Quietflow SQT DCV
16Pages

{{requestButtons}}

Catalog excerpts

Quietflow SQT DCV - 1

t: 01384 275800 f: 01384 275810 e: bs@eltafans.co.uk visit: eltaselect.com Quietflow SQT DCV Product Brochure MIXED FLOW HEAT RECOVERY

Open the catalog to page 1
Quietflow SQT DCV - 2

To find out more about DCV, visit: demandcontrolventilation.com 40°C DEMAND CONTROL VENTILATION More Information Optimum Energy Efficiency Point Dimensional Data Performance, SFP & Electrical Data Sound Data Accessories & Wiring Data QUICK FACTS NEW LARGER MODELS ADDED The Quietflow SQT DCV...ECL incorporates the BAT (Best Available Technology) Vpro backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of acoustically treated in-line centrifugal twin fans are suitable for...

Open the catalog to page 2
Quietflow SQT DCV - 3

Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Product Code Control Speed Airflow Voltage r/min SFP Airflow m³/s @ Static Pressure Pa. 0 Motor Electrical Data Overall FMEG Efficiency FLC Input % 500 Amps kW The overall A-scale sound pressure level is at a distance of three meters with spherical propogation. It is expressed in dB re 20µPa and is presented for comparative purposes only, as in the practice semi reverberant nature of any installation and directivity effects can give a different value. *At 2V the average spherical free-field sound pressure levels cannot be...

Open the catalog to page 3
Quietflow SQT DCV - 4

Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Product Code Control Speed Airflow Voltage r/min SFP Airflow m³/s @ Static Pressure Pa. 0 Motor Electrical Data Overall FMEG Efficiency FLC Input % 500 Amps kW The overall A-scale sound pressure level is at a distance of three meters with spherical propogation. It is expressed in dB re 20µPa and is presented for comparative purposes only, as in the practice semi reverberant nature of any installation and directivity effects can give a different value. *At 2V the average spherical free-field sound pressure levels cannot be...

Open the catalog to page 4
Quietflow SQT DCV - 5

Sound Data SINGLE Phase - 220V to 240V / 50Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Speed Voltage r/min Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation...

Open the catalog to page 5
Quietflow SQT DCV - 6

Sound Data SINGLE Phase - 220V to 240V / 50Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Speed Voltage r/min Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions...

Open the catalog to page 6
Quietflow SQT DCV - 7

Accessories & Wiring Data For more information on Accessories & Wiring Diagrams, please see individual product downloads, or visit eltaselect.com/information-centre SINGLE Phase - 220V to 240V / 50Hz Product Code Flexible Connections (each) Clamps (each) Electric Heater Battery Panel Filter *Both Electric Heater Batteries can be used. Product Code Product Code Please enquire. Can be used with all DCV products. Optimum Energy Efficiency Point SINGLE Phase - 220V to 240V / 50Hz Volume m³/s Speed r/min Product Code Data provided at standard air density of 1.2 kg/m³. Values are per ISO 12759...

Open the catalog to page 7
Quietflow SQT DCV - 8

Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Control Airflow Voltage SFP Airflow m³/s @ Static Pressure Pa. 0 Motor Electrical Data Overall FMEG Efficiency FLC Input % 500 Amps kW A variable speed drive is integrated within the fan. Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC Amps @ 230V / 1Ph / 50Hz. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is...

Open the catalog to page 8
Quietflow SQT DCV - 9

Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Control Airflow Voltage SFP Airflow m³/s @ Static Pressure Pa. 0 Motor Electrical Data Overall FMEG Efficiency FLC Input % 500 Amps kW A variable speed drive is integrated within the fan. Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC Amps @ 230V / 1Ph / 50Hz. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is...

Open the catalog to page 9
Quietflow SQT DCV - 10

Sound Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Please contact Elta Fans for full sound data. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and...

Open the catalog to page 10
Quietflow SQT DCV - 11

Sound Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Please contact Elta Fans for full sound data. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply...

Open the catalog to page 11

All Elta Fans catalogs and technical brochures

  1. MULTIFloW MFB

    28 Pages

  2. JetVent

    12 Pages

  3. MULTIFlow MFC

    32 Pages

  4. Smoke Vent

    8 Pages

  5. Compact SCDA

    7 Pages

  6. Compact SCPA

    6 Pages

  7. Compact Range

    15 Pages

  8. ZOO Fan SDF

    6 Pages

  9. Viper SCC

    11 Pages

  10. Twinflow STD

    15 Pages

  11. Singleflow SSD

    15 Pages

  12. Quietflow SQS

    15 Pages

  13. Quietflow SQT

    15 Pages

  14. Qube SQU

    6 Pages

  15. Qube SQU-HT

    6 Pages

  16. Jetflow HIT

    9 Pages

  17. Hideaway SH

    11 Pages

  18. Revolution SLC

    14 Pages

  19. Raptor SPA

    16 Pages

  20. Raptor SDA

    18 Pages

  21. Compact SCP

    8 Pages

  22. SLCX Atex

    7 Pages

  23. Twinflow STDR

    14 Pages

  24. Skyflow SSRV

    16 Pages

  25. Skyflow SSR

    17 Pages

  26. Miniflow SMF

    5 Pages

  27. Heritage SGE

    5 Pages

  28. Heritage SCH

    6 Pages

  29. Jetvent Axials

    12 Pages

  30. BELT DRIVE BD

    13 Pages

  31. LC/SC

    28 Pages

  32. ATEX Fans

    4 Pages