Catalog excerpts
Induction Ventilation
Open the catalog to page 1introduction JetVent Centrifugal Induction fans have been specifically designed to provide a high velocity, laminar airflow in a reduced height profile to help overcome problems caused by obstructive structural beams and low overall ceiling heights found in car parks. The innovative design of JetVent Centrifugal Induction fans provides major benefits in terms of reduced installation and running costs as well as effective smoke and contaminant removal. JetVent - the principle The induction ventilation system is based on a number of small, strategically located high velocity fans in place of...
Open the catalog to page 2with the simplest of functio design lies an exceptionally powerful thrusting air belying the modes ^gjm/ing pollutants SEffh en sions of its casing, induction ventilation? There are a number of differences between the conventional mechanical and modern induction ventilation systems, namely; Figure 2.0 Conventional ducted system Figure 3.0 Equivalent induction system layout raditional Ducting Exhaust Point a) The distribution ducting used in traditional systems (Figure 2.0) is replaced by a number of small JetVent Centrifugal nduction fans (Figure 3.0) to direct the airflow across the...
Open the catalog to page 3features & benefits The JetVent Centrifugal Induction fan range comprises two standard sizes, 50N and 100N, both with uni-directional airflow. no ductwork requirement By adding momentum to the air, JetVent forces air towards the desired extract points to ensure stagnant fumes and smoke are cleared effectively and efficiently. This principal can minimise or even totally eliminate the requirement for ductwork within a car park. As the JetVent effectively transfers the polluted air towards the point of exhaust which means better use of limited space in underground facilities. By eliminating...
Open the catalog to page 4better security The elimination or reduction in ductwork means a safer, lighter environment with better security due to the increased visibility for CCTV cameras. rigorous testing JetVent is independently tested to meet the exacting standards of EN 12101 – 3:2002 for operating at 300°C for 2 hours. Performance is tested to BS848 – 10:1999 Fans for general purposes - Performance testing of jet fans. air quality JetVent provides an improvement in air quality achieved by mixing the air more effectively, which means the potential risk of contaminant accumulation (beyond specific requirements)...
Open the catalog to page 5market applications Elta Fans has a wealth of experience and knowledge which we dedicate to understanding your particular and specific needs. Whether your criteria includes optimising space, specific performance characteristics, low noise level or a high specification finish, the JetVent Centrifugal Induction range continues to enhance Elta’s reputation in the design and supply of specialist ventilation products. JetVent is designed to meet the particular and specific requirements for general ventilation and smoke movement within fully enclosed or open sided car parks, as well as vehicle...
Open the catalog to page 6Elta Fans has a wealth of experience and knowledge, dedicated to understanding your particular needs
Open the catalog to page 7specification The JetVent Centrifugal Induction range comprises 50N or 100N thrust types, suitable for ambient temperature operation plus once only 300°C for 2 hour high temperature smoke conditions to European Standard EN12101–3:2002. The two speed motor is suitable for frequency inverter speed control on high speed. casing The all metal fan casing provides a robust construction, assisted by the long lasting paint finish (optional). The integral mounting flanges on the casing allow the unit to be mounted easily to the structure. All casing parts are manufactured from heavy gauge mild sheet...
Open the catalog to page 8Induction Fans Main Exhaust Fans Figure 4.0 Extract from typical car park impulse ventilation schematic The ventilation level to be provided within the car park (in order to limit the concentration of carbon monoxide and other vehicle emissions and to remove smoke in the event of a fire) can be found in the relevant Building Regulations and in BS 7346-7:2006 Components for smoke and heat control systems – Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks. Elta Fans is a major supplier of axial flow fans for fresh...
Open the catalog to page 9performance, electrical & wiring data Motors shown below are suitable for the following:- A) General use at temperatures (ambient) +40°C B) One off high temperature use of 300°C for 2 hours C) 400Volt / 3 Phase / 50Hz Electrical Supply D) All thrust figures are measured under test conditions E) Volume flow and velocity figures shown may have been calculated in accordance with test requirements F) All the test data shown has been prepared in accordance with ISO 13350 1999 / BS 848-10-1999 G) dBA figures are free field sound pressure levels at 45° to the outlet wiring diagram SWITCH ISOLATOR...
