t: 01384 275800 f: 01384 275810 e: bs@eltafans.co.uk visit: eltaselect.com Skyflow SSRV Product Brochure MIXED FLOW HEAT RECOVERY
Open the catalog to page 1Skyflow SSRV MORE INFORMATION Sound Data Performance, SFP & Electrical Data Accessories & Wiring Data Optimum Energy Efficiency Point Dimensional Data QUICK FACTS Roof Mounted Vertical Extract Fan The Skyflow SSRV incorporates the BAT (Best Available Technology) FE2owlet sickle bladed aerofoil profiled impeller, with serrated trailing edges and winglets powered by the ultra reliable Ziehl-Abegg external rotor motor. The Vertical Skyflow is UV stabilised for a durable, long lasting product, which delivers exceptional performance and noise characteristics, designed to discharge the air at...
Open the catalog to page 2Skyflow SSRV Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Product Code Speed r/min Airflow m³ / s @ Static Pressure Pa 0 Motor Electrical Data Overall Efficiency FMEG FLC SC Input % Amps Amps kW Overall static efficiency and r/min values are as per ISO 12759 installation category C. FLC Amps @ 230V / 1Ph / 50Hz. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. Elta Fans Limited has...
Open the catalog to page 3Skyflow SSRV Sound Data SINGLE Phase - 220V to 240V / 50Hz Sound Power Level dBW @ Octave Band Hz Product Code Speed r/min Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. The inclusion of baffles in these silencers, means that there is additional pressure drop in the system, which needs to be overcome by the fan. Please see relevant product download on the website for the pressure drop value. Why not use the facility in our ‘‘Fans by Elta’’ interactive CD Rom to do the...
Open the catalog to page 4Skyflow SSRV Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz Product Code Speed r/min Airflow m³ / s @ Static Pressure Pa 0 Motor Electrical Data Overall Efficiency FMEG % Overall static efficiency and r/min values are as per ISO 12759 installation category C. FLC Amps @ 400V / 3Ph / 50Hz. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. Elta Fans Limited has a policy of continuous...
Open the catalog to page 5Skyflow SSRV Sound Data THREE Phase - 380V to 415V / 50Hz Sound Power Level dBW @ Octave Band Hz Product Code Speed r/min Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. The inclusion of baffles in these silencers, means that there is additional pressure drop in the system, which needs to be overcome by the fan. Please see relevant product download on the website for the pressure drop value. Why not use the facility in our ‘‘Fans by Elta’’ interactive CD Rom to do the...
Open the catalog to page 6Skyflow SSRV Accessories & Wiring Data For more information on Accessories & Wiring Diagrams, please see individual product downloads, or visit eltaselect.com/information-centre SINGLE Phase - 220V to 240V / 50Hz Product Code Electronic Controller Transformer Controller Soaker Sheet Drop in Silencer 600mm Long Drop in Silencer 900mm Long Drop in Silencer 1200mm Long THREE Phase - 380V to 415V / 50Hz Product Code Transformer Controller Soaker Sheet Drop in Silencer 600mm Long Drop in Silencer 900mm Long Drop in Silencer 1200mm Long Optimum Energy Efficiency Point SINGLE Phase - 220V to 240V...
Open the catalog to page 7Skyflow SSRV Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 1Ph / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Airflow 0 m³ / s W / (L/s) m³ / s W / (L/s) m³ / s W / (L/s) Motor Electrical Data Overall Efficiency FMEG % Overall static efficiency, r/min and FMEG values are as per ISO 12759 installation category C. FLC Amps @ 230V / 1Ph / 50Hz. The overall A-scale sound pressure level is at a distance of three meters with spherical propogation. It is expressed in dB re 20µPa and is presented for comparative purposes only. A variable speed...
