Catalog excerpts
Circular Case Mixed Flow Fans
Open the catalog to page 1MFC series Mixed Flow ‘Circular’ Ducted Fans Advanced, flexible performance fan technology Contents Multiflow Technology Performance Data Electrical Data Dimensional Data • Less space • In-line or end of duct fitting Mounting Arrangements Other Elta Products Multiflow MFC benefits • More performance Multiflow is a trade name of Elta Fans
Open the catalog to page 3Multiflow Technology Benefits Advanced fan engineering Elta Multiflow technology provides for the first time, the ability to select a single direct driven mixed flow fan that can meet a wide selection of alternative performance contours and duty requirements. With fixed The secret of Elta Multiflow blade designs, the choice is to either make a selection from a limited technology lies in its extensively number of fixed performance contours or, consider the more costly researched and patented mixed and less space efficient belt driven variants. flow impeller, which incorporates adjustable...
Open the catalog to page 4Mixed Flow Air Performance Benefits • Non-stall characteristic The inherent aerodynamic benefits of good mixed • Non-overloading power curve flow impeller design provide marked advantages • Wide operating range over conventional axial and centrifugal air performance characteristics. Mixed flow ‘non-stall’ • Greater pressure capability than axial fans airflow properties and a non-overloading absorbed power curve allow a wide range of operating • Greater airflow capability than centrifugal fans Comparative curves MULTIFLOW ‘MIXED FLOW’ Multiflow, mixed flow performance can provide clear...
Open the catalog to page 5Standard Multiflow MFC Range The Multiflow MFC fan range has been designed to provide customers with all the inherent benefits of Elta mixed flow technology by optimising design and performance choice. 9 fan sizes each with 2 alternative speeds and a selection of 5 alternative, factory set impeller blade angles for each model, provide an impressive choice Motor and stator Guide Vanes of 90 standard model/performance options. MFC Standard supply comprises Fully cased, cylindrical model with circular mounting flanges at both ends. Wired terminal box, ready for customer installation.
Open the catalog to page 6Basic Fan Model Reference Improved Performance The unique design of Multiflow MFC fans enables required performance to be achieved from a smaller airstream leaving a Multiflow MFC impeller being more axially orientated. This permits the casing to be closer fan size than is normally achievable with typical conical style, fixed blade mixed flow fans. This is due to the to the impeller periphery, without incurring losses and thereby retaining excellent air performance, power and sound levels. Also, as Multiflow MFC incorporates an impeller of relatively wide air passage design, the resultant...
Open the catalog to page 7Airflow Performance Data Elta fan performance data is achieved through exhaustive testing in the Company’s laboratory and provides an accurate and reliable record of the MFC series performance. Testing has been performed for Type D installation category (fully ducted) to the following current standards. Aerodynamic Performance To ISO 5801 : 1997 (incorporating BS 848 Part 1:1997) Sound Performance To BS 848 Part 2 : 1985 on both Inlet and Outlet sides Pressure Values The ISO 5801 standard suggests that fan pressure should be shown as total or stagnation values, with static pressure...
Open the catalog to page 8How to read Air Performance Data – typical example Model Reference Impeller Speed MFC315 1440 rpm Fan Series Casing Dia (mm) Density 1.2kg/m3 Sound Level spectra when Values shown are the overall In-duct Sound Power levels refer to Sound Level notes and table below. below this contour 71 Overall inlet side variations are shown in sound level 60 data below. Pd, Fan Dynamic Pressure Curve Volume/Pressure Characteristic Impeller Blade Setting selected blade angle opposite page. Factory pre-set blade angle setting reference. Customers specify 1 to Selection Example An airflow of 0.24 m3/sec...
Open the catalog to page 90.10 Sound Level The values shown on the performance curve above are the overall In-duct Sound Power levels on the outlet side of the fan unit. (rel. to 1pW). Sound Level The values shown on the performance curve above are the overall In-duct Sound Power levels on the outlet side of the fan unit. (rel. to 1pW). Inlet side values vary by +1dB. Inlet side values vary by +0dB. The overall dBW values may be adjusted by the ‘A’ reductions in the table below, so as to result in the mean free field spherical radiated dBA value at 3 metres. dBA values should be used for comparative purposes only....
Open the catalog to page 100.4 0.2 Sound Level The values shown on the performance curve above are the overall In-duct Sound Power levels on the outlet side of the fan unit. (rel. to 1pW). Sound Level The values shown on the performance curve above are the overall In-duct Sound Power levels on the outlet side of the fan unit. (rel. to 1pW). Inlet side values vary by +1dB. Inlet side values vary by -1dB. The overall dBW values may be adjusted by the ‘A’ reductions in the table below, so as to result in the mean free field spherical radiated dBA value at 3 metres. dBA values should be used for comparative purposes...
