JETVENT INDUCTION
1 /16Pages

JETVENT INDUCTION

JETVENT INDUCTION
1 /16Pages

Catalog excerpts

JETVENT INDUCTION-1

Induction Ventilation

 Open the catalog to page 1
JETVENT INDUCTION-2

introduction JetVent Centrifugal Induction fans have been specifically designed to provide a high velocity, laminar airflow in a reduced height profile to help overcome problems caused by obstructive structural beams and low overall ceiling heights found in car parks. The innovative design of JetVent Centrifugal Induction fans provides major benefits in terms of reduced installation and running costs as well as effective smoke and contaminant removal. JetVent - the principle The induction ventilation system is based on a number of small, strategically located high velocity fans in place of the...

 Open the catalog to page 2
JETVENT INDUCTION-3

with the simplest of functio design lies an exceptionally powerful thrusting air belying the modes ^gjm/ing pollutants SEffh en sions of its casing, induction ventilation? There are a number of differences between the conventional mechanical and modern induction ventilation systems, namely; Figure 2.0 Conventional ducted system Figure 3.0 Equivalent induction system layout raditional Ducting Exhaust Point a) The distribution ducting used in traditional systems (Figure 2.0) is replaced by a number of small JetVent Centrifugal nduction fans (Figure 3.0) to direct the airflow across the designated...

 Open the catalog to page 3
JETVENT INDUCTION-4

features & benefits The JetVent Centrifugal Induction fan range comprises two standard sizes, 50N and 100N, both with uni-directional airflow. no ductwork requirement By adding momentum to the air, JetVent forces air towards the desired extract points to ensure stagnant fumes and smoke are cleared effectively and efficiently. This principal can minimise or even totally eliminate the requirement for ductwork within a car park. As the JetVent effectively transfers the polluted air towards the point of exhaust which means better use of limited space in underground facilities. By eliminating ductwork,...

 Open the catalog to page 4
JETVENT INDUCTION-5

better security The elimination or reduction in ductwork means a safer, lighter environment with better security due to the increased visibility for CCTV cameras. rigorous testing JetVent is independently tested to meet the exacting standards of EN 12101 – 3:2002 for operating at 300°C for 2 hours. Performance is tested to BS848 – 10:1999 Fans for general purposes - Performance testing of jet fans. air quality JetVent provides an improvement in air quality achieved by mixing the air more effectively, which means the potential risk of contaminant accumulation (beyond specific requirements) is...

 Open the catalog to page 5
JETVENT INDUCTION-6

market applications Elta Fans has a wealth of experience and knowledge which we dedicate to understanding your particular and specific needs. Whether your criteria includes optimising space, specific performance characteristics, low noise level or a high specification finish, the JetVent Centrifugal Induction range continues to enhance Elta’s reputation in the design and supply of specialist ventilation products. JetVent is designed to meet the particular and specific requirements for general ventilation and smoke movement within fully enclosed or open sided car parks, as well as vehicle bays,...

 Open the catalog to page 6
JETVENT INDUCTION-7

Elta Fans has a wealth of experience and knowledge, dedicated to understanding your particular needs

 Open the catalog to page 7
JETVENT INDUCTION-8

specification The JetVent Centrifugal Induction range comprises 50N or 100N thrust types, suitable for ambient temperature operation plus once only 300°C for 2 hour high temperature smoke conditions to European Standard EN12101–3:2002. The two speed motor is suitable for frequency inverter speed control on high speed. casing The all metal fan casing provides a robust construction, assisted by the long lasting paint finish (optional). The integral mounting flanges on the casing allow the unit to be mounted easily to the structure. All casing parts are manufactured from heavy gauge mild sheet steel...

 Open the catalog to page 8
JETVENT INDUCTION-9

Induction Fans Main Exhaust Fans Figure 4.0 Extract from typical car park impulse ventilation schematic The ventilation level to be provided within the car park (in order to limit the concentration of carbon monoxide and other vehicle emissions and to remove smoke in the event of a fire) can be found in the relevant Building Regulations and in BS 7346-7:2006 Components for smoke and heat control systems – Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks. Elta Fans is a major supplier of axial flow fans for fresh air...