Open the catalog to page 8Skyflow SSRV Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 1Ph / 50Hz or 60Hz Product Code Control Voltage Airflow m³/s @ Static Pressure Pa. Airflow 0 m³ / s W / (L/s) m³ / s W / (L/s) m³ / s W / (L/s) Overall Efficiency FMEG % Motor Electrical Data Overall static efficiency, r/min and FMEG values are as per ISO 12759 installation category C. FLC Amps @ 230V / 1Ph / 50Hz. The overall A-scale sound pressure level is at a distance of three meters with spherical propogation. It is expressed in dB re 20µPa and is presented for comparative purposes only. Elta Fans Limited has...
Open the catalog to page 9Skyflow SSRV Sound Data SINGLE Phase - 200V to 277V / 1Ph / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Please contact Elta Fans for full sound data. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described...
Open the catalog to page 10Skyflow SSRV Sound Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Please contact Elta Fans for full sound data. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this...
Open the catalog to page 11All Elta Fans catalogs and technical brochures
-
MULTIFloW MFB
28 Pages
-
JetVent
12 Pages
-
COMPACT POWERPLUS
12 Pages
-
HERITAGE FCE/FCD
8 Pages
-
MULTIFlow MFC
32 Pages
-
Biflow Cylindrical/ Conical
4 Pages
-
Smoke Vent
8 Pages
-
Compact SCDA
7 Pages
-
Compact SCPA
6 Pages
-
Compact Range
15 Pages
-
Window Wall Fan SAX
5 Pages
-
Raptor Panel SRE
6 Pages
-
Ezifit Thru-wall SEWE
5 Pages
-
Ezifit in-wall SEIE
5 Pages
-
Multiflow SMT
6 Pages
-
Multiflow SMC
8 Pages
-
Multiflow SMB
8 Pages
-
Heat Recovery Units
5 Pages
-
SWHR180 Heat Recovery Unit
4 Pages
-
ZOO Fan SDF
6 Pages
-
Ceiling Fan HCF
4 Pages
-
Wall Fan HWFA
5 Pages
-
Raptor Cooler SRC
5 Pages
-
Pedestal Fan HPFA
5 Pages
-
Viper SCC
11 Pages
-
Twinflow STD
15 Pages
-
Slim Qube SSQU-HT
6 Pages
-
Singleflow SSD
15 Pages
-
Quietflow SQS
15 Pages
-
Quietflow SQT
15 Pages
-
Quietflow SQT DCV
16 Pages
-
Quietflow SQS DCV
16 Pages
-
Quietflow Classic SQT
5 Pages
-
Quietflow Classic SQS
5 Pages
-
Qube SQU
6 Pages
-
Qube SQU-HT
6 Pages
-
Powerduct SPD
7 Pages
-
Jetstream SJS
6 Pages
-
Jetflow HIT
9 Pages
-
Hideaway SH
11 Pages
-
Biflow SB (CYL)
5 Pages
-
Biflow SB (CON)
7 Pages
-
Revolution SLC
14 Pages
-
Raptor SPA
16 Pages
-
Raptor SDA
18 Pages
-
PowerPlus SPP
6 Pages
-
Miniflow SAMF
6 Pages
-
Compact SCP
8 Pages
-
Compact PowerPlus SCPP
5 Pages
-
SLCX Atex
7 Pages
-
Raptor SFB Atex
5 Pages
-
Twinflow STDR
14 Pages
-
Twinflow STDR DCV
11 Pages
-
Skyflow Viper SSC
12 Pages
-
Skyflow SSR
17 Pages
-
Singleflow SSDR
13 Pages
-
Singleflow SSDR DCV
10 Pages
-
Miniflow SMF
5 Pages
-
Heritage SCHT
7 Pages
-
Heritage SGE
5 Pages
-
Heritage SCH
6 Pages
-
JETVENT INDUCTION
16 Pages
-
Jetvent Axials
12 Pages
-
BELT DRIVE BD
13 Pages
-
LC/SC
28 Pages
-
Centrifugal JetVent Mixed
12 Pages
-
JetVent Flanged
12 Pages
-
ATEX Fans
4 Pages