Open the catalog to page 110.05 Sound Level The values shown on the performance curve above are the overall In-duct Sound Power levels on the outlet side of the fan unit. (rel. to 1pW). Sound Level The values shown on the performance curve above are the overall In-duct Sound Power levels on the outlet side of the fan unit. (rel. to 1pW). Inlet side values vary by +1dB. Inlet side values vary by +1dB. The overall dBW values may be adjusted by the ‘A’ reductions in the table below, so as to result in the mean free field spherical radiated dBA value at 3 metres. dBA values should be used for comparative purposes only....
Open the catalog to page 120.05 0.1 Sound Level The values shown on the performance curve above are the overall In-duct Sound Power levels on the outlet side of the fan unit. (rel. to 1pW). Sound Level The values shown on the performance curve above are the overall In-duct Sound Power levels on the outlet side of the fan unit. (rel. to 1pW). Inlet side values vary by +1dB. Inlet side values vary by +1dB. The overall dBW values may be adjusted by the ‘A’ reductions in the table below, so as to result in the mean free field spherical radiated dBA value at 3 metres. dBA values should be used for comparative purposes...
Open the catalog to page 13All Elta Fans catalogs and technical brochures
-
MULTIFloW MFB
28 Pages
-
JetVent
12 Pages
-
COMPACT POWERPLUS
12 Pages
-
HERITAGE FCE/FCD
8 Pages
-
Biflow Cylindrical/ Conical
4 Pages
-
Smoke Vent
8 Pages
-
Compact SCDA
7 Pages
-
Compact SCPA
6 Pages
-
Compact Range
15 Pages
-
Window Wall Fan SAX
5 Pages
-
Raptor Panel SRE
6 Pages
-
Ezifit Thru-wall SEWE
5 Pages
-
Ezifit in-wall SEIE
5 Pages
-
Multiflow SMT
6 Pages
-
Multiflow SMC
8 Pages
-
Multiflow SMB
8 Pages
-
Heat Recovery Units
5 Pages
-
SWHR180 Heat Recovery Unit
4 Pages
-
ZOO Fan SDF
6 Pages
-
Ceiling Fan HCF
4 Pages
-
Wall Fan HWFA
5 Pages
-
Raptor Cooler SRC
5 Pages
-
Pedestal Fan HPFA
5 Pages
-
Viper SCC
11 Pages
-
Twinflow STD
15 Pages
-
Slim Qube SSQU-HT
6 Pages
-
Singleflow SSD
15 Pages
-
Quietflow SQS
15 Pages
-
Quietflow SQT
15 Pages
-
Quietflow SQT DCV
16 Pages
-
Quietflow SQS DCV
16 Pages
-
Quietflow Classic SQT
5 Pages
-
Quietflow Classic SQS
5 Pages
-
Qube SQU
6 Pages
-
Qube SQU-HT
6 Pages
-
Powerduct SPD
7 Pages
-
Jetstream SJS
6 Pages
-
Jetflow HIT
9 Pages
-
Hideaway SH
11 Pages
-
Biflow SB (CYL)
5 Pages
-
Biflow SB (CON)
7 Pages
-
Revolution SLC
14 Pages
-
Raptor SPA
16 Pages
-
Raptor SDA
18 Pages
-
PowerPlus SPP
6 Pages
-
Miniflow SAMF
6 Pages
-
Compact SCP
8 Pages
-
Compact PowerPlus SCPP
5 Pages
-
SLCX Atex
7 Pages
-
Raptor SFB Atex
5 Pages
-
Twinflow STDR
14 Pages
-
Twinflow STDR DCV
11 Pages
-
Skyflow Viper SSC
12 Pages
-
Skyflow SSRV
16 Pages
-
Skyflow SSR
17 Pages
-
Singleflow SSDR
13 Pages
-
Singleflow SSDR DCV
10 Pages
-
Miniflow SMF
5 Pages
-
Heritage SCHT
7 Pages
-
Heritage SGE
5 Pages
-
Heritage SCH
6 Pages
-
JETVENT INDUCTION
16 Pages
-
Jetvent Axials
12 Pages
-
BELT DRIVE BD
13 Pages
-
LC/SC
28 Pages
-
Centrifugal JetVent Mixed
12 Pages
-
JetVent Flanged
12 Pages
-
ATEX Fans
4 Pages