17. Euroster 11E

    2 Pages

  18. Euroster 11C

    2 Pages

  19. Euroster 11B

    2 Pages

  20. EQ7

    2 Pages

  21. E2006TXRX

    2 Pages

  22. Eurostar 11

    2 Pages

  23. Controllers

    2 Pages