Impulse Ventilation
Open the catalog to page 1introduction JetVent Axial Impulse fans have been specifically designed to provide a high velocity airflow to help overcome problems caused in part by obstructive structural beams and the low overall ceiling heights found in car parks. The innovative design of the JetVent Axial Impulse fan has been proven to provide major benefits in terms of reduced installation and running costs as well as effective smoke and contaminant movement. excellent performance and safety Technical excellence and innovation in application of our equipment are the cornerstones of any Elta product - JetVent is no...
Open the catalog to page 2JetVent: the principle The impulse ventilation system is based on a number of small, strategically located high velocity fans in place of the large and expensive distribution ductwork traditionally used in car parks. reduced need for, or complete elimination of the large, expensive ducting, the resulting reduction in system resistance means the exhaust fans are typically smaller and consume less energy. Impulse fans operate on well proven tunnel ventilation principles, producing a high velocity jet which adds momentum to the air in front of the fan imparting thrust to all the surrounding...
Open the catalog to page 3features & benefits The JetVent Axial Impulse fan range comprises several standard and non-standard sizes. They are provided with either uni-directional or truly reversible airflow, as well as a number of optional ancillaries. JetVent can run in either normal extract mode or at a once only smoke operation at 300ºC for 2 hours which means cost savings as a single fan provides both general and smoke extract requirements. design appeal By adding momentum to the air, JetVent thrusts air towards the desired extract points to ensure contaminant laden air and smoke are cleared effectively and...
Open the catalog to page 4specification The JetVent Axial Impulse range comprises multiple thrust types, suitable for ambient temperature operation (at 40ºC) plus a one off operation at 200ºC or 300ºC for 2 hour high temperature smoke conditions to European Standard EN12101–3:2002. impeller Adjustable pitch aerofoil section impellers are provided with blades made from high quality pressure die cast aluminium alloy (LM6). Hubs are made from pressure die cast aluminium (LM24). The assembled impellers have their blades positively locked by pinning, which provides added security for operation in the smoke regime....
Open the catalog to page 5performance & electrical data Un-Flanged Units Motors shown below are suitable for the following:A) General use at temperatures (ambient) +40ºC B) One off high temperature use of 300ºC for 2 hours C) 400Volt / 3 Phase / 50Hz Electrical Supply D) All thrust figures are measured under test conditions E) Volume flow and velocity figures shown may have been calculated in accordance with test requirements F) All the test data shown has been prepared in accordance with ISO 13350 1999 / BS 848-10-1999 JetVent - Uni Directional - Standard Thrust Product Code Thrust Newtons Volume Flow Rate m3/s...
Open the catalog to page 6dimensional data - JetVent Axial Uni Directional Product Code Truly Reversible Product Code
Open the catalog to page 7performance & electrical data Flanged Units Motors shown below are suitable for the following:A) General use at temperatures (ambient) +40ºC B) One off high temperature use of 300ºC for 2 hours C) 400Volt / 3 Phase / 50Hz Electrical Supply D) All thrust figures are measured under test conditions E) Volume flow and velocity figures shown may have been calculated in accordance with test requirements F) All the test data shown has been prepared in accordance with ISO 13350 1999 / BS 848-10-1999 JetVent - Uni Directional - High Thrust Product Code Thrust Newtons Volume Flow Rate m3/s Product...
Open the catalog to page 8dimensional data - JetVent Flanged Uni Directional 4 HOLES ØF OPTIONAL ISOLATOR A B PLAN VIEW ON MOUNTING FEET Product Code Truly Reversible 4 HOLES ØF OPTIONAL ISOLATOR A B PLAN VIEW ON MOUNTING FEET G Product Code
Open the catalog to page 9wirinq diaqrams - both forms Single Speed (D.O.L. - STAR) Two Speed Single Winding HIGH SPEED
Open the catalog to page 10market applications Elta Fans has a wealth of experience and knowledge dedicated to understanding your particular and specific needs. Whether your criteria include optimising space, specific performance characteristics, low noise level or a high specification finish, the JetVent Axial range continues to enhance Elta’s reputation in the design and supply of specialist ventilation products. JetVent is designed to meet the requirements for general ventilation and smoke extract of fully enclosed or open sided car parks, as well as vehicle bays, metro stations and other applications such as...
