Description: The document describes an
insulation board with a core of rigid polyurethane (PIR) foam, covered with 50µm aluminium foil on both sides. It is used for
thermal insulation in buildings, specifically for warm flat roofs under membrane waterproofing systems.
Physical Features: The board is available in various thicknesses (40, 50, 60, 80, 100 mm) with a standard width of 1200 mm and lengths of 2500 mm for road shipments and 2225 mm for sea shipments. The weight varies with thickness, ranging from 1.28 kg/m² to 3.20 kg/m².
Technical Features: Key technical specifications include:
- Width and length tolerances are ±7.5 mm and ±10 mm, respectively.
- Thickness tolerance varies by thickness, with specific values for each.
- Thermal conductivity is 0.023 W/m*K, and thermal resistance varies with thickness.
- Dimensional stability is specified under certain conditions of temperature and humidity.
- Compressive stress is ≥ 120 kPa, and tensile strength is ≥ 100 kPa.
- Water absorption is ≤ 2%, and water vapour resistance is 20 hm²Pa/mg.
- Reaction to fire is classified as B-s2,d0 for thickness ≤ 80 mm and B-s3,d0 for thickness > 80 mm.
- Release of dangerous substances (TVOC) is < 1000 µg/m³, rated A+.
Properties: The insulation board features closed cell foam, is free from FCF/HCFC, does not melt or drop, and has great internal cohesion, preventing delamination.
For further information, contact the Technical Department at
[email protected] or by phone. EUROPERFIL, S.A. reserves the right to change the document without notice.