 Open the catalog to page 9
JETVENT INDUCTION-10

performance, electrical & wiring data Motors shown below are suitable for the following:- A) General use at temperatures (ambient) +40°C B) One off high temperature use of 300°C for 2 hours C) 400Volt / 3 Phase / 50Hz Electrical Supply D) All thrust figures are measured under test conditions E) Volume flow and velocity figures shown may have been calculated in accordance with test requirements F) All the test data shown has been prepared in accordance with ISO 13350 1999 / BS 848-10-1999 G) dBA figures are free field sound pressure levels at 45° to the outlet wiring diagram SWITCH ISOLATOR HIGH...

 Open the catalog to page 10
JETVENT INDUCTION-12

MIXED FLOW Induction Ventilation

 Open the catalog to page 12
JETVENT INDUCTION-13

MIXED FLOW specification The JetVent Mixed Flow induction unit provides 50N of thrust and is suitable for ambient operating temperatures of up to 70°C. The all metal fan casing provides a long lasting and robust construction. Motors are highly efficient induction type, protected to IP55 with sealed for life ball bearings, standard industrial paint finish and Class F insulation to EN 60034-5, suitable for operating temperatures of up to 70°C. The integral mounting feet on the casing allow the unit to be mounted directly to the ceiling. All casing parts are manufactured from pre-galvanised sheet...

 Open the catalog to page 13
JETVENT INDUCTION-14

MIXED FLOW performance, electrical & wiring data Motors shown below are suitable for the following:A) General use at temperatures (ambient) +40ºC B) 400Volt / 3 Phase / 50Hz Electrical Supply C) All thrust figures are measured under test conditions D) Volume flow and velocity figures shown may have been calculated in accordance with test requirements E) All the test data shown has been prepared in accordance with ISO 13350 1999 / BS 848-10-1999 G) dBA figures are free field sound pressure levels at 45º to the outlet Product Code Thrust Volume Flow Velocity m/s Newtons Rate m3/s Product Code Speed...

 Open the catalog to page 14

All Elta catalogs and technical brochures

  1. EKA

    16  Pages

  2. MULTIFLOW SEM

    14  Pages

  3. RAPTOR SFB

    8  Pages

  4. MARINE EMEC

    10  Pages

  5. MULTIFloW MFB

    28  Pages

  6. JetVent

    12  Pages

  7. MULTIFlow MFC

    32  Pages

  8. Smoke Vent

    8  Pages

  9. Compact SCDA

    7  Pages

  10. Compact SCPA

    6  Pages

  11. Compact Range

    15  Pages

  12. Multiflow SMT

    6  Pages

  13. Multiflow SMC

    8  Pages

  14. Multiflow SMB

    8  Pages

  15. ZOO Fan SDF

    6  Pages

  16. Wall Fan HWFA

    5  Pages

  17. Viper SCC

    11  Pages

  18. Twinflow STD

    15  Pages

  19. Singleflow SSD

    15  Pages

  20. Quietflow SQS

    15  Pages

  21. Quietflow SQT

    15  Pages

  22. Qube SQU

    6  Pages

  23. Qube SQU-HT

    6  Pages

  24. Powerduct SPD

    7  Pages

  25. Jetstream SJS

    6  Pages

  26. Jetflow HIT

    9  Pages

  27. Hideaway SH

    11  Pages

  28. Revolution SLC

    14  Pages

  29. Raptor SPA

    16  Pages

  30. Raptor SDA

    18  Pages

  31. PowerPlus SPP

    6  Pages

  32. Miniflow SAMF

    6  Pages

  33. Compact SCP

    8  Pages

  34. SLCX Atex

    7  Pages

  35. Twinflow STDR

    14  Pages

  36. Skyflow SSRV

    16  Pages

  37. Skyflow SSR

    17  Pages

  38. Singleflow SSDR

    13  Pages

  39. Miniflow SMF

    5  Pages

  40. Heritage SCHT

    7  Pages

  41. Heritage SGE

    5  Pages

  42. Heritage SCH

    6  Pages

  43. Jetvent Axials

    12  Pages

  44. BELT DRIVE BD

    13  Pages

  45. LC/SC

    28  Pages

  46. ATEX Fans

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.