Twinflow STD
15Pages

{{requestButtons}}

Catalog excerpts

Twinflow STD - 1

t: 01384 275800 f: 01384 275810 e: bs@eltafans.co.uk visit: eltaselect.com Twinflow STD Product Brochure MIXED FLOW HEAT RECOVERY

Open the catalog to page 1
Twinflow STD - 2

NEW LARGER MODELS ADDED MORE INFORMATION Sound Data Performance, SFP & Electrical Data Accessories & Wiring Data Optimum Energy Efficiency Point Dimensional Data The Twinflow STD...EC incorporates the BAT (Best Available Technology) Vpro backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of in-line centrifugal twin fans, designed to overcome space restrictions, is suitable for internal mounting. QUICK FACTS ü 11 standard sizes from 100mm to 710mm. ü Air volume flow rates up...

Open the catalog to page 2
Twinflow STD - 3

Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Product Code Speed r/min Airflow m³/s @ Static Pressure Pa. Motor Electrical Data Overall FMEG Efficiency % Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC Amps @ 230V / 1Ph / 50Hz. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. Elta Fans Limited has a policy of continuous product...

Open the catalog to page 3
Twinflow STD - 4

Sound Data SINGLE Phase - 220V to 240V / 50Hz Sound Power Level dBW @ Octave Band Hz Product Code Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Please contact Elta Fans for full sound data. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. Email:...

Open the catalog to page 4
Twinflow STD - 5

Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz Product Code Airflow m³/s @ Static Pressure Pa. Speed Airflow r/min SFP 3 Ph r Outlet Breakout Inlet 3 Ph Y Outlet Breakout Inlet Motor Electrical Data Overall FMEG Efficiency % Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC Amps @ 400V / 3Ph / 50Hz. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative...

Open the catalog to page 5
Twinflow STD - 6

Accessories & Wiring Data For more information on Accessories & Wiring Diagrams, please see individual product downloads, or visit eltaselect.com/information-centre SINGLE Phase - 220V to 240V / 50Hz Auto Changeover Panels Product Code Electronic Controller Transformer Controller Flexible Connections (each) Clamps (each) Electric Heater Battery Panel Filter Product Code Please enquire. THREE Phase - 380V to 415V / 50Hz Product Code Transformer Controller Flexible Connections (each) Clamps (each) Please enquire. Optimum Energy Efficiency Point SINGLE Phase - 220V to 240V / 50Hz Product Code...

Open the catalog to page 6
Twinflow STD - 7

Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Motor Electrical Data Overall FMEG Efficiency FLC Input % Amps kW Outlet Breakout Outlet Breakout Outlet Breakout A variable speed drive is integrated within the fan. Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC Amps @ 230V / 1Ph / 50Hz. Data...

Open the catalog to page 7
Twinflow STD - 8

Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Motor Electrical Data Overall FMEG Efficiency FLC Input % Amps kW A variable speed drive is integrated within the fan. Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC Amps @ 230V / 1Ph / 50Hz. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound...

Open the catalog to page 8
Twinflow STD - 9

Sound Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Please contact Elta Fans for full sound data. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be...

Open the catalog to page 9
Twinflow STD - 10

Sound Data SINGLE Phase - 220V to 240V / 50Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Please contact Elta Fans for full sound data. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on...

Open the catalog to page 10
Twinflow STD - 11

Performance, SFP & Electrical Data THREE Phase - 380V to 480V / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Motor Electrical Data Overall FMEG Efficiency FLC Input % Amps kW A variable speed drive is integrated within the fan. Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC Amps @ 230V / 1Ph / 50Hz. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a...

Open the catalog to page 11

All Elta Fans catalogs and technical brochures

  1. MULTIFloW MFB

    28 Pages

  2. JetVent

    12 Pages

  3. MULTIFlow MFC

    32 Pages

  4. Smoke Vent

    8 Pages

  5. Compact SCDA

    7 Pages

  6. Compact SCPA

    6 Pages

  7. Compact Range

    15 Pages

  8. ZOO Fan SDF

    6 Pages

  9. Viper SCC

    11 Pages

  10. Singleflow SSD

    15 Pages

  11. Quietflow SQS

    15 Pages

  12. Quietflow SQT

    15 Pages

  13. Qube SQU

    6 Pages

  14. Qube SQU-HT

    6 Pages

  15. Jetflow HIT

    9 Pages

  16. Hideaway SH

    11 Pages

  17. Revolution SLC

    14 Pages

  18. Raptor SPA

    16 Pages

  19. Raptor SDA

    18 Pages

  20. Compact SCP

    8 Pages

  21. SLCX Atex

    7 Pages

  22. Twinflow STDR

    14 Pages

  23. Skyflow SSRV

    16 Pages

  24. Skyflow SSR

    17 Pages

  25. Miniflow SMF

    5 Pages

  26. Heritage SGE

    5 Pages

  27. Heritage SCH

    6 Pages

  28. Jetvent Axials

    12 Pages

  29. BELT DRIVE BD

    13 Pages

  30. LC/SC

    28 Pages

  31. ATEX Fans

    4 Pages