Product catalog summary
Overview: The G2 Multi Tubular Heat Exchanger is designed for high efficiency and robust performance, featuring a unique design that maximizes heat transfer surface area. It is available in four models with power outputs ranging from 30-kW to 122-kW.
Specifications:
  • Models: G2-HE-30T, G2-HE-49T, G2-HE-85T, G2-HE-122T
  • Primary Circuit: Made from BS 316L stainless steel with 1” BSP male fittings, supporting a maximum working pressure of 4 bar.
  • Secondary Circuit: Comprises a bundle of 37 titanium tubes with 1½” / 50mm stepped ABS unions, also supporting a maximum working pressure of 4 bar.
  • Compatibility: Suitable for salt and sea water applications.
Technical Features:
  • Low pressure drop across the system.
  • Optional Smart Touchscreen Controller and Booster Pump available.
  • Equipped with temperature and flow sensor ports.
  • Can be mounted on the floor or wall.
Performance Data:
  • Pressure drop and flow rate data are provided for each model, indicating efficient operation under various conditions.
  • Heat output varies with temperature differential (∆T), with detailed performance metrics provided for ∆T ranging from 15°C to 70°C.
Physical Dimensions and Weight:
  • Dimensions and weights vary by model, with detailed specifications provided for each.
Contact Information: For sales and inquiries, contact Elecro at [email protected] or +44 (0) 1438 749474.
See more

Catalog excerpts

G2 MULTI TUBULAR HEAT EXCHANGER-1

G2 MULTI TUBULAR HEAT EXCHANGER The unique design and robust construction of the G2 Heat Exchanger offers an unrivalled heat transfer surface area, making it one of the most efficient products on the market. FEATURES • Four models ranging from 30-kW to 122-kW • Titanium tube bundle • BS 316L Stainless Steel primary casing • With optional Smart Touchscreen Controller and Booster Pump • Salt and sea water compatible • Temperature and flow sensor port • Floor or wall mountable TECHNICAL DRAWINGS PRESSURE DROP PRESSURE DROP PRIMARY CIRCUIT PRESSURE (BAR) Unit 11, Gunnels Wood Park, Stevenage, Hertfordshire SG1 2BH [email protected] | +44 (0) 1438

 Open the catalog to page 1
G2 MULTI TUBULAR HEAT EXCHANGER-2

PRESSURE DROP SECONDARY CIRCUIT PRESSURE (BAR) SPECIFICATIONS PRIMARY CIRCUIT FLOW TUBE BS 316L stainless steel tube WATER CONNECTIONS WORKING PRESSURE SECONDARY CIRCUIT FLOW TUBE Bundle of 37 titanium tubes WATER CONNECTIONS 1½” / 50mm st epped ABS unions for rigid pipe connection WORKING PRESSURE GROSS WEIGHT PRODUCT CODES STANDARD POWER OUTPUT STANDARD OUTPUT PRIMARY SECONDARY SECONDARY ∆T 15°C PRESSURE FLOW PRESSURE kW LOSS LOSS m³/h Bar Bar

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.