t: 01384 275800 f: 01384 275810 e: [email protected] visit: eltaselect.com Twinflow STDR Product Brochure MIXED FLOW HEAT RECOVERY
Open the catalog to page 1Twinflow STDR MORE INFORMATION Accessories & Wiring Data Optimum Energy Efficiency Point Dimensional Data Performance, SFP & Electrical Data Sound Data QUICK FACTS Roof Mounted Direct Drive Twin Centrifugal Fan The Twinflow STDR...EC incorporates the BAT (Best Available Technology) Vpro backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of twin roof fans are suitable for external mounting, manufactured in Aluzinc with a natural finish. ü 10 standard sizes from 200mm to 710mm....
Open the catalog to page 2Twinflow STDR Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Product Code Speed r/min Airflow m³/s @ Static Pressure Pa. 25 Motor Electrical Data Overall Efficiency % Overall static efficiency, r/min and FMEG values are per ISO 12759 installation category C. FLC Amps @ 230V / 1Ph / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. Sound Data SINGLE Phase - 220V to 240V / 50Hz Sound Power Level dBW @ Octave Band Hz Product Code Speed...
Open the catalog to page 3Twinflow STDR Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz Product Code Speed r/min Airflow m³/s @ Static Pressure Pa. Airflow 0 Overall Efficiency % Motor Electrical Data FMEG Overall static efficiency, r/min and FMEG values are per ISO 12759 installation category C. FLC Amps @ 400V / 3Ph / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. Sound Data THREE Phase - 380V to 415V / 50Hz Sound Power Level dBW @ Octave Band Hz Product...
Open the catalog to page 4Twinflow STDR Accessories & Wiring Data For more information on Accessories & Wiring Diagrams, please see individual product downloads, or visit eltaselect.com/information-centre SINGLE Phase - 220V to 240V / 50Hz Product Code Electronic Controller Flexible Connections (each) Transformer Controller Clamps (each) Wiring Diagram No.no Please enquire. THREE Phase - 380V to 415V / 50Hz Product Code Transformer Controller Flexible Connections (each) Clamps (each) Please enquire. Optimum Energy Efficiency Point SINGLE Phase - 220V to 240V / 50Hz Speed r/min Product Code Speed r/min Product Code Elta...
Open the catalog to page 5Twinflow STDR Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Airflow 0 m³ / s W / (L/s) m³ / s W / (L/s) m³ / s Motor Electrical Data Overall Efficiency FMEG % Overall static efficiency, r/min and FMEG values are per ISO 12759 installation category C. FLC Amps @ 230V / 1Ph / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. A Variable Speed Drive is intergrated...
Open the catalog to page 6Twinflow STDR Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Airflow 0 m³ / s W / (L/s) m³ / s W / (L/s) m³ / s Overall Efficiency FMEG % Motor Electrical Data Overall static efficiency, r/min and FMEG values are per ISO 12759 installation category C. FLC Amps @ 230V / 1Ph / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. A Variable Speed Drive is intergrated...
Open the catalog to page 7Twinflow STDR Sound Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Inlet Outlet Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Elta Fans Limited has a policy of continuous product development and...
Open the catalog to page 8Twinflow STDR Sound Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Elta Fans Limited has a policy of continuous product development and improvement...
Open the catalog to page 9Twinflow STDR Performance, SFP & Electrical Data THREE Phase - 380V to 480V / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Airflow 0 m³ / s W / (L/s) m³ / s W / (L/s) m³ / s Motor Electrical Data Overall Efficiency FMEG % Overall static efficiency, r/min and FMEG values are per ISO 12759 installation category C. FLC Amps @ 400V / 3Ph / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. A Variable Speed Drive is intergrated...
Open the catalog to page 10Twinflow STDR Sound Data THREE Phase - 380V to 480V / 50Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Elta Fans Limited has a policy of continuous product development and improvement and therefore...
Open the catalog to page 1116 Pages
14 Pages
8 Pages
10 Pages
28 Pages
12 Pages
12 Pages
8 Pages
32 Pages
4 Pages
8 Pages
7 Pages
6 Pages
15 Pages
5 Pages
6 Pages
5 Pages
5 Pages
6 Pages
8 Pages
8 Pages
5 Pages
4 Pages
6 Pages
4 Pages
5 Pages
5 Pages
5 Pages
11 Pages
15 Pages
6 Pages
15 Pages
15 Pages
15 Pages
16 Pages
16 Pages
5 Pages
5 Pages
6 Pages
6 Pages
7 Pages
6 Pages
9 Pages
11 Pages
5 Pages
7 Pages
14 Pages
16 Pages
18 Pages
6 Pages
6 Pages
8 Pages
5 Pages
7 Pages
5 Pages
11 Pages
12 Pages
16 Pages
17 Pages
13 Pages
10 Pages
5 Pages
7 Pages
5 Pages
6 Pages
16 Pages
12 Pages
13 Pages
28 Pages
12 Pages
12 Pages
4 Pages