Open the catalog to page 11carparkventilation.com Innovation, Application, Determination Elta Fans Ltd 17 Barnes Wallis Road, Segensworth East Industrial Estate, Fareham, Hampshire, P015 5ST, United Kingdom. Visit: eltafans.com e-mail: mailbox@eltafans.co.uk Applied Technology: Building Services:
Open the catalog to page 12All Elta Fans catalogs and technical brochures
-
MULTIFloW MFB
28 Pages
-
JetVent
12 Pages
-
COMPACT POWERPLUS
12 Pages
-
HERITAGE FCE/FCD
8 Pages
-
MULTIFlow MFC
32 Pages
-
Biflow Cylindrical/ Conical
4 Pages
-
Smoke Vent
8 Pages
-
Compact SCDA
7 Pages
-
Compact SCPA
6 Pages
-
Compact Range
15 Pages
-
Window Wall Fan SAX
5 Pages
-
Raptor Panel SRE
6 Pages
-
Ezifit Thru-wall SEWE
5 Pages
-
Ezifit in-wall SEIE
5 Pages
-
Multiflow SMT
6 Pages
-
Multiflow SMC
8 Pages
-
Multiflow SMB
8 Pages
-
Heat Recovery Units
5 Pages
-
SWHR180 Heat Recovery Unit
4 Pages
-
ZOO Fan SDF
6 Pages
-
Ceiling Fan HCF
4 Pages
-
Wall Fan HWFA
5 Pages
-
Raptor Cooler SRC
5 Pages
-
Pedestal Fan HPFA
5 Pages
-
Viper SCC
11 Pages
-
Twinflow STD
15 Pages
-
Slim Qube SSQU-HT
6 Pages
-
Singleflow SSD
15 Pages
-
Quietflow SQS
15 Pages
-
Quietflow SQT
15 Pages
-
Quietflow SQT DCV
16 Pages
-
Quietflow SQS DCV
16 Pages
-
Quietflow Classic SQT
5 Pages
-
Quietflow Classic SQS
5 Pages
-
Qube SQU
6 Pages
-
Qube SQU-HT
6 Pages
-
Powerduct SPD
7 Pages
-
Jetstream SJS
6 Pages
-
Jetflow HIT
9 Pages
-
Hideaway SH
11 Pages
-
Biflow SB (CYL)
5 Pages
-
Biflow SB (CON)
7 Pages
-
Revolution SLC
14 Pages
-
Raptor SPA
16 Pages
-
Raptor SDA
18 Pages
-
PowerPlus SPP
6 Pages
-
Miniflow SAMF
6 Pages
-
Compact SCP
8 Pages
-
Compact PowerPlus SCPP
5 Pages
-
SLCX Atex
7 Pages
-
Raptor SFB Atex
5 Pages
-
Twinflow STDR
14 Pages
-
Twinflow STDR DCV
11 Pages
-
Skyflow Viper SSC
12 Pages
-
Skyflow SSRV
16 Pages
-
Skyflow SSR
17 Pages
-
Singleflow SSDR
13 Pages
-
Singleflow SSDR DCV
10 Pages
-
Miniflow SMF
5 Pages
-
Heritage SCHT
7 Pages
-
Heritage SGE
5 Pages
-
Heritage SCH
6 Pages
-
JETVENT INDUCTION
16 Pages
-
BELT DRIVE BD
13 Pages
-
LC/SC
28 Pages
-
Centrifugal JetVent Mixed
12 Pages
-
JetVent Flanged
12 Pages
-
ATEX Fans
4 Pages