Catalog excerpts
t: 01384 275800 f: 01384 275810 e: bs@eltafans.co.uk visit: eltaselect.com Quietflow SQS DCV Product Brochure MIXED FLOW HEAT RECOVERY
Open the catalog to page 1To find out more about DCV, visit: demandcontrolventilation.com 40°C DEMAND CONTROL VENTILATION More Information Optimum Energy Efficiency Point Dimensional Data Performance, SFP & Electrical Data Sound Data Accessories & Wiring Data QUICK FACTS NEW LARGER MODELS ADDED The Quietflow SQS...EC DCV incorporates the BAT (Best Available Technology) Vpro backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of acoustically treated single in-line fans are suitable for Demand Control...
Open the catalog to page 2Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Product Code Control Speed Airflow Voltage r/min SFP Airflow m³/s @ Static Pressure Pa. 0 Motor Electrical Data Overall FMEG Efficiency FLC Input % 500 Amps kW Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC Amps @ 230V / 1Ph / 50Hz. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. Elta Fans...
Open the catalog to page 3Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Product Code Control Speed Airflow Voltage r/min SFP Airflow m³/s @ Static Pressure Pa. 0 Motor Electrical Data Overall FMEG Efficiency % 500 Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC Amps @ 230V / 1Ph / 50Hz. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only. Elta Fans Limited has a...
Open the catalog to page 4Sound Data SINGLE Phase - 220V to 240V / 50Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of...
Open the catalog to page 5Sound Data SINGLE Phase - 220V to 240V / 50Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will...
Open the catalog to page 6Accessories & Wiring Data For more information on Accessories & Wiring Diagrams, please see individual product downloads, or visit eltaselect.com/information-centre SINGLE Phase - 220V to 240V / 50Hz Flexible Connections (each) Product Code Electronic Controller Transformer Controller Product Code Clamps (each) Panel Filter Electric Heater Battery Wiring Silencer Silencer Diagram 900mm Long 1200mm Long No. Product Code Please enquire. Can be used with all DCV products. Optimum Energy Efficiency Point SINGLE Phase - 220V to 240V / 50Hz Product Code Speed r/min Data provided at standard air...
Open the catalog to page 7Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Control Airflow Voltage SFP Airflow m³/s @ Static Pressure Pa. 0 Motor Electrical Data Overall FMEG Efficiency % 500 A variable speed drive is integrated within the fan. Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC Amps @ 230V / 1Ph / 50Hz. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for...
Open the catalog to page 8Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Control Airflow Voltage SFP Airflow m³/s @ Static Pressure Pa. 0 Motor Electrical Data Overall FMEG Efficiency FLC Input % 500 Amps kW A variable speed drive is integrated within the fan. Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC Amps @ 230V / 1Ph / 50Hz. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is...
Open the catalog to page 9Sound Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Please contact Elta Fans for full sound data. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and...
Open the catalog to page 10Sound Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz Product Code Sound Power Level dBW @ Octave Band Hz Control Voltage Outlet Breakout Outlet Breakout Outlet Breakout Outlet Breakout Please contact Elta Fans for full sound data. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this...
Open the catalog to page 11All Elta Fans catalogs and technical brochures
-
MULTIFloW MFB
28 Pages
-
JetVent
12 Pages
-
COMPACT POWERPLUS
12 Pages
-
HERITAGE FCE/FCD
8 Pages
-
MULTIFlow MFC
32 Pages
-
Biflow Cylindrical/ Conical
4 Pages
-
Smoke Vent
8 Pages
-
Compact SCDA
7 Pages
-
Compact SCPA
6 Pages
-
Compact Range
15 Pages
-
Window Wall Fan SAX
5 Pages
-
Raptor Panel SRE
6 Pages
-
Ezifit Thru-wall SEWE
5 Pages
-
Ezifit in-wall SEIE
5 Pages
-
Multiflow SMT
6 Pages
-
Multiflow SMC
8 Pages
-
Multiflow SMB
8 Pages
-
Heat Recovery Units
5 Pages
-
SWHR180 Heat Recovery Unit
4 Pages
-
ZOO Fan SDF
6 Pages
-
Ceiling Fan HCF
4 Pages
-
Wall Fan HWFA
5 Pages
-
Raptor Cooler SRC
5 Pages
-
Pedestal Fan HPFA
5 Pages
-
Viper SCC
11 Pages
-
Twinflow STD
15 Pages
-
Slim Qube SSQU-HT
6 Pages
-
Singleflow SSD
15 Pages
-
Quietflow SQS
15 Pages
-
Quietflow SQT
15 Pages
-
Quietflow SQT DCV
16 Pages
-
Quietflow Classic SQT
5 Pages
-
Quietflow Classic SQS
5 Pages
-
Qube SQU
6 Pages
-
Qube SQU-HT
6 Pages
-
Powerduct SPD
7 Pages
-
Jetstream SJS
6 Pages
-
Jetflow HIT
9 Pages
-
Hideaway SH
11 Pages
-
Biflow SB (CYL)
5 Pages
-
Biflow SB (CON)
7 Pages
-
Revolution SLC
14 Pages
-
Raptor SPA
16 Pages
-
Raptor SDA
18 Pages
-
PowerPlus SPP
6 Pages
-
Miniflow SAMF
6 Pages
-
Compact SCP
8 Pages
-
Compact PowerPlus SCPP
5 Pages
-
SLCX Atex
7 Pages
-
Raptor SFB Atex
5 Pages
-
Twinflow STDR
14 Pages
-
Twinflow STDR DCV
11 Pages
-
Skyflow Viper SSC
12 Pages
-
Skyflow SSRV
16 Pages
-
Skyflow SSR
17 Pages
-
Singleflow SSDR
13 Pages
-
Singleflow SSDR DCV
10 Pages
-
Miniflow SMF
5 Pages
-
Heritage SCHT
7 Pages
-
Heritage SGE
5 Pages
-
Heritage SCH
6 Pages
-
JETVENT INDUCTION
16 Pages
-
Jetvent Axials
12 Pages
-
BELT DRIVE BD
13 Pages
-
LC/SC
28 Pages
-
Centrifugal JetVent Mixed
12 Pages
-
JetVent Flanged
12 Pages
-
ATEX Fans
4 Pages