Twinflow STDR DCV
11Pages

{{requestButtons}}

Catalog excerpts

Twinflow STDR DCV - 1

t: 01384 275800 f: 01384 275810 e: bs@eltafans.co.uk visit: eltaselect.com Twinflow STDR DCV Product Brochure MIXED FLOW HEAT RECOVERY

Open the catalog to page 1
Twinflow STDR DCV - 2

MORE INFORMATION Accessories & Wiring Data Optimum Energy Efficiency Point Dimensional Data QUICK FACTS Roof Mounted Direct Drive Twin Centrifugal Fan The Twinflow STDR DCV...EC incorporates the BAT (Best Available Technology) Vpro backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of twin roof fans are suitable for external mounting, manufactured in Aluzinc with a natural finish. ü 10 standard sizes from 200mm to 710mm. Performance, SFP & Electrical Data Sound Data ü Air...

Open the catalog to page 2
Twinflow STDR DCV - 3

Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Airflow 0 m³ / s W / (L/s) m³ / s W / (L/s) m³ / s Motor Electrical Data Overall Efficiency FMEG % Overall static efficiency, r/min and FMEG values are per ISO 12759 installation category C. FLC Amps @ 230V / 1Ph / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. A Variable Speed Drive is intergrated within the...

Open the catalog to page 3
Twinflow STDR DCV - 4

Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Airflow 0 m³ / s W / (L/s) m³ / s W / (L/s) m³ / s Overall Efficiency FMEG % Motor Electrical Data Overall static efficiency, r/min and FMEG values are per ISO 12759 installation category C. FLC Amps @ 230V / 1Ph / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. A Variable Speed Drive is intergrated within the...

Open the catalog to page 4
Twinflow STDR DCV - 5

Sound Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Inlet Outlet Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Elta Fans Limited has a policy of continuous product development and...

Open the catalog to page 5
Twinflow STDR DCV - 6

Sound Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Elta Fans Limited has a policy of continuous product development and improvement and...

Open the catalog to page 6
Twinflow STDR DCV - 7

Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Airflow 0 m³ / s W / (L/s) m³ / s W / (L/s) m³ / s Motor Electrical Data Overall Efficiency FMEG % Overall static efficiency, r/min and FMEG values are per ISO 12759 installation category C. FLC Amps @ 400V / 3Ph / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. A Variable Speed Drive is intergrated within the...

Open the catalog to page 7
Twinflow STDR DCV - 8

Sound Data THREE Phase - 380V to 415V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Elta Fans Limited has a policy of continuous product development and improvement and...

Open the catalog to page 8
Twinflow STDR DCV - 9

Accessories & Wiring Data For more information on Accessories & Wiring Diagrams, please see individual product downloads, or visit eltaselect.com/information-centre SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Electronic Controller Flexible Connections (each) Clamps (each) Silencer 1200mm Wiring Diagram Long No.no Please enquire. THREE Phase - 380V to 415V / 50Hz or 60Hz Product Code Electronic Controller Flexible Connections (each) Clamps (each) Wiring Diagram No.no Product Code Please enquire. Optimum Energy Efficiency Point SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product...

Open the catalog to page 9
Twinflow STDR DCV - 10

Dimensional Data Product Code Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltaselect & @eltafans

Open the catalog to page 10
Twinflow STDR DCV - 11

BUILDING SERVICES APPLIED TECHNOLOGY e-mail: bs@eltafans.co.uk e-mail: at@eltafans.co.uk e-mail: export@eltafans.co.uk 46 Third Avenue Pensnett Trading Estate Kingswinford, West Midlands DY6 7US, United Kingdom 17 Barnes Wallis Road Segensworth East Industrial Estate Fareham, Hampshire PO15 5ST, United Kingdom 17 Barnes Wallis Road Segensworth East Industrial Estate Fareham, Hampshire PO15 5ST, United Kingdom A member of HEVAC ASSOCIATION GROUP LIMITED

Open the catalog to page 11

All Elta Fans catalogs and technical brochures

  1. MULTIFloW MFB

    28 Pages

  2. JetVent

    12 Pages

  3. MULTIFlow MFC

    32 Pages

  4. Smoke Vent

    8 Pages

  5. Compact SCDA

    7 Pages

  6. Compact SCPA

    6 Pages

  7. Compact Range

    15 Pages

  8. ZOO Fan SDF

    6 Pages

  9. Viper SCC

    11 Pages

  10. Twinflow STD

    15 Pages

  11. Singleflow SSD

    15 Pages

  12. Quietflow SQS

    15 Pages

  13. Quietflow SQT

    15 Pages

  14. Qube SQU

    6 Pages

  15. Qube SQU-HT

    6 Pages

  16. Jetflow HIT

    9 Pages

  17. Hideaway SH

    11 Pages

  18. Revolution SLC

    14 Pages

  19. Raptor SPA

    16 Pages

  20. Raptor SDA

    18 Pages

  21. Compact SCP

    8 Pages

  22. SLCX Atex

    7 Pages

  23. Twinflow STDR

    14 Pages

  24. Skyflow SSRV

    16 Pages

  25. Skyflow SSR

    17 Pages

  26. Miniflow SMF

    5 Pages

  27. Heritage SGE

    5 Pages

  28. Heritage SCH

    6 Pages

  29. Jetvent Axials

    12 Pages

  30. BELT DRIVE BD

    13 Pages

  31. LC/SC

    28 Pages

  32. ATEX Fans

    4 Pages