Product catalog summary
Facade Weatherproofing Systems

Breather Membrane System
  • Function: Provides waterproofing and vapor permeability, installed on the cold side of external insulation.
  • Installation: Vertical overlap of 150mm and horizontal overlap of 100mm. Fixed with double-sided adhesive/sealant tape and mechanical fixing.
  • Considerations: Detailed weatherproofing design required for each project. All perforations must be sealed, and installation should occur in dry conditions above 5ºC.

AVCL (Airtight Vapour Control Layer) System
  • Function: Acts as an airtight vapor barrier on the warm side of the back wall.
  • Installation: Similar overlap requirements as the breather membrane. Fixed on galvanized steel studs with double-sided adhesive/sealant tape.
  • Fire Performance: Must meet noncombustibility standards (Class A2-s1, d0).
  • Common Faults: Include unsealed perforations, lack of compatibility tests, and inadequate detailing.

Product Availability and Specifications
  • Effisus Breather FR System: Includes membranes and accessories with fire classification A2-s1,d0.
  • Effisus Vapour FR System: Offers high resistance to air and water penetration, with strong tensile strength.
  • Accessories: Include tapes and adhesives compatible with various substrates like concrete and aluminum.

Technical Support
  • Includes project-specific approaches, product specifications, weatherproofing design, and site support.
See more

Catalog excerpts

EFFISUS FACADE WEATHERPROOFING FIRE - Guidance-3

CONSULTANTS/ARCHITECTS FACADE WEATHERPROOFING - FIRE BREATHER / AVCL SYSTEMS BREATHER MEMBRANE SYSTEM System Function Waterproofing vapour permeable system. System Location Perimeter sealing It should be installed on top of the external insulation (cold side) protecting the entire facade composition. However and depending on the cladding brackets complexity (size/shape) it is acceptable that breather membrane systems be fixed on the top of the sheathing board. The weatherproofing design of the breather membrane systems should be done in detail and in project by project basis. Double-sided adhesive/sealant...

 Open the catalog to page 3
EFFISUS FACADE WEATHERPROOFING FIRE - Guidance-4

AVCL (AIRTIGHT VAPOUR CONTROL LAYER) SYSTEM System Function Airtight vapour barrier membrane. System Location Perimeter sealing AVCL should be located on the internal face (warm side) of the back wall and fixed on top of the vertical Galvanized Steel SFS Studs. The weatherproofing design of the AVCL membrane systems should be done in detail and project by project basis. Double side adhesive/sealant tape (thickness > 1,50mm) applied continuosly on the connections of ACVL membrane edges/end laps to concrete, aluminium or any other substrate allowing always the interface movement (AVCL/Windows frame;...

 Open the catalog to page 4
EFFISUS FACADE WEATHERPROOFING FIRE - Guidance-5

BREATHER/ AVCL SYSTEM ACCESSORIES DESIGN BREATHER MEMBRANE SYSTEM Application Overlaps Fixing Gypsum Sheathing Board, Calcium Silicate Boards, Cement Basis or similar Concrete or similar porous surfaces Galvanized Studs or similar metallic smooth surface Aluminium Foil (insulation) Perimeter Sealing Concrete or similar porous surfaces Aluminium EPDM Roofing Membrane Gas Membrane Nail/Screw Perforations Sealing Breather Membrane System AVCL Membrane System EPDM Membrane System Fully Envelope System Tested & All Compatibilities Checked It is necessary an accessory tested and developed for that...

 Open the catalog to page 5
EFFISUS FACADE WEATHERPROOFING FIRE - Guidance-6

PRODUCT AVAILABILITY

 Open the catalog to page 6
EFFISUS FACADE WEATHERPROOFING FIRE - Guidance-7

PRODUCT AVAILABILITY BREATHER / AVCL SYSTEMS (FIRE & WEATHERPROOFING DESIGN) A2 FIRE ENVELOPE SYSTEM • Effisus Breather FR membrane system • Effisus Vapour FR membrane system • Full range of accessories EFFISUS BREATHER FR SYSTEM System Class A (or Class 1) (ASTM E84) A2-s1,d0 (EN13501-1) Water vapour transmission properties (sd-value) (m) Tensile Strength MD/CD (N/50mm) Nail tear resistance MD/CD (N) a) The fire classification was obtained with Effisus accessories (double-sided adhesive tapes) tested as a system.

 Open the catalog to page 7
EFFISUS FACADE WEATHERPROOFING FIRE - Guidance-8

EFFISUS VAPOUR FR SYSTEM Vapour resistance (MNs/g) b) Water penetration Tensile Strength MD/CD (N/50mm) a) The fire classification was obtained with Effisus accessories (double-sided adhesive tapes and paste adhesive) tested as a system. b) Vapour resistance test result considering the vapour permeability of still air, in UK, 0.2 gm/MNS. EFFISUS ACCESSORIES SYSTEM X3 SYSTEM POSSIBILITIES Effisus 2Bond DS Tape Function Perimeter sealing; Sealing nail/screw perforations Function Fixing and overlaps membrane Substrates compatibility Concrete or similar porous surfaces; Aluminum Roofing membrane;...

 Open the catalog to page 8