Catalog excerpts
PRODUCT PORTFOLIO TECHNICAL DATA SHEETS (LAST UPDATED 04/2019) EP5
Open the catalog to page 1H ENERCON ENERGY FOR THE WORLD
Open the catalog to page 2TECHNICAL DATA Last updated: 04/2019. Technical information subject to change. Nominal power 900 kW Type directly driven, separately Wind class (IEC) IEC IA excited annular generator Wind zone (DIBt) WZ 4 GK I Cooling system air cooling system Turbine concept gearless, variable speed, FEATURES STANDARD OPTIONAL full power converter Design service life 20 years FACTS and transmission X Cut in wind speed 2.5 m/s ENERCON SCADA X Cut out wind speed 34 m/s ENERCON storm control X Ice detection system X Extreme wind speed at hub height (3-second gust) 70 m/s Power curve method Rotational speed...
Open the catalog to page 3TECHNICAL DATA Last updated: 04/2019. Technical information subject to change. Nominal power 800 kW Type directly driven, separately Wind class (IEC) IEC IIA excited annular generator Wind zone (DIBt) WZ III Cooling system air cooling system Turbine concept gearless, variable speed, FEATURES STANDARD OPTIONAL full power converter Design service life 20 years FACTS and transmission X Cut in wind speed 2.5 m/s ENERCON SCADA X Cut out wind speed 34 m/s ENERCON storm control X Ice detection system X Extreme wind speed at hub height (3-second gust) 59.5 m/s Power curve method Rotational speed...
Open the catalog to page 5aENERCON ENER
Open the catalog to page 6TECHNICAL DATA Last updated: 04/2019. Technical information subject to change. Nominal power 800 kW Wind class (IEC) IEC SA Wind zone (DIBt) WZ II exp. / WZ 3 GK I / WZ 4 GK II Turbine concept gearless, variable speed, full power converter Design service life 20 years Cut in wind speed 2.5 m/s Cut out wind speed 34 m/s Extreme wind speed at hub height (3-second gust) 57 m/s (HH 60 / 73 m) 55 m/s (HH 50 m) Rotational speed 10.0 - 27.7 rpm Ambient temperature for normal operation -10 °C to +40 °C Extreme temperature range -20 °C to +50 °C Grid feed / control system ENERCON inverter Grid...
Open the catalog to page 7TECHNICAL DATA Last updated: 04/2019. Technical information subject to change. Nominal power 2,300 kW Wind class (IEC) IEC IA and IEC IIA Wind zone (DIBt) WZ III / WZ 4 GK I Turbine concept gearless, variable speed, full power converter Design service life 20 years Cut in wind speed 2.5 m/s Cut out wind speed 34 m/s Extreme wind speed at hub height (3-second gust) 59.5 m/s (IEC IIA) 70 m/s (IEC IA) Rotational speed 6.0 - 20.5 rpm Ambient temperature for normal operation -10 °C to +40 °C Extreme temperature range -20 °C to +50 °C Grid feed / control system ENERCON inverter Grid frequency 50...
Open the catalog to page 9TECHNICAL DATA Last updated: 04/2019. Technical information subject to change. Nominal power 2,000 kW / 2,300 kW Wind class (IEC) IEC IIA Wind zone (DIBt) WZ 4 GK I Turbine concept gearless, variable speed, full power converter Design service life 20 years Cut in wind speed 2.5 m/s Cut out wind speed 34 m/s Extreme wind speed at hub height (3-second gust) 59.5 m/s Rotational speed 5.0 - 17.4 rpm (2,000 kW) 5.0 - 17.5 rpm (2,300 kW) Ambient temperature for normal operation -10 °C to +40 °C Extreme temperature range -20 °C to +50 °C Grid feed / control system ENERCON inverter Grid frequency...
