video corpo

SIF

SIF
1 / 10 PagesView full catalog

SIF

Product catalog summary
Applications: The fan is designed for use in multiple arm systems, modular extraction hood systems, and push-pull systems.
Specifications:
  • Physical Properties: The fan and housing are made of steel, with aluminium profiles and corners. The motor design is IEC 132 (WEG), with a discharge position of RD 0 and a radial fan type. Design conditions are set at 20°C (68°F) at sea level.
  • Performance: The fan operates at 2850 rpm. Noise levels are measured according to ISO 3746, with a noise reduction of approximately 10 dB(A) when using a sound-absorbing case.
  • Electrical Data: Connection voltage is 400-690V/3ph/50Hz, with a maximum of 20 start/stops per hour. It has an insulation class F with PTC and protection class IP 55.
  • Ambient Conditions: Operating temperatures range from 5°C to 60°C, with a maximum relative humidity of 80%. Storage conditions are similar.
  • Options and Accessories: Includes mounting frames, silencers, and an outdoor kit for rain resistance.
Scope of Supply: The package includes an extraction fan in a sound-absorbing case, a key, and strain relief.
Order Information: The product is available in various models (SIF-700 to SIF-2000) with specific article numbers for each configuration.
Shipping Data: The harmonized tariff code is 8414.5940.90, and the country of origin is the Netherlands.
Approvals/Certificates: The fan complies with Directive 2011/65/EC (RoHS).
Fan Curves: Detailed fan curves are provided for each model, indicating performance metrics such as air volume and pressure.
See more

Catalog excerpts

SIF-1

SIF RANGE SIF-700/900/1200/1500/1800/1900/2000 LI/RI Extraction fan with straight blades to be used in central welding fume extraction systems or general filtration systems. It is mounted in a sound absorbing case with inspection cover either left (“LI” type) or right (“RI” type). The fan is equipped with flexible inlet and outlet adapters and placed on shock absorbers. In case it is combined with a central filter unit, the fan has to be connected to the outlet side of the filter unit. product data sheet APPLICATIONS The fan is intended to be used in the following configurations: ––multiple arm systems ––modular extraction hood systems ––push-pull systems SPECIFICATIONS Physical properties Material: • fan • housing Options and accessories Mounting frame refer to table on page 3 Silencer (straight or elbow refer to table on page 3 90°) SIF outdoor; fans suitable for outdoor installation (rainresistant) Outdoor kit consists of: • rain cover over sound absorbing case, including coupler for duct or silencer • ventilation grids provided with rain cover • seams of the absorbing case being fully sealed (except for the inspection cover) SIF outdoor • -20°C (-4°F) • 20°C (68°F) • 60°C (140°F) • steel • steel with aluminium profiles and corners Motor design Discharge position Design conditions Extraction fan in sound absorbing case - Key - Strain relief Noise level according to ISO 3746 (fan without sound absorbing case) refer to attached fan curves Noise reduction sound absorbing case Scope of supply Order information Number/package Electrical data Harmonized Tariff Code Connection voltage Insulation class Protection class Directive 2011/65/EC (RoHS) valid as of 8 June 2011 Storage conditions Ambient conditions

 Open the catalog to page 1
SIF-2

FAN CURVES (QUICK REFERENCE GUIDE) Detailed fan curves: refer to attachments Selection FAN LI/RI INSPECTION COVER LI = inspection cover left Remaining specifications: refer to table on next page. RI = inspection cover right

 Open the catalog to page 2
SIF-3

Table: remaining specifications SIF-900 Electrical data Nominal current Mounting frame Refer to selection table below Silencer (straight or elbow 90°) Available options Dimensions (ref. image below) and weight Order information Article number: • SIF/LI • SIF/RI • SIF/LI outdoor • SIF/RI outdoor Gross weight (incl. pallet) Shipping data Dimensions (ref. table above) SELECTION TABLE: FAN MOUNTING FRAMES Fan type Filter system **) Mounting frame*) The frame height is based on MDB units with a vertical outlet. This concerns configurations consisting of filter modules MBD-BM/2 and MDB-BM/4. Filter...

 Open the catalog to page 3
SIF-4

Temperature = 20°C (68°F) − Density = 1,024 kg/m3 (0.064 lbs/ft3)− Total pressure

 Open the catalog to page 4
SIF-5

Temperature = 20°C (68°F) − Density = 1,024 kg/m3 (0.064 lbs/ft3)− Total pressure 2 Lpa = sound level in dB(A) at 1.5 m (5 ft) distance (free field)

 Open the catalog to page 5
SIF-6

0.45 kgm² 0.48 kgm² 0.54 kgm² Temperature = 20°C (68°F) − Density = 1,024 kg/m3 (0.064 lbs/ft3)− Total pressure 2 Lpa = sound level in dB(A) at 1.5 m (5 ft) distance (free field)

 Open the catalog to page 6
SIF-7

7 Lpa = sound level in dB(A) at 1.5 m (5 ft) distance (free field) Temperature = 20°C (68°F) − Density = 1,024 kg/m3 (0.064 lbs/ft3)− Total pressure

 Open the catalog to page 7
SIF-8

Volume/pressure curve Volume/power curve Volume [m³/h] Volume tolerance ± 5% Motor curve

 Open the catalog to page 8
SIF-9

Volume/pressure curve Volume/power curve Volume [m³/h] Volume tolerance ± 5% Motor curve

 Open the catalog to page 9
SIF-10

Lpa = sound level in dB(A) at 1.5 m (5 ft) distance (free field) Temperature = 20°C (68°F) − Density = 1,024 kg/m3 (0.064 lbs/ft3)− Total pressure

 Open the catalog to page 10

All Euromate catalogs and technical brochures

  1. SparkShield

    4  Pages

  2. OilShield

    8  Pages

  3. DraftMax

    4  Pages

  4. FlexHood

    4  Pages

  5. Extraction arms

    12  Pages

  6. FAN-42

    2  Pages

  7. MNF

    2  Pages

  8. FUA

    4  Pages

  9. FAN-28

    2  Pages

  10. Smoking table

    2  Pages

  11. Ashtray

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.