Catalog excerpts
t: 01384 275800 f: 01384 275810 e: bs@eltafans.co.uk visit: eltaselect.com Twinflow STDR DCV Product Brochure MIXED FLOW HEAT RECOVERY
Open the catalog to page 1MORE INFORMATION Accessories & Wiring Data Optimum Energy Efficiency Point Dimensional Data QUICK FACTS Roof Mounted Direct Drive Twin Centrifugal Fan The Twinflow STDR DCV...EC incorporates the BAT (Best Available Technology) Vpro backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of twin roof fans are suitable for external mounting, manufactured in Aluzinc with a natural finish. ü 10 standard sizes from 200mm to 710mm. Performance, SFP & Electrical Data Sound Data ü Air...
Open the catalog to page 2Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Airflow 0 m³ / s W / (L/s) m³ / s W / (L/s) m³ / s Motor Electrical Data Overall Efficiency FMEG % Overall static efficiency, r/min and FMEG values are per ISO 12759 installation category C. FLC Amps @ 230V / 1Ph / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. A Variable Speed Drive is intergrated within the...
Open the catalog to page 3Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Airflow 0 m³ / s W / (L/s) m³ / s W / (L/s) m³ / s Overall Efficiency FMEG % Motor Electrical Data Overall static efficiency, r/min and FMEG values are per ISO 12759 installation category C. FLC Amps @ 230V / 1Ph / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. A Variable Speed Drive is intergrated within the...
Open the catalog to page 4Sound Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Inlet Outlet Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Elta Fans Limited has a policy of continuous product development and...
Open the catalog to page 5Sound Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Elta Fans Limited has a policy of continuous product development and improvement and...
Open the catalog to page 6Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Airflow 0 m³ / s W / (L/s) m³ / s W / (L/s) m³ / s Motor Electrical Data Overall Efficiency FMEG % Overall static efficiency, r/min and FMEG values are per ISO 12759 installation category C. FLC Amps @ 400V / 3Ph / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. A Variable Speed Drive is intergrated within the...
Open the catalog to page 7Sound Data THREE Phase - 380V to 415V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Elta Fans Limited has a policy of continuous product development and improvement and...
Open the catalog to page 8Accessories & Wiring Data For more information on Accessories & Wiring Diagrams, please see individual product downloads, or visit eltaselect.com/information-centre SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Electronic Controller Flexible Connections (each) Clamps (each) Silencer 1200mm Wiring Diagram Long No.no Please enquire. THREE Phase - 380V to 415V / 50Hz or 60Hz Product Code Electronic Controller Flexible Connections (each) Clamps (each) Wiring Diagram No.no Product Code Please enquire. Optimum Energy Efficiency Point SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product...
Open the catalog to page 9Dimensional Data Product Code Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltaselect & @eltafans
Open the catalog to page 10BUILDING SERVICES APPLIED TECHNOLOGY e-mail: bs@eltafans.co.uk e-mail: at@eltafans.co.uk e-mail: export@eltafans.co.uk 46 Third Avenue Pensnett Trading Estate Kingswinford, West Midlands DY6 7US, United Kingdom 17 Barnes Wallis Road Segensworth East Industrial Estate Fareham, Hampshire PO15 5ST, United Kingdom 17 Barnes Wallis Road Segensworth East Industrial Estate Fareham, Hampshire PO15 5ST, United Kingdom A member of HEVAC ASSOCIATION GROUP LIMITED
Open the catalog to page 11All Elta Fans catalogs and technical brochures
-
MULTIFloW MFB
28 Pages
-
JetVent
12 Pages
-
COMPACT POWERPLUS
12 Pages
-
HERITAGE FCE/FCD
8 Pages
-
MULTIFlow MFC
32 Pages
-
Biflow Cylindrical/ Conical
4 Pages
-
Smoke Vent
8 Pages
-
Compact SCDA
7 Pages
-
Compact SCPA
6 Pages
-
Compact Range
15 Pages
-
Window Wall Fan SAX
5 Pages
-
Raptor Panel SRE
6 Pages
-
Ezifit Thru-wall SEWE
5 Pages
-
Ezifit in-wall SEIE
5 Pages
-
Multiflow SMT
6 Pages
-
Multiflow SMC
8 Pages
-
Multiflow SMB
8 Pages
-
Heat Recovery Units
5 Pages
-
SWHR180 Heat Recovery Unit
4 Pages
-
ZOO Fan SDF
6 Pages
-
Ceiling Fan HCF
4 Pages
-
Wall Fan HWFA
5 Pages
-
Raptor Cooler SRC
5 Pages
-
Pedestal Fan HPFA
5 Pages
-
Viper SCC
11 Pages
-
Twinflow STD
15 Pages
-
Slim Qube SSQU-HT
6 Pages
-
Singleflow SSD
15 Pages
-
Quietflow SQS
15 Pages
-
Quietflow SQT
15 Pages
-
Quietflow SQT DCV
16 Pages
-
Quietflow SQS DCV
16 Pages
-
Quietflow Classic SQT
5 Pages
-
Quietflow Classic SQS
5 Pages
-
Qube SQU
6 Pages
-
Qube SQU-HT
6 Pages
-
Powerduct SPD
7 Pages
-
Jetstream SJS
6 Pages
-
Jetflow HIT
9 Pages
-
Hideaway SH
11 Pages
-
Biflow SB (CYL)
5 Pages
-
Biflow SB (CON)
7 Pages
-
Revolution SLC
14 Pages
-
Raptor SPA
16 Pages
-
Raptor SDA
18 Pages
-
PowerPlus SPP
6 Pages
-
Miniflow SAMF
6 Pages
-
Compact SCP
8 Pages
-
Compact PowerPlus SCPP
5 Pages
-
SLCX Atex
7 Pages
-
Raptor SFB Atex
5 Pages
-
Twinflow STDR
14 Pages
-
Skyflow Viper SSC
12 Pages
-
Skyflow SSRV
16 Pages
-
Skyflow SSR
17 Pages
-
Singleflow SSDR
13 Pages
-
Singleflow SSDR DCV
10 Pages
-
Miniflow SMF
5 Pages
-
Heritage SCHT
7 Pages
-
Heritage SGE
5 Pages
-
Heritage SCH
6 Pages
-
JETVENT INDUCTION
16 Pages
-
Jetvent Axials
12 Pages
-
BELT DRIVE BD
13 Pages
-
LC/SC
28 Pages
-
Centrifugal JetVent Mixed
12 Pages
-
JetVent Flanged
12 Pages
-
ATEX Fans
4 Pages