Open the catalog to page 11H ENERCON ENERGY FOR THE WORLD
Open the catalog to page 12TECHNICAL DATA Last updated: 04/2019. Technical information subject to change. Nominal power 2,350 kW / 3,000 kW Wind class (IEC) IEC IA and IEC IIA Wind zone (DIBt) WZ 4 GK I Turbine concept gearless, variable speed, full power converter Design service life 25 years Cut in wind speed 2.5 m/s Cut out wind speed 34 m/s Extreme wind speed at hub height (3-second gust) 70 m/s (IEC IA) 59.5 m/s (IEC IIA) Rotational speed 5.0 - 17.5 rpm Ambient temperature for normal operation -10 °C to +40 °C Extreme temperature range -20 °C to +50 °C Grid feed / control system ENERCON inverter Grid frequency...
Open the catalog to page 13Nominal power Wind class (IEC) Wind zone (DIBt) Turbine concept Design service life Cut in wind speed Cut out wind speed Extreme wind speed at hub height (3-second gust) Rotational speed Ambient temperature for normal operation Extreme temperature range Grid feed / control system Grid frequency Sound power level 2,350 kW IEC IIA WZ 4 GK I + II gearless, variable speed, full power converter 25 years 2.5 m/s 34 m/s 59.5 m/s 5.0 - 16.5 rpm -10 °C to +40 °C -20 °C to +50 °C ENERCON inverter 50 Hz / 60 Hz 91.0 - 105.0 dB(A)* Yield and noise-optimised operation. Further modes on request. Type...
Open the catalog to page 15TECHNICAL DATA Last updated: 04/2019. Technical information subject to change. Nominal power 2,000 kW / 2,350 kW Wind class (IEC) IEC IIIA Wind zone (DIBt) WZ 2 GK I + II Turbine concept gearless, variable speed, full power converter Design service life 25 years Cut in wind speed 2.5 m/s Cut out wind speed 34 m/s Extreme wind speed at hub height (3-second gust) 52.5 m/s Rotational speed 4.8 - 14.4 rpm (2,000 kW) 4.8 - 14.6 rpm (2,300 kW) Ambient temperature for normal operation -10 °C to +40 °C Extreme temperature range -20 °C to +50 °C Grid feed / control system ENERCON inverter Grid...
Open the catalog to page 17TECHNICAL DATA Last updated: 04/2019. Technical information subject to change. Nominal power 3,050 kW Wind class (IEC) IEC IIA Wind zone (DIBt) WZ III / WZ 4 GK I Turbine concept gearless, variable speed, full power converter Design service life 20 years Cut in wind speed 2.5 m/s Cut out wind speed 34 m/s Extreme wind speed at hub height (3-second gust) 59.5 m/s Rotational speed 4.8 - 14.2 rpm Ambient temperature for normal operation -10 °C to +40 °C Extreme temperature range -20 °C to +50 °C Grid feed / control system ENERCON inverter Grid frequency 50 Hz / 60 Hz Sound power level 87.5 -...
Open the catalog to page 19TECHNICAL DATA 15 Last updated: 04/2019. Technical information subject to change. Nominal power Wind class (IEC) Wind zone (DIBt) Turbine concept Design service life Cut in wind speed Cut out wind speed Extreme wind speed at hub height (3-second gust) Rotational speed Ambient temperature for normal operation Extreme temperature range Grid feed / control system Grid frequency Sound power level 3,000 kW / 3,200 kW IEC IIA WZ III / WZ 4 GK I + II (3,000 kW) WZ 4 GK I + II (3,200 kW) gearless, variable speed, full power converter 25 years 2.5 m/s 34 m/s 59.5 m/s 4.4 - 12.4 rpm (3,000 kW) 4.4 -...
Open the catalog to page 21All Enercon catalogs and technical brochures
-
ENERCON E-CHARGER 600
3 Pages
-
E-CHARGING PARK
2 Pages
-
E-138 EP3
18 Pages
-
PRODUCT PORTFOLIO
2 Pages
-
EN_PUE_en_web
17 Pages
-
EN_TuS_en_web
23 Pages