Open the catalog to page 10Product Code
Open the catalog to page 11MIXED FLOW Induction Ventilation
Open the catalog to page 12MIXED FLOW specification The JetVent Mixed Flow induction unit provides 50N of thrust and is suitable for ambient operating temperatures of up to 70°C. The all metal fan casing provides a long lasting and robust construction. Motors are highly efficient induction type, protected to IP55 with sealed for life ball bearings, standard industrial paint finish and Class F insulation to EN 60034-5, suitable for operating temperatures of up to 70°C. The integral mounting feet on the casing allow the unit to be mounted directly to the ceiling. All casing parts are manufactured from pre-galvanised...
Open the catalog to page 13MIXED FLOW performance, electrical & wiring data Motors shown below are suitable for the following:A) General use at temperatures (ambient) +40ºC B) 400Volt / 3 Phase / 50Hz Electrical Supply C) All thrust figures are measured under test conditions D) Volume flow and velocity figures shown may have been calculated in accordance with test requirements E) All the test data shown has been prepared in accordance with ISO 13350 1999 / BS 848-10-1999 G) dBA figures are free field sound pressure levels at 45º to the outlet Product Code Thrust Volume Flow Velocity m/s Newtons Rate m3/s Product Code...
Open the catalog to page 14All Elta Fans catalogs and technical brochures
-
MULTIFloW MFB
28 Pages
-
JetVent
12 Pages
-
COMPACT POWERPLUS
12 Pages
-
HERITAGE FCE/FCD
8 Pages
-
MULTIFlow MFC
32 Pages
-
Biflow Cylindrical/ Conical
4 Pages
-
Smoke Vent
8 Pages
-
Compact SCDA
7 Pages
-
Compact SCPA
6 Pages
-
Compact Range
15 Pages
-
Window Wall Fan SAX
5 Pages
-
Raptor Panel SRE
6 Pages
-
Ezifit Thru-wall SEWE
5 Pages
-
Ezifit in-wall SEIE
5 Pages
-
Multiflow SMT
6 Pages
-
Multiflow SMC
8 Pages
-
Multiflow SMB
8 Pages
-
Heat Recovery Units
5 Pages
-
SWHR180 Heat Recovery Unit
4 Pages
-
ZOO Fan SDF
6 Pages
-
Ceiling Fan HCF
4 Pages
-
Wall Fan HWFA
5 Pages
-
Raptor Cooler SRC
5 Pages
-
Pedestal Fan HPFA
5 Pages
-
Viper SCC
11 Pages
-
Twinflow STD
15 Pages
-
Slim Qube SSQU-HT
6 Pages
-
Singleflow SSD
15 Pages
-
Quietflow SQS
15 Pages
-
Quietflow SQT
15 Pages
-
Quietflow SQT DCV
16 Pages
-
Quietflow SQS DCV
16 Pages
-
Quietflow Classic SQT
5 Pages
-
Quietflow Classic SQS
5 Pages
-
Qube SQU
6 Pages
-
Qube SQU-HT
6 Pages
-
Powerduct SPD
7 Pages
-
Jetstream SJS
6 Pages
-
Jetflow HIT
9 Pages
-
Hideaway SH
11 Pages
-
Biflow SB (CYL)
5 Pages
-
Biflow SB (CON)
7 Pages
-
Revolution SLC
14 Pages
-
Raptor SPA
16 Pages
-
Raptor SDA
18 Pages
-
PowerPlus SPP
6 Pages
-
Miniflow SAMF
6 Pages
-
Compact SCP
8 Pages
-
Compact PowerPlus SCPP
5 Pages
-
SLCX Atex
7 Pages
-
Raptor SFB Atex
5 Pages
-
Twinflow STDR
14 Pages
-
Twinflow STDR DCV
11 Pages
-
Skyflow Viper SSC
12 Pages
-
Skyflow SSRV
16 Pages
-
Skyflow SSR
17 Pages
-
Singleflow SSDR
13 Pages
-
Singleflow SSDR DCV
10 Pages
-
Miniflow SMF
5 Pages
-
Heritage SCHT
7 Pages
-
Heritage SGE
5 Pages
-
Heritage SCH
6 Pages
-
JETVENT INDUCTION
16 Pages
-
Jetvent Axials
12 Pages
-
BELT DRIVE BD
13 Pages
-
LC/SC
28 Pages
-
Centrifugal JetVent Mixed
12 Pages
-
JetVent Flanged
12 Pages
-
ATEX Fans
4 Pages