video corpo

IB850

IB850

IB850

Product catalog summary
Gas Specifications:
- Heat output: 9.0kW
- Gas Input: 42MJ/h
- Gas Connection: Front right-hand corner of heater
- Electrical Connection: 240V 3 Pin plug within 1.2m of the rear left-hand corner of heater
Flueing the Heater:
The heater requires a conventional flue with a 100mm diameter flue system, compliant with NZS 5261 / AS5601 / AG601-2000 standards. A power flue system is also available.
Creating the Cavity:
The cavity must be dimensioned according to the provided drawings. The wall board can be standard dry wall. Install the flue and Zero Clearance Kit (ZCK) first, followed by power and gas services, to facilitate easy installation of the fire once the room is complete.
Order of Installation:
1. Create cavity and install flue
2. Fit ZCK and install gas & power services
3. Install and commission the gas fireplace after room completion
Ventilation:
Additional ventilation is required as per Clause G4.2.0 of the New Zealand Building Code and Section 2.6.6 of the New Zealand Gas Installation Standard for open flued natural draught appliances.
Mantle Clearance:
Mantles or ledges made from combustible materials must adhere to specified dimensions. Ensure a 30mm clearance around the fascia for removal ease.
Hearth Requirements:
A non-combustible hearth must extend at least 300mm from the fire front if installed at floor level. For heat-sensitive floor coverings, extend the hearth to 450mm.
Raising the Fire:
No hearth is required if the fire base is more than 100mm off the ground. A four-sided fascia is recommended.
Corner Installations:
Minimum interior wall size and flue position are specified for corner installations.
Electrical Equipment Clearance:
Recommended clearances for electrical equipment above the gas fire are provided, with options for shelf or recessed mounting.
See more

Catalog excerpts

IB850-1

IB850 Gas Fire Information sheet for builders and architects. Creating the Cavity: The dimensioned drawings below show the product dimensions and minimum size of the opening that must be created. The wall board that lines the outside of this opening can be normal dry wall (Gib Board) and does not need to be non-combustible. The flue and Zero Clearance Kit (ZCK) are installed first with power and gas services in place so that the fire itself can be installed quickly and easily once the room, into which it is installed, is complete. i.e. walls finished (painted/papered) and floor coverings in place. Product Dimensions (Showing product fitted inside ZCK): (mm) 960 = Minimum Cavity Dimensions: (mm) A 960 Order of installation: IB850 – 4 sided fascia Cavity created and flue installed ZCK fitted and gas & power services installed 3 IB850 – 3 sided fascia After the room/dwelling is complete finally install and commission the gas fireplace. Gas Specifications: Heat output Gas Input Gas Connection Electrical Connection = 9.0kW = 42MJ/h = Front RH corner of heater = 240V 3 Pin plug within 1.2m of the rear LH corner of heater Flueing the heater: This heater is to be conventionally flued with a 100mm dia flue system, in accordance with the requirements of NZS 5261 / AS5601 / AG601-2000. A power flue system is also available, please ask your agent, or visit our web site for details on this. 630109_6 IB850 Info sheet for builders and architects (old code G8869)

 Open the catalog to page 1
IB850-2

Ventilation: It is important to remember that Clause G4.2.0 of the New Zealand Building Code and Section 2.6.6 of the New Zealand Gas Installation Standard calls for additional ventilation into living spaces where open flued natural draught appliances are installed. Both of these codes provide formulae and tables for calculating the required ventilation given the size of the living space and the gas input of the appliance. Ceiling vent The following are the recommended minimum clearances for the location of any electrical equipment (such as Plasma TV, LCD TV or home theatre) above an escea gas...

 Open the catalog to page 2

All Escea catalogs and technical brochures

  1. DF960

    2  Pages

  2. DF700

    2  Pages

  3. DF990

    2  Pages

  4. ST500

    1  Page

  5. IB1100

    2  Pages

  6. IB600

    2  Pages

  7. EW5000

    2  Pages

  8. EF5000

    2  Pages

  9. ST900

    1  Page

  10. FS730

    2  Pages

  11. DX1500

    2  Pages

  12. DX1000

    2  Pages

  13. DL1100

    2  Pages

  14. DL850

    2  Pages

  15. AF960

    2  Pages

  16. AF700

    2  Pages

  17. Escea brochure

